ELVR - Analog and Digital Low Pressure Sensors Series
Table of Contents
Features & Applications . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Standard Pressure Ranges . . . . . . . . . . . . . . . . . . . . . . . . 2
Pressure Sensor Maximum Ratings . . . . . . . . . . . . . . . 2
Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . 2
Analog Output (5V) Specifications. . . . . . . . . . . . . . . 3
Analog Output (3V) Specifications. . . . . . . . . . . . . . . . 4
Digital Output (5V) Specifications .. . . . . . . . . . . . . . 5
Digital Output (3V) Specifications. . . . . . . . . . . . . . . . 6
Device Option Descriptions ................. . . . . . ...7
I
2
C Interface ................................. . . . . . ...8-9
SPI Interface .................................. . . . . 10-11
How to Order Guide........................ . . . . . . . . 12
Dimensional Package Drawings
Non-Barbed SIL, DIP and SMT . . . . 13-16
Barbed SIL,
DIP
and SMT . . . . . . . . . . . 1 7 - 2 0
Product Labeling................................21
Suggested Pad Layouts .......................21
Introduction
The ELVR Series Mini Analog and Digital Output Sensor is
based on All Sensors’ CoBeam
2 TM
Technology. This reduces
package stress susceptibility, resulting in improved overall
long term stability. The superior dual-die technology also
vastly improves position sensitivity compared to single die
devices. This technology breakthrough advances the state of
the art for piezoresistive pressure sensors beyond what has
been achieved for low pressure sensing using silicon based
strain technology.
The ELVR sensors can communicate directly with microcon-
trollers, eliminating the need for additional A/D converters.
ELVR series pressure sensors are available at 3V and 5V
supply voltage. The ELVR series provides a rapid update rate
at multiple resolutions. A wide range of miniature SIP and
DIP package options allows for flexible and space-saving
PCB-mounting. These calibrated and compensated sensors
provide accurate, stable output over a wide temperature
range. This series is intended for use with non-corrosive,
non-ionic working fluids such as air and dry gases. A pro-
tective parylene coating is optionally available for moisture/
harsh media protection for pressure ranges 10 inH2O and
above.
The ELVR Series is a direct replacement to First Sensors’
HCLA product line. Refer to the product web page for a
cross reference table:
https://www.allsensors.com/products/elvr-series
All Sensors
DS-0375 Rev A
Page 1
a
16035 Vineyard Blvd. Morgan Hill, CA 95037
p
408 225 4314
f
408 225 2079
e
www.allsensors.com
all sensors
ELVR Series Analog & Digital Pressure Sensors
Features
• Pressure Ranges from 2.5 mbar to 75 mbar
(1 to 30 inH2O)
• Precision ASIC Conditioning
• Analog Output with Digital I2C and SPI
Interface
• 3V and 5V Supply Voltage
Standard Pressure Ranges
Device
Operating Range
A
mbar
ELVR-L01D
ELVR-L05D
ELVR-L10D
ELVR-L20D
ELVR-L30D
ELVR-L01G
ELVR-L05G
ELVR-L10G
ELVR-L20G
ELVR-L30G
± 2.5
± 12.5
± 25
± 50
± 75
2.5
12.5
25
50
75
inH2O
±1
±5
± 10
± 20
± 30
1
5
10
20
30
Differential
Proof Pressure
mbar
250
500
500
500
500
250
500
500
500
500
inH2O
100
201
201
201
201
100
201
201
201
201
Differential
Burst Pressure
mbar
750
750
750
1250
2000
750
750
750
1250
2000
inH2O
301
301
301
502
803
301
301
301
502
803
p
408 225 4314
a
16035 Vineyard Blvd. Morgan Hill, CA 95037
e
www.allsensors.com
f
408 225 2079
Applications
• Medical
• Industrial
Note A: Operating range in inH2O is expressed as an approximate value. ELVR series is calibrated to mbar pressure units.
Pressure Sensor Maximum Ratings
Supply Voltage (Vs)
Analog-Output Current
Sink
Source
Common Mode Pressure
1 mA
1 mA
2000 mbar / 803 inH2O
2.7 to 5.5 Vdc
Environmental Specifications
Temperature Ranges
Compensated:
Commercial
Industrial
0°C
to 70°C
-20°C to 85°C
-25°C to 85°C
-40°C to 125°C
0 to 95% RH
Operating
Storage
Humidity Limits (non condensing)
SMT Assembly Specifications
Average preheating temperature gradient
Soak Time
Time above 217°C
Time above 230°C
Time above 250°C
Peak Temperature
Cooling Temperature Gradient
2.5 K/s
ca. 3 min
50 s
40 s
15 s
260°C
-3.5 K/s
Equivalent Circuit
I2C
+Vs
Vout
SCL
SDA
GND
See package drawings for pinouts.
SPI
+Vs
MISO
CLK
SS
MOSI
GND
Vout
All Sensors
DS-0375 Rev A
Page 2
Table of Contents
all sensors
Performance Characteristics for ELVR Series Amplified Low Pressure Sensors
All parameters are measured at
5.0 volt
excitation and 25°C unless otherwise specified. Pressure measurements
are with positive pressure applied to PORT B
Analog Performance Characteristics
Parameter
Full Scale Span (FSS)
Full Scale Output (FSO)
Min Pressure
Max Pressure
Span Temperature Shift
L01x
L05x though L30x
Offset Voltage @ zero differential pressure
LxxD
LxxG
Offset Temperature Shift
L01x
L05x
L10x through L30x
Offset Warm-up Shift
L01x
L05x thorugh L30x
Offset Long Term Drift (one year)
L01x
L05x thorugh L30x
Linearity, Hysteresis error (all products)
Response Delay
D/A Resolution
Current Consumption (no load)
-
-
-
-
-
-
±15
±5
±0.05
0.5
-
5.0
-
-
±0.25
-
11
-
mV
mV
%FSS
ms
bit
mA
-
-
4
1
-
6
-
-
±10
±5
-
-
mV
mV
3
3
-
-
-
-
-
-
±1.5
±1
±0.5
%FSS
%FSS
%FSS
2
2
2
2.15
0.15
2.25
0.25
2.35
0.35
V
V
-
-
-
-
-
-
±2
±1
%FSS
%FSS
2
2
0.25
4.25
V
V
Minimum
3.9
Nominal
4.0
Maximum
4.1
Units
V
Specification
Notes
5
-
Specification Notes
Note 1:
For any pressure applied the output response time to reach 90% of pressure applied.
Note 2:
Shift is relative to 25°C between standard or industrial compensated temperature
range endpoints.
Note 3:
Shift is within the first hour of excitation applied to the device.
Note 4:
Measured at one-half full scale rated pressure using best straight line curve fit.
Note 5:
The span is the algebraic difference between full scale output voltage and the offset voltage.
Note 6:
Parameter is characterized and not 100% tested.
ELVR Series Analog & Digital Pressure Sensors
Page 3
Table of Contents
Performance Characteristics for ELVR Series Amplified Low Pressure Sensors
All parameters are measured at
3.0 volt
excitation and 25°C unless otherwise specified. Pressure measurements
are with positive pressure applied to PORT B
Analog Performance Characteristics
Parameter
Full Scale Span (FSS)
Full Scale Output (FSO)
Min Pressure
Max Pressure
Span Temperature Shift
L01x
L05x though L30x
Offset Voltage @ zero differential pressure
LxxD
LxxG
Offset Temperature Shift
L01x
L05x
L10x through L30x
Offset Warm-up Shift
L01x
L05x thorugh L30x
Offset Long Term Drift (one year)
L01x
L05x thorugh L30x
Linearity, Hysteresis error (all products)
Response Delay
D/A Resolution
Current Consumption
-
-
-
-
-
-
±5
±5
±0.05
0.5
-
5
-
-
±0.25
-
11
-
mV
mV
%FSS
ms
bit
mA
-
-
4
1
-
6
-
-
±10
±5
-
-
mV
mV
3
3
-
-
-
-
-
-
±1.5
±1
±0.5
%FSS
%FSS
%FSS
2
2
2
1.15
0.15
1.25
0.25
1.35
0.35
V
V
-
-
-
-
-
-
±2
±1
%FSS
%FSS
2
2
0.25
2.25
V
V
Minimum
1.9
Nominal
2.0
Maximum
2.10
Units
V
Specification
Notes
5
-
All Sensors
DS-0375 Rev A
Page 4
Table of Contents
a
16035 Vineyard Blvd. Morgan Hill, CA 95037
p
408 225 4314
f
408 225 2079
e
www.allsensors.com
all sensors
Performance Characteristics for ELVR Series Amplified Low Pressure Sensors
All parameters are measured at
5.0 volt
excitation and 25°C unless otherwise specified. Pressure measurements
are with positive pressure applied to PORT B
Digital Performance Characteristics in Decimal
Parameter
Full Scale Span (FSS)
Full Scale Output (FSO)
Min Pressure
Max Pressure
Span Temperature Shift
L01x
L05x though L30x
Offset Voltage @ zero differential pressure
LxxD
LxxG
Offset Temperature Shift
L01x
L05x
L10x through L30x
Offset Warm-up Shift
L01x
L05x thorugh L30x
Offset Position Sensitivity (±1 g)
L01x
L05x thorugh L30x
Offset Long Term Drift (one year)
L01x
L05x thorugh L30x
Linearity, Hysteresis error (all products)
Response Delay
A/D Resolution
Current Consumption
-
-
-
-
-
66
33
±0.05
0.5
12
5
-
-
-
-
±0.25
Decimal
Decimal
%FSS
ms
bit
mA
-
-
4
1
-
6
-
-
99
33
-
-
Decimal
Decimal
-
-
-
-
66
33
-
-
Decimal
Decimal
3
3
-
-
-
-
-
-
±1.5
±1
±0.5
%FSS
%FSS
%FSS
2
2
2
14090
983
14745
1638
15400
2294
Decimal
Decimal
-
-
-
-
-
-
±2
±1
%FSS
%FSS
2
2
1638
27852
Decimal
Decimal
5
5
Minimum
-
Nominal
26214
Maximum
-
Units
Decimal
Specification
Notes
2
ELVR Series Analog & Digital Pressure Sensors
Page 5