RoHS Compliant
ALUMINIUM ELECTROLYTIC CAPACITOR
FEATURES
◆
◆
◆
◆
High value of CV range
Load life of 2000 hours at 85°C
Standard series for general purpose
Applications for TV, video, audio, office and home appliances, etc.
SR Series
OUTLINE
mm
D
F
d
5
2.0
6.3
2.5
8
3.5
10
5.0
0.6
13
16
7.5
0.8
18
20
22
25
12.5
1
10.5
0.5
SPECIFICATIONS
Items
Capacitance Tolerance
(120Hz, 25°C)
Rated Working Voltage Range
Operation Temperature
6.3 ~ 100Vdc
-40°C ~ +85°C
(After 2 minutes applying the DC working voltage)
Leakage Current (25°C)
◆
Characteristics
±
20% (M)
160 ~ 450Vdc
-25°C ~ +85°C
(After 5 minutes applying the DC working voltage)
I
≤
0.03CV + 10 (u A)
C : Rated Capacitance (u F)
35
44
35
40
50
40
50
63
50
63
79
63
100
125
100
◆
I
≤
0.01CV or 3 (u A)
I : Leakage Current (u A)
W.V.
6.3
8
6.3
10
13
10
16
20
16
◆
V : Working Voltage (V)
200
250
200
250
300
250
350
400
350
400
450
400
450
500
450
25
32
25
160
200
160
Surge Voltage (25°C)
S.V.
W.V.
Dissipation Factor (120Hz, 25°C)
◆
tan
δ
0.25 0.20 0.17 0.15 0.12 0.12 0.10 0.10 0.10 0.15 0.15 0.15 0.20 0.20 0.20
For capacitance exceeding 1000
u
F, add 0.02 per increment of 1000
u
F
W.V.
6.3
4
10
10
4
8
16
3
6
25
3
4
35
2
3
40
2
3
50
2
3
63
2
3
100
2
3
160
3
4
200
3
4
250
3
4
350
6
6
400
6
6
450
6
6
- 25°C / + 25°C
Temperature Characteristics
- 40°C / + 25°C
◆
Impedance ratio at 120Hz
After 2000 hours application of WV at +85°C, the capacitor shall meet the following limits:
Capacitance Change
Load Test
tan
δ
Leakage Current
≤ ±
20% of initial value
≤
150% of initial specified value
≤
initial specified value
After 1000 hours, no voltage applied at +85°C, the capacitor shall meet the following limits:
Capacitance Change
Shelf Test
tan
δ
Leakage Current
≤ ±
20% of initial value
≤
150% of initial specified value
≤
200% of initial specified value