The REC10-xxxxSRW/DRW-series offer single and dual regulated outputs in a DIP24 package
with 2kV or 3kV isolation options and are suitable for higher power industrial or medical
applications. Remote on/off control is standard and SMD pinning is offered with the /SMD option.
The converters can deliver 150% rated power for short periods of time to cope with applications
with large capacitive loads or high start up currents.
10 Watt
DIP24
&
SMD
Single
&
Dual
Output
Selection Guide
Part
Number
REC10-xx3.3SRW/H*/A/M
REC10-xx05SRW/H*/A/M
REC10-xx12SRW/H*/A/M
REC10-xx15SRW/H*/A/M
REC10-xx05DRW/H*/A/M
REC10-xx12DRW/H*/A/M
REC10-xx15DRW/H*/A/M
REC10-xx3.3SRWZ/H*/A/M
REC10-xx05SRWZ/H*/A/M
REC10-xx12SRWZ/H*/A/M
REC10-xx15SRWZ/H*/A/M
REC10-xx05DRWZ/H*/A/M
REC10-xx12DRWZ/H*/A/M
REC10-xx15DRWZ/H*/A/M
Input
Voltage
(VDC)
9-18, 18-36, 36-75
9-18, 18-36, 36-75
9-18, 18-36, 36-75
9-18, 18-36, 36-75
9-18, 18-36, 36-75
9-18, 18-36, 36-75
9-18, 18-36, 36-75
9-36, 18-75
9-36, 18-75
9-36, 18-75
9-36, 18-75
9-36, 18-75
9-36, 18-75
9-36, 18-75
Output
Voltage
(VDC)
3.3
5
12
15
±5
±12
±15
3.3
5
12
15
±5
±12
±15
Output
Current
(mA)
2000
2000
833
667
±1000
±416
±333
2000
2000
833
667
±1000
±416
±333
Efficiency Max. Cap.
Load
(%)
84-85
86-87
85-86
85-86
84
86
86
84
86
85
85
83
85
85
2200µF
2200µF
470µF
220µF
±1000µF
±220µF
±100µF
2200µF
2200µF
470µF
220µF
±1000µF
±220µF
±100µF
2011/65/EU
6/6
RoHS
E224736
EN-60950-1 Certified
EN-60601-1 Certified
UL-60950-1 Certified
REC10
* Standard is /H2 for 2kVDC isolation,
2:1
use /H3 for 3kVDC Isolation (not SMD)
xx = 9-18Vin = 12,
* add suffix "/X2" for pinning options, see next page. xx = 18-36Vin = 24,
* add suffix "/SMD" for SMD package, e.g.
xx = 36-75Vin = 48
REC10-2405SRW/H2/A/M/SMD
4:1
xx = 9-36Vin = 24,
xx = 18-75Vin = 48
Specifications
(
measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Input Voltage Range
Input Filter
Output Voltage Accuracy
Line Voltage Regulation (VL to VH at full load)
Load Voltage Regulation
(25% to 100% full load )
Single
Dual
2:1 & 4:1
PI Network
±1.5% max.
±0.5% max.
±0.5% max.
±1.2% max.
±5% max.
100mVp-p max.
300ms typ.
400kHz typ.
see Selection Guide
0%
continued on next page
www.recom-power.com
REV: 0/2015
Refer to Application Notes
E-163
**Any data referred to in this datasheet are of indicative nature and
based on our practical experience only. For further details, please refer
to our Application Notes.
Cross Regulation (100%: 25% to 100% full load )
Output Ripple and Noise (with 100n output capacitor and 20MHz BW)
Start-up time
Operating Frequency (Full Load)
Efficiency at Full Load
Minimum Load
ECONOLINE
DC/DC-Converter
Input Surge Voltage (100ms max.)
REC10-S_DRW(Z)/H*/A/M
Series
36VDC
50VDC
100VDC
2000VDC
1000VAC / 60Hz
3000VDC
1500VAC / 60Hz
1200pF typ.
1 GΩ min.
Output Power (%)
Specifications
(
measured at TA = 25°C, nominal input voltage, full load and after warm-up)
12V Input
24V Input
48V Input
H2-Suffix and SMD (tested for 1 second)
(rated for 1 minute**)
H3-Suffix
(tested for 1 second)
(rated for 1 minute**)
Derating-Graph
(Ambient Temperature)
2:1 Converters
100
80
60
40
20
0
-40
0
50
100
150
Isolation Voltage
Safe Operating Area
Isolation Capacitance
Isolation Resistance
Overload Protection
Short Circuit Protection
Operating Temperature Range
(free air convection)
Remote On/Off
Storage Temperature Range
Temperature Coefficient
Relative Humidity
Case Material
Thermal Impedance
Maximum Case Temperature
Vibration
Package Weight
Packing Quantity
MTBF (+25°C)
(+71°C)
4:1
2:1
DC/DC ON
DC/DC OFF
150% typ.
Continuous, Auto Restart
-40°C to +71°C (see Graph)
-40°C to +81°C (see Graph)
Open or 3.5V<Vr<12V
Short or 0V<Vr<1.2V
-55°C to +105°C
±0.05% max.
95% RH
Nickel Plated Metal with Non-Conductive Base
Natural convection
15°C/W
100°C
10-55Hz, 2G, 30mins along X,Y & Z
18g
15 pcs per Tube
using MIL-HDBK 217F
using MIL-HDBK 217F
1000 x 10
3
hours
>250 x 10
3
hours
81
Operating Temperature °C
4:1 Converters
100
Safe Operating Area
4:1
Output Power (%)
80
60
40
20
0
-40
0
}
Detailed Information see
Application Notes chapter "MTBF"
REC10
Certifications
EN General Safety
UL General Safety
EN Medical Safety
Report: SPCLVD1211033-2
Report: E224736
Report: MDD12060585 + RM1206085
EN60950-1:2006 + A12:2011
UL 60950-1 1st Ed.
C22.2 No. 60950-1-03
IEC/EN 60601-1 3rd Edition
Medical Report + ISO14971 Risk Assessment
50 71 90
150
Operating Temperature °C
Typical Characteristics
REC10-1205SRW/H2/A/M (/SMD)
REC10-1212SRW/H2/A/M (/SMD)
Efficiency / Load (Nominal Vin)
1212S
1205S
90
88
86
84
82
80
78
76
74
72
70
Efficiency VS Input Voltage
1205
100
80
Efficiency %
60
40
20
0
1212
0%
20%
80%
60%
Total Output current (%)
40%
100%
Efficiency (%)
9
10
12
14
16
18
Input Voltage (V)
Note: Refer to Application Notes for EMC Class B Filter suggestion
E-164
REV: 0/2015
www.recom-power.com
ECONOLINE
DC/DC-Converter
Package Style and Pinning (mm)
REC10-S_DRW(Z)/H*/A/M
Series
24 PIN DIP Package - Available with /H2 and /H3 Options
32.00
10.20
4.1
+0.25 /-0.5
2.03
0.50
20.30
Pin Connections DIP24
Pin #
1
2
Single
CTRL
–Vin
–Vin
NC
NC
+Vout
– Vout
+Vin
+Vin
Single/X2
No Pin
–Vin
–Vin
No Pin
NC
+Vout
–Vout
+Vin
+Vin
Dual
CTRL
–Vin
–Vin
Com
–Vout
+Vout
Com
+Vin
+Vin
15.24
3
9
11
14
16
22
23
2.54
Top View
Recommended Footprint Details
1.00 ø+0.15/0
1 2 3
Bottom View
23 22
16
14
9
11
NC = No Connection
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
2.54
REC10
24 PIN SMD Package- Only available with /H2 Option
32.00
31.40
11.20
10.90
3.81
6.35
20.30
25.40
Pin Connections DIP24 SMD
Pin #
2.54
1
2
3
9
11
Pin area
0.1 x 0.50
1 2 3 4 5
19.90
Single
CTRL
–Vin
–Vin
NC
NC
+Vout
– Vout
+Vin
+Vin
Dual
CTRL
–Vin
–Vin
Com
–Vout
+Vout
Com
+Vin
+Vin
NC
NC
Recommended Footprint Details
0.50
9 10 11 12
2.54
1.54
2.03
14
16
22
23
4,5,10,12
23.40
Bottom View
24 23 22 21 20
16 15 14 13
26.67
24.64
1
Top View
13,15,20,21,24
NC = No Connection
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
11 x 2.54
27.94
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
I used the BTS7960 chip to form an H-bridge to drive a high-current motor, and the working voltage is 12V. [color=#ff0000]1. I started to let the motor rotate continuously; [/color] [color=#ff0000]2. ...
Live Replay: The best assistant for human-computer interaction interface and machine vision applications - Renesas Electronics RZ/G, RZ/A and RZ/V SoC series : https://training.eeworld.com.cn/course/5...
[size=4][color=#000000][backcolor=white] The difference between a processor and a single-chip microcomputer: a processor is a core, and a single-chip microcomputer is an embedded small system composed...
This article records the capture function of the timer1. Can capture square waves of any length, test millisecond and second level capture is no problem
2. A 10s timeout (TIMER_CAP_TIMEOUT) is added t...
If you’ve ever heard the piercing alarms of a patient monitor in an intensive care unit (ICU) or in a hospital scene in a TV show or movie, you may remember that these alarms have specific patterns th...
In the real world, water quality testing is closely related to human life.With the country's investment in environmental protection, the demand for analysis, management, protection and testing of indu...
As the wave of automation continues to advance,
the demand for
robots
in factory production lines
is increasing day by day. In recent years, ABB, a global robot giant, has kept up with the p...[Details]
How to use a multimeter? This is a small problem for many novice electricians or home users. They have a multimeter but don't know how to use it. Today, let's talk about the functions of a multimeter...[Details]
InvenSense sensor partners enable efficient prototyping and development for wearables, hearables, healthcare devices, drones, other IoT and robotics applications
Partner...[Details]
LED
(Light
Emitting
Diode) is a new type of competitive solid light source in the 21st century. Compared with traditional light sources, it has the advantages of small size, long life,...[Details]
0 Preface Integrated circuit testers can be used to measure the quality of integrated circuits and are widely used in electronic laboratories. In actual use, it is found that some testers produce...[Details]
ARM 's RAM includes static RAM, dynamic RAM, and TCM---tightly coupled memory (TCM: Tightly Coupled Memories).
TCM is a fixed size RAM, tightly coupled to the processor core, providing performance c...[Details]
Applications:
The field of high voltage and high power motor variable frequency speed regulation.
challenge:
The unit series high-voltage inverter uses several low-voltage power units in se...[Details]
Following the Dragon Scale Armor battery solution, Honeycomb Energy uses dagger battery cell + flying stack technology as the core to fully support the innovation and upgrade of battery fast charging...[Details]
According to foreign media reports, Taiwan-based OToBrite Electronics announced the development of a Blind Spot Information System (BSIS) for large commercial vehicles using visual AI. Optimin said t...[Details]
my country successfully launched the 52nd and 53rd Beidou navigation satellites at the Xichang Satellite Launch Center, completing the deployment of the core constellation of the Beidou-3 global syst...[Details]
Ground resistance tester is a resistance measuring device, mainly used for measuring ground resistance, soil resistivity, ground voltage, AC current, leakage current of power, telecommunication, mete...[Details]
Earlier this year, Samsung officially announced that it would launch its next-generation flagship chip Exynos equipped with an AMD graphics processor. Recently, AMD revealed more details about this p...[Details]
0 Introduction
With the rapid development of computers, the virtual instrument technology proposed by the National Instruments Company NI (National Instruments) has triggered a major change in the t...[Details]
A multimeter is a common measuring tool used by electricians. It can be used to measure parameters such as voltage, current, and resistance. A soft starter is a device used to start a motor. It can...[Details]