Lineup includes models with self-diagnostic output to provide notification of failures and
unstable detection conditions, such as coil burnout.
•
Contributes to preventive maintenance to keep the line from stopping.
Reduced wiring, fewer resources, and low power consumption contribute to
environmentalism.
•
Wiring work and amount of copper wire used reduced to two thirds of that required for 3-wire models.
•
Current consumption drastically reduced to less than 10% (when a DC 2-wire model is compared with a DC 3-wire model).
3-Wire Models
Wide range of ambient operating temperatures:
−40°C
to 85°C (M8 to M30 models)
•
Suitable for low-temperature and high-temperature applications, which are troublesome for photoelectric sensors.
Lineup includes models with flexible cable (M8 to M30 models)
•
Reduced risk of disconnection in applications with moving parts.
2
E2E
E2E Guide to Selection by Purpose
Environment
Wide
operating
temperature range
−40
to 85°C
AC 2-wire: M12 to M30,
DC 3-wire: M8 to M30
−25
to 70°C
Models not listed above.
Resists the influence of surrounding metal
Shielded Models
Maintenance
Reducing stocked
models
NPN/PNP
output
DC 2-Wire Models
E2E-X@D@
AC/DC 2-Wire Models
E2E-X@T1
Smartclick Pre-wired
Connector Models
E2E-X@D@-M1TGJ-(U)/(US)
Pre-wired Connector
Models
E2E-X@D1-M1(G)J-(T)
Connector Models
E2E-X@D@-M1(G)
E2E-X@E@-M1
E2E-X@Y@-M1
AC/DC
Easy replacement
Reducing troubles
Higher oil resistance
Reinforced
Models
with
Oil-resistor
reinforced PUR cable
E2E-X@D@-U
Models
with
Oil-resistant PVC
cable
Robotics Cable Models
E2E-X@D1-R
E2E-X@E1-R
Models
with
a Different
Frequency (NO Models
only)
E2E-X@@15
Standard
Mounting to moving
parts
Robotics cable
Mutual interference
prevention
Miswiring measures
Load short-circuit
protection
DC 2-Wire Models
E2E-X@D@
DC 3-Wire Models
E2E-X@E@
DC 2-Wire
No-polarity
Models
E2E-X@D1-M1J-T
Diagnostic Models
E2E-X@D1S
No
polarity
Early discovery
of problems
Note:
Refer to
Models Not Listed in this Catalog
for Long Body Models, Transmission Couplers, and Power Couplers.
3
E2E
E2E Model Number Legend
E2E-
A B C D E F G
-
H I
-
J
-
K
-
L
No.
A
B
C
Classification
Appearance
Sensing distance
Shielding
Code
X
Number
R
Blank
M
B
C
D
E
F
T
Y
1
2
Blank
5
Blank
5
Blank
H
Connection method
M1
M3
Blank
G
I
Connector specifications
J
GJ
TJ
TGJ
J
DC 2-wire polarity
Blank
T
Blank
R
U
N
US
Letter M
M
Meaning
Remarks
Example:
1R5: 1.5 mm
D
Power supply and output
specifications
E
F
G
Form of output switching el-
ement
Oscillation frequency type
Self-diagnosis
Cylindrical (threaded)
Sensing distance (Unit: mm)
Indication of decimal point
Shielded Model
Unshielded Model
DC 3-wire PNP open-collector output
DC 3-wire NPN open-collector output
DC 2-wire polarity/no polarity
DC 3-wire NPN collector load built-in output
DC 3-wire PNP collector load built-in output
AC/DC 2-wire
AC 2-wire
Normally open (NO)
Normally closed (NC)
Standard frequency
Different frequency
No
Yes
Pre-wired
M12-size metal connector
M8-size metal connector
Connector Model
DC 3-wire and AC 2-wire, DC 2-wire with self-diagnosis output,
DC 2-wire with old pin arrangement
Connector Model
DC 2-wire with IEC pin arrangement
Pre-wired Connector Model
DC 3-wire and AC 2-wire, DC 2-wire with old pin arrangement
Pre-wired Connector Model
DC 2-wire with IEC pin arrangement
Pre-wired Smartclick Connector Model
DC 2-wire
Pre-wired Smartclick Connector Model
DC 2-wire with IEC pin arrangement
Polarity
No polarity
Standard PVC cable (oil resistant)
Flexible PVC cable (oil resistant)
Polyurethane cable (oil resistant and reinforced)
New model (Applies only to DC 2-wire pre-wired and shielded
models.)
UL-recognized model (Applies to DC 2-wire pre-wired models
and pre-wired connector models.)
Cable length (Unit: m) (Applicable to Pre-wired Models and Pre-
wired Connector Models.)
Whether D models have
polarity is defined by num-
ber
J.
Used to prevent mutual in-
terference.
K
Cable specifications
New model
L
Standard-certified model
M
Cable length
This is blank if the cable
specification in number
K
is R or U.
Example:
2M
0.3M
Note: The purpose of this model number legend is to provide understanding of the meaning of specifications from the model number.
Models are not available for all combinations of code numbers.
4
E2E
Ordering Information
2-Wire Models
Shielded DC 2-wire Models with No Self-diagnostic Output
[Refer to
Dimensions
on page 27.]
Appear-
ance
Sensing distance
Connection
method
Cable
specifications
Polar-
ity
M12 Pre-wired Smart-
PUR (increased
click Connector Mod-
oil-resistant)
els (0.3m)
PVC (oil-resistant)
PUR (increased
oil-resistant)
PVC (oil-resistant)
M12 Connector Mod-
els
M8 Connector Models
---
---
Yes
Opera-
Pin
tion
arrangement
mode
NO
1: +V, 4: 0 V
NC
NO
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NO
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
---
1: +V, 2: 0 V
1: +V, 4: 0 V
Applicable
connector
code
*2
H
G
Model
E2E-X2D1-M1TGJ-U 0.3M
E2E-X2D2-M1TGJ-U 0.3M
E2E-X2D1-M1TGJ 0.3M
E2E-X2D1-U 2M
E2E-X2D2-U 2M
E2E-X2D1-N 2M
E2E-X2D2-N 2M
E2E-X2D1-M1G
E2E-X2D2-M1G
E2E-X2D1-M3G
E2E-X2D2-M3G
E2E-X3D1-M1TGJ-U 0.3M
E2E-X3D2-M1TGJ-U 0.3M
E2E-X3D1-M1TGJ 0.3M
E2E-X3D1-U 2M
E2E-X3D2-U 2M
E2E-X3D1-N 2M
*1
E2E-X3D2-N 2M
E2E-X3D1-M1G
*1
E2E-X3D2-M1G
E2E-X3D1-M1GJ 0.3M
E2E-X3D2-M1GJ 0.3M
E2E-X3D1-M1J-T 0.3M
M8
2 mm
Pre-wired Models
(2 m)
---
A
D
I
H
G
M12 Pre-wired Smart-
PUR (increased
click Connector Mod-
oil-resistant)
els (0.3m)
PVC (oil-resistant)
PUR (increased
oil-resistant)
PVC (oil-resistant)
M12 Connector Mod-
els
---
Yes
No
*3
Yes
Pre-wired Models
(2 m)
M12
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NO
---
---
3 mm
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
1: +V, 2: 0 V
(3, 4): (+V, 0 V)
(1, 2): (+V, 0 V)
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
A
D
A
D
C
D
H
G
M12 Standard Pre-
wired Connector Mod- PVC (oil-resistant)
els (0.3 m)
M12 Pre-wired Smart-
PUR (increased
click Connector Mod-
oil-resistant)
els (0.3m)
PVC (oil-resistant)
PUR (increased
oil-resistant)
PVC (oil-resistant)
M12 Connector Mod-
els
---
---
E2E-X7D1-M1TGJ-U 0.3M
E2E-X7D2-M1TGJ-U 0.3M
E2E-X7D1-M1TGJ 0.3M
E2E-X7D1-U 2M
E2E-X7D2-U 2M
E2E-X7D1-N 2M
*1
E2E-X7D2-N 2M
E2E-X7D1-M1G
*1
E2E-X7D2-M1G
E2E-X7D1-M1GJ 0.3M
E2E-X7D2-M1GJ 0.3M
E2E-X7D1-M1J-T 0.3M
E2E-X7D2-M1J-T 0.3M
E2E-X10D1-M1TGJ-U 0.3M
E2E-X10D2-M1TGJ-U 0.3M
E2E-X10D1-M1TGJ 0.3M
E2E-X10D1-U 2M
E2E-X10D2-U 2M
E2E-X10D1-N 2M
*1
E2E-X10D2-N 2M
E2E-X10D1-M1G
*1
E2E-X10D2-M1G
E2E-X10D1-M1GJ 0.3M
E2E-X10D2-M1GJ 0.3M
E2E-X10D1-M1J-T 0.3M
E2E-X10D2-M1J-T 0.3M
Pre-wired Models
(2 m)
M18
Yes
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NC
NO
NO
---
---
7 mm
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
1: +V, 2: 0 V
(3, 4): (+V, 0 V)
(1, 2): (+V, 0 V)
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
A
D
A
D
C
D
H
G
M12 Standard Pre-
wired Connector Mod- PVC (oil-resistant)
els (0.3 m)
M12 Pre-wired Smart-
PUR (increased
click Connector Mod-
oil-resistant)
els (0.3m)
PVC (oil-resistant)
PUR (increased
oil-resistant)
PVC (oil-resistant)
M12 Connector Mod-
els
---
Yes
No
*3
Pre-wired Models
(2 m)
M30
Yes
NC
NO
NC
NO
NC
NO
NC
NO
NC
---
---
10 mm
1: +V, 4: 0 V
1: +V, 2: 0 V
1: +V, 4: 0 V
1: +V, 2: 0 V
(3, 4): (+V, 0 V)
(1, 2): (+V, 0 V)
A
D
A
D
C
D
M12 Standard Pre-
wired Connector Mod- PVC (oil-resistant)
els (0.3 m)
Yes
No
*3
*1. Models with different frequencies are also available. The model number is E2E-X
@D15
(example: E2E-X3D15-N 2M).
*2. Refer to page 22 for details.
*3. The residual voltage for models without polarity is 5 V, so use caution concerning the connection load interface conditions (e.g., PLC ON voltage).
The MM32 development board evaluation activity is in progress! The development boards and prizes for this activity are provided by New Drive Force Company. Thank you for the strong support of New Driv...
[size=4][color=#000000]According to the strong advice of ALTERA's official FAE (field application engineer), please be careful not to plug or unplug your JTAG download interface while it is powered on...
On-site craftsmanship is the backbone of the product manufacturing process of PCBA factories. On-site craftsmen must identify product manufacturing difficulties in advance, prevent and control various...
Author: Lucien KUANG, ST engineerClick to download the pdf document to view:Keywords: BlueNRG-1, BlueNRG-2, Mesh, low power consumptionQuestion: After getting our boards, many friends want to know whe...
0 Introduction
Direct coupling is the simplest way to connect stages. It is to directly connect the input of the latter stage with the output of the previous stage. The coupling method in which the ou...
Abstract: An automatic suspended ultrasonic probe system for CNG underground gas storage well detection and imaging is proposed. The system uses a closed-loop feedback control method to automatical...[Details]
As part of the Faraday Battery Challenge, a UK Industrial Strategy Challenge Fund, the Faraday Institution will provide four research projects with a four-year grant of £12 million per year to advanc...[Details]
introduction In recent years, with the rapid development of computer technology and integrated circuit technology, the most widely used large-screen display system is the video LED display sys...[Details]
The basic structure of the power grid dispatching automation system includes three parts: control center, master station system, plant terminal (RTU) and information channel. According to the differe...[Details]
With the increasing use of single-chip microcomputers, using them as front-end processors for data acquisition and communication is also common in various applications.
The machine collects various t...[Details]
Microsoft has previously announced a plan that the Windows 10 Mobile system will officially end on December 10, including consumer and enterprise versions. It is understood that the last release ve...[Details]
Recently, the China Automotive Power Battery Industry Innovation Alliance (hereinafter referred to as the "Battery Alliance") announced the monthly data of power batteries in April this year. The dat...[Details]
When developing a single-chip microcomputer project, keyboards are often needed, and most of the time, keyboards use single-button or matrix keyboards. Matrix keyboards have many advantages, and I ...[Details]
Oscilloscopes are widely used test instruments. They can be used to observe the waveform curves of various signal amplitudes changing over time. They can also be used to test various electrical quant...[Details]
When keil has no parameter function, like, int fun() { int i = 0; return i; } There is no problem with compilation, but in ST's CXSTM8 it needs to be written as int fun(void) { in...[Details]
Technology Frontier: The Road to Frameless Market Domination Begins
Traditionally, it is composed of a fixed stator, rotor, housing, feedback device, etc., and is mainly used in applications w...[Details]
According to foreign media reports, Vishay Intertechnology announced the launch of the new AEC-Q200 IHSR high-temperature inductor Vishay Dale IHSR-2525CZ-5A, with a case size of 7.4mm x 6.6mm x 3m...[Details]
Mouser Electronics , an electronic component distributor and Bourns have jointly launched the "Electrification of the Vehicle" e-book, which introduces new components, technologies and strategies ...[Details]
From September 7th to 8th, the 2023 World Display Industry Conference was grandly opened in Chengdu. BOE (BOE) participated in this industry event in a new role and hosted the "Define the Future Smar...[Details]
Power loss model generation tool now includes passive components, enabling more accurate design modeling and helping customers get to market faster
Shanghai, China, November 14, 20...[Details]