EEWORLDEEWORLDEEWORLD

Part Number

Search

VI-PJ013-CXY

Description
Isolated DC/DC converter VI-PJ013-CXY
CategoryThe power supply    DC/DC converters    Isolated DC/DC converter   
File Size719KB,8 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Download Datasheet Parametric View All

VI-PJ013-CXY Online Shopping

Suppliers Part Number Price MOQ In stock  
VI-PJ013-CXY - - View Buy Now

VI-PJ013-CXY Overview

Isolated DC/DC converter VI-PJ013-CXY

VI-PJ013-CXY Parametric

Parameter NameAttribute value
MakerVICOR
Product CategoryIsolated DC/DC converter
Number of outputs2 Output
Input voltage12 VDC
Output voltage—channel 112 VDC
Output voltage—channel 224 VDC
Insulation voltage3 kV
Installation styleChassis Mount
length65.532 mm
width124.5 mm
high15.748 mm
industryIndustrial
productIsolated
size65.532 mm x 124.5 mm x 15.75 mm
Maximum operating temperature+ 100 C
Minimum operating temperature- 25 C
MegaMod™ &
MegaMod Jr.™ Family
25 to 600 Watts DC-DC Converters Single, Dual, Triple Output Chassis Mount
Features & Benefits
RoHS compliant (VE versions)
Inputs: 10 to 400V
DC
Any output, 1 to 95V
DC
cULus, cTÜVus, CE Marked
80 – 90% Efficiency (Typical)
Up to 27 W/In3
1 Up:
2.58” x 2.5” x 0.62” (Junior)
4.9” x 2.5” x 0.62” (Full Size)
2 Up:
2.58” x 4.9” x 0.62” (Junior)
4.9” x 4.9” x 0.62” (Full Size)
3 Up:
2.58” x 7.3” x 0.62” (Junior)
4.9” x 7.3” x 0.62” (Full Size)
Low noise ZCS power architecture
Booster versions available for
expanded output power –
full size only (add B to part number
Example: VI-LBxx-xx)
Configuration Chart
Substitute VE– for VI– for RoHS compliant versions
Full-Size Modules – MegaMod
Configuration
Single Output
VI-L
-
VI-M
-
F
A
A
F A
VI-N
FF AA
-
F
FF AA
F A
F
Dual Output
A
VI-P
FF AA
-
F A
Junior-Size Modules – MegaMod Jr
# of
Modules Configuration
1
2
3
2
3
3
F FA
F A
F
Triple Output
AA
FF A
F A
A
Output
Power
50 – 200W
100 – 400W
300 – 600W
100 – 400W
F
F
F
A
F
F
A
A
A A
F F
Output
Power
25 – 100W
F
A
# of
Modules
1
Single Output
VI-LJ
-
Dual Output
VI-PJ
-
F
A
F
A
50 – 200W
2
VI-Q
A
F A
Triple
F F F A A
Output
-
-
150 – 600W
150 – 600W
A
VI-R
F F F A A
A
F A
A
VI-RJ
-
F
A A
F F
75 – 300W
3
A
F F AF A A
F A
Input
F
Voltage
Nominal
0 = 12V
[b][c]
V = 24V
[b][c]
1 = 24V
[d]
W = 24V
[d]
2 = 36V
3 = 48V
N = 48V
4 = 72V
T = 110V
5 = 150V
6 = 300V
7 = 150/300V
Max. Output
Per Module
(1)
(2)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
10 – 20V
10 – 36V
21 – 32V
18 – 36V
21 – 56V
42 – 60V
36 – 76V
55 – 100V
66 – 160V
100 – 200V
200 – 400V
100 – 375V
Input Range
Full Power
Maximum Power
(see chart below)
MegaMod
(4)
(2)
(8)
(8)
(6)
(10)
(10)
(9)
(8)
(9)
(10)
(5)
MegaMod Jr.
(1)
(11)
(6)
(6)
(1)
(6)
(5)
(6)
(5)
(6)
(6)
>7.5V
Outputs
75W
75W
75W
100W
100W
150W
150W
200W
200W
50W
F F FF AA
A
F A A
Low Line
Transient
[a]
75% Max Power
n/a
n/a
18V
n/a
18V
36V
n/a
45V
n/a
85V
170V
90V
22
n/a
36
n/a
60
72
n/a
110
n/a
215
425
n/a
Output
Voltage
Z
Y
0
X
W
V
T
R
M
1
P
2
N
3
L
J
K
4
H
F
D
B
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
2V
3.3V
5V
5.2V
5.5V
5.8V
6.5V
7.5V
10V
12V
13.8V
15V
18.5V
24V
28V
36V
40V
48V
52V
72V
85V
95V
A
Product Highlights
Vicor’s MegaMod and MegaMod Jr.
Families of single, dual and triple output
DC-DC converters provide power system
designers with cost effective, high
performance, off-the-shelf solutions to
applications that might otherwise require a
custom supply.
Incorporating standard VI-200 or VI-J00
Family converters in rugged, chassis mount
packages, MegaMod and MegaMod Jr.’s
can be ordered with single, dual or triple
outputs, having a combined output power
of up to 600W. Totally isolated outputs
eliminate efficiency penalties and output
interaction problems.
5 – 7.5V
Outputs
50W
50W
[e]
75W
75W
100W
[f]
100W
150W
150W
200W
50W
(1)
<5V
Outputs
10A
15A
15A
20A
20A
30A
30A
40A
40A
10A
[a]
[b]
[c]
[d]
[e]
[f]
Transient voltage for 1 second.
Single output configurations of 225W are limited to +55°C ambient and are available by special order.
Dual and triple output configurations totaling 225W are limited to +55°C ambient.
Single, dual, and triple output configurations totaling 450W are limited to +55°C.
7.5V output is 75W
6.5V and 7.5V output is 75W
Product Grade Temperature (°C)
MegaMod
E
C
I
M
=
=
=
=
–10 to +85
–25 to +85
–40 to +85
–55 to +85
Output Power/Current
MegaMod
MegaMod Jr.
V
OUT
5V V
OUT
< 5V V
OUT
5V V
OUT
< 5V
Y
=
X
=
W
=
V
=
U
=
50W
75W
100W
150W
200W
Y
=
X
=
W
=
V
=
U
=
10A
15A
20A
30A
40A
Z
=
Y
=
X
=
W
=
25W
50W
75W
100W
Z
= 5A
Y
= 10A
X
= 15A
W
= 20A
MegaMod Jr.
–10 to +100
–25 to +100
–40 to +100
–55 to +100
For on-line product configuration visit:
MegaMod / MI-MegaMod DC-DC
Converters Configurator
Refers to Baseplate Temperature
Output Power/Current
V
OUT
5V
W
V
U
S
Q
=
=
=
=
=
100W
150W
200W
300W
400W
V
OUT
< 5V
W
V
U
S
Q
=
=
=
=
=
20A
30A
40A
60A
80A
Output Power/Current
V
OUT
5V
S
= 300W
P
= 450W
M
= 600W
V
OUT
< 5V
S
= 60A
P
= 90A
M
= 120A
MegaMod™ & MegaMod Jr.™ Family
Page 1 of 7
Rev 2.3
09/2016
vicorpower.com
800 927.9474
51 MCU falling edge trigger
Hey guys, why can't my program be triggered by the falling edge? Please help me change it to the falling edge trigger. Thank you very much #include#define uchar unsigned char #define uint unsigned int...
clock飞天 51mcu
Last few hours: Seek help from power experts Vicor + Pulse load power supply design method white paper download gift
{:1_97:}Yes, today is the last day (April 25) for Vicor's white paper downloads with prizes. If you want to ask questions or learn about pulse power supply design solutions, don't miss it~ [size=5][co...
EEWORLD社区 Power technology
NIOS automatic operation (paid answer)
Nios (a single qsys core) is debugged online normally, no problem, add other code, resource usage is 52%, nios core always runs away, program runs wrong. Which big guy has encountered similar phenomen...
PBGG FPGA/CPLD
Today's live broadcast: Battery management chip solution design and precautions
Live Topic: Battery Management Chip Solution Design and PrecautionsLive Time: 10:00-11:30 this morningContent Introduction: This seminar will introduce you to the design of Datang NXP's battery manage...
EEWORLD社区 Power technology
[Repost] 7 PCB layout principles, good PCB design depends on it
(1) It is best to place components on one side. If you need to place components on both sides, place pin-type components on the bottom layer (BottomLayer). It is best to place components on one side. ...
皇华Ameya360 Power technology
How to choose electromagnetic relay
[align=left][font="][size=4][color=#0000ff]1. Select the rated working voltage and rated working current [/color][/size][/font][/align][align=left][color=rgb(34, 34, 34)][font="]When selecting an elec...
tiankai001 Integrated technical exchanges

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号