SUNON
SPECIFICATION FOR APPROVAL
CUSTOMER
DESCRIPTION
DIMENSIONS
MODEL
CUSTOMER
APPROVAL NO.
APPROVED BY
CUSTOMER
(AUTHORIZED)
:
: DC BRUSHLESS FAN
: 92X92X25 mm
: GF92251B2-000U-SE9
SUNON SPEC. NO. : D09032880G-00
:
:
SPEC.NO
DRAWN
D09032880G-00
05. 20. 2014
0
E11400070
Dolphin
5/20
CHECKED
Kiddy
Cindy
ISSUE DATE
APPROVED
Kelly
EDITION
REVISION DATE
E.SPEC
建準電機工業股½有限公司
SUNONWEALTH ELECTRIC MACHINE INDUSTRY CO., LTD.
TEL:886-7-8135888
NO. 30, LN. 296, XINYA RD., QIANZHEN DIST.,
FAX:886-7-8230505/8230606/8231010
KAOHSIUNG CITY 80673, TAIWAN (R.O.C)
E-mail: sunon@email.sunon.com.tw
URL:http://www.sunon.com
D.C.C.
2014.06.13
建 準 電 機
SUNONWEALTH
Page 1 of 16
II. SPECIFICATION
1. MECHANICAL CHARACTERISTIC
MOTOR DESIGN
BEARING SYSTEM
DIMENSIONS
MATERIALS OF FRAME
MATERIALS OF FAN BLADE
DIRECTION OF ROTATION
MOUNTING HOLES
WEIGHT
Single phase, 4-poles Brushless DC motor
Precision ball bearing system
See Page 6
Thermoplastic PBT of UL 94V-0
Thermoplastic PBT of UL 94V-0
Counter-clockwise viewed from front of fan blade
Diameter 4.3 mm in 8 holes
113 g
2. ELECTRIC CHARACTERISTIC
RATED VOLTAGE
RATED CURRENT
RATED POWER CONSUMPTION
OPERATING VOLTAGE RANGE
STARTING VOLTAGE
OPERATING TEMPERATURE RANGE
STORAGE TEMPERATURE RANGE
12 VDC
300 mA / MAX. 345 mA
3.60 WATTS / MAX. 4.14 WATTS
10.2~13.8 VDC
10.2 VDC (25 deg. C POWER ON/OFF)
-10 to + 70 deg. C
-40 to + 80 deg. C
D.C.C.
2014.06.13
建 準 電 機
SUNONWEALTH
Page 3 of 16
3. PERFORMANCE CHARACTERISTIC
RATED SPEED
AIR FLOW
STATIC PRESSURE
ACOUSTIC NOISE
AIR FLOW V.S. PRESSURE
INSULATION CLASS
INSULATION RESISTANCE
PLASTIC HOUSING
4200 RPM ± 10% at rated voltage
70.0 CFM
0.30 Inch-H
2
O
45.0 dB(A)
See Page 5
UL Class A
10M ohm at 500 VDC between internal stator and
lead wire (+)
DIELECTRIC STRENGTH
LIFE EXPECTANCY
PROTECTION
Applied AC 500 V for one minute or AC 600 V for 2
Seconds between housing and lead wire (+)
70,000 Hours at 40 deg. C, 65% humidity, 90% CL .
Automatic Restart
Note: In a situation where the fan is locked by an external
force while the electricity is on, an increase in coil temperature
will be prevented by temporarily turning off the electrical
power to the motor. The fan will automatically restart when
the locked rotor condition is released.
Polarity Protection
IP Class : IP68
According to IEC 529 (or IEC 34-5) IP standard, the average
temperature is 23~24°C and humidity is 67% RH for Dust Water Test.
The fan needs to be test and Spray Put in dust box for 8 hours for Dust
Test and be put in long period immersion of water for Spray Water
Test. After these 2 tests, which executing by regular standard, the fan
will be measured the performance is normal or not.
PS. There are different applicative environments and systems by
different customers, so please put the product in the most suitable
environment to measure the performances.
4. SAFETY
SAFETY
NO.
UL
E77551
CUR
E77551
TUV
CE
D.C.C.
2014.06.13
建 準 電 機
SUNONWEALTH
Page 4 of 16