Technical Data Sheet
RPC-N
50
Ω
Attenuator
Plug/Jack
05AS122-K03S3
Dieses Dokument ist urheberrechtlich geschützt
●
This document is protected by copyright
●
Rosenberger Hochfrequenztechnik GmbH & Co. KG
All dimensions are in mm; tolerances according to ISO 2768 m-H
Interface
According to
IEC 61169-16
Documents
Application note
AN001 “Calibration Services”
Documentation
This Part is delivered with:
•
USB Stick
o
S2p data file and uncertainty data file of the reference measurement values
o
Calibration Certificate as PDF file.
•
Calibration Certificate
Details see ”Declaration of calibration” options.
RF_35/09.14/6.2
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : info@rosenberger.de
Page
1/3
Technical Data Sheet
RPC-N
50
Ω
Attenuator
Plug/Jack
05AS122-K03S3
Material
Brass
CuBe
Stainless steel
Stainless steel
PPE
Al
2
O
3
Plating
Gold, min. 1.27 µm, over nickel
Gold, min. 1.27 µm, over nickel
Passivated
Passivated
Material and plating
Connector parts
Center conductor - plug
Center conductor - jack
Outer conductor
Coupling nut
Dielectric
Substrate
Dieses Dokument ist urheberrechtlich geschützt
●
This document is protected by copyright
●
Rosenberger Hochfrequenztechnik GmbH & Co. KG
Electrical data
Frequency range
DC Resistance
Power handling
DC to 18 GHz
50
Ω
≤
0.5 W
Electrical data (typical)
Return loss
≥
32 dB, DC to 4 GHz
≥
26 dB, 4 GHz to 12.4 GHz
≥
23 dB, 12.4 GHz to 18 GHz
3 dB
±
0.3 dB, DC to 8 GHz
3 dB
±
0.5 dB, 8 GHz to 12.4 GHz
3 dB
±
0.8 dB, 12.4 GHz to 18 GHz
Attenuation
Mechanical data
Mating cycles
Maximum torque
Recommended torque
Gauge - plug
Gauge - jack
≥
500
1.70 Nm
1.10 Nm
5.28 mm to 5.32 mm
5.22 mm to 5.26 mm
Electrical verification standard
This Attenuator is designed as an electrical verification standard. Reference measurement values
(calibration results) for transmission and reflection are included. Connected to a calibrated VNA the actual
measured transmission and reflection values can be compared to the reference measurement values and
the quality of the VNA calibration can be evaluated.
Environmental data
Operating temperature range
2
Rated temperature range of use
Storage temperature range
RoHS
1
2
1
+ 20 °C to +26 °C
0 °C to +50 °C
- 40 °C to +85 °C
compliant
Temperature range over which the reference measurement values are applicable.
This range is underneath and above the operating temperature range, within the attenuator is fully functional
and could be used without damage.
RF_35/09.14/6.2
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : info@rosenberger.de
Page
2/3
Technical Data Sheet
RPC-N
50
Ω
Attenuator
Plug/Jack
05AS122-K03S3
Declaration of calibration options
Factory Calibration
Standard delivery for this verification standard includes a Factory Calibration. The Calibration Certificate
issued reports individual transmission and reflection calibration results traceable to national / international
standards. A S2p data file with the reference measurement values and the measurement uncertainties in
electronic format are included.
Accredited Calibration
Optional this verification standard can be delivered with an Accredited Calibration (DAkkS) having the
highest confidence in the traceability. The DAkkS Calibration Certificate issued reports individual
transmission and reflection calibration results traceable to national / international standards. A S2p data file
with the reference measurement values and the measurement uncertainties in electronic format are
included. The measurement uncertainties are smaller than in a Factory Calibration.
For further, more detailed information see application note AN001 on the Rosenberger homepage.
Dieses Dokument ist urheberrechtlich geschützt
●
This document is protected by copyright
●
Rosenberger Hochfrequenztechnik GmbH & Co. KG
Calibration interval
Recommendation
12 months
Packing
Standard
Weight
1 pce in box
67 g/pce
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
Draft
Marion Striegler
Date
26.01.18
Approved
Lars Ramtke
Date
28.03.18
Rev.
a00
Engineering change number
18-0190
Name
Marion Striegler
Date
28.03.18
RF_35/09.14/6.2
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : info@rosenberger.de
Page
3/3
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Rosenberger
:
05AS122-K03S3