APPLICATION SPECIFICATION
Mini-fit TPA2
INTERCONNECT SYSTEMS
Plug
w/ TPA
Receptacle
w/ TPA
See section 2.1 for series numbers
Male Crimp
Female Crimp
Terminal
Terminal
TPA Retainer
Plug
Housing
CPA
TPA
Retainer
TPA Retainer
Plug
Housing,
Panel
Mount
Receptacle
Housing
REVISION:
ECR/ECN INFORMATION:
EC No:
DATE:
TITLE:
A3
603152
2018/20/08
APPLICATION SPECIFICATION FOR
MINI-FIT TPA2
CONNECTOR SYSTEM
CHECKED BY:
SHEET No.
1
of
12
DOCUMENT NUMBER:
CREATED / REVISED BY:
APPROVED BY:
AS-172718-0000
sgangadhardo
mramakrishna
ishwarg
TEMPLATE FILENAME: APPLICATION_SPEC[SIZE_A](V.1).DOC
APPLICATION SPECIFICATION
1.0 SCOPE
This Application Specification covers the performance requirements for the MINI-FIT TPA2 Wire-
To-Board and Wire-To-Wire, 4.20mm pitch dual row and single row connector series using brass,
phos bronze and high conductive copper alloy terminals with Tin and Gold plating terminated with 16
to 24 AWG wire using Molex crimp technology. The TPA Retainer (terminal position assurance) is
intended to ensure the crimp terminals are fully seated and to prevent incidence of terminal back-out
due to partially seated terminals. The connector position assurance (CPA) latch optional, will prevent
connector accidental un-mating. This document is NOT intended to be the final process definition nor
is it intended to constrain design.
2.0 PRODUCT DESCRIPTION
2.1 NAMES AND SERIES NUMBER(S)
WIRE-TO-BOARD
Description
Mini-Fit TPA2, Receptacle Hsg, Dual Row
Mini-Fit TPA2, Receptacle Hsg, Single Row
Mini-Fit TPA2, Female Crimp Terminal
Mini-Fit TPA2, TPA Retainer
Mini-Fit TPA2, CPA
Series
Number
172708
200453
172718
172709
203603
UL
(600 V)
Yes
Yes
Yes
Yes
Yes
CSA
(250 V)
Yes
Yes
Yes
Yes
Yes
IEC
(250 V)
Yes
Yes
Yes
Yes
Yes
WIRE-TO-WIRE
Description
Mini-Fit TPA2, Female Crimp Terminal
Mini-Fit TPA2, Receptacle Hsg, Dual Row
Mini-Fit TPA2, Receptacle Hsg, Single Row
Mini-Fit TPA2, TPA Retainer
Mini-Fit TPA2, CPA
Mini-Fit TPA2, Male Crimp Terminal
Mini-Fit TPA2, Plug Hsg, Dual Row
Mini-Fit TPA2, Plug Hsg, Panel Mount, Dual Row
Mini-Fit TPA2, Plug Hsg, Single Row
Mini-Fit TPA2, Plug Hsg, Panel Mount, Single Row
Series
Number
172718
202988
172708
200453
172709
203603
172765
203070
172762
172767
200471
200488
UL
(600 V)
Yes
TBE
Yes
Yes
Yes
Yes
Yes
TBE
Yes
Yes
Yes
Yes
CSA
(250 V)
Yes
TBE
Yes
Yes
Yes
Yes
Yes
TBE
Yes
Yes
Yes
Yes
IEC
(250 V)
Yes
TBE
Yes
Yes
Yes
Yes
Yes
TBE
Yes
Yes
Yes
Yes
2.2 DIMENSIONS, MATERIALS, PLATINGS AND MARKINGS
See the appropriate sales drawings for the information on dimensions, materials, platings and
markings.
REVISION:
ECR/ECN INFORMATION:
EC No:
DATE:
TITLE:
A3
603152
2018/20/08
APPLICATION SPECIFICATION FOR
MINI-FIT TPA2
CONNECTOR SYSTEM
CHECKED BY:
SHEET No.
2
of
12
DOCUMENT NUMBER:
CREATED / REVISED BY:
APPROVED BY:
AS-172718-0000
sgangadhardo
mramakrishna
ishwarg
TEMPLATE FILENAME: APPLICATION_SPEC[SIZE_A](V.1).DOC
APPLICATION SPECIFICATION
3.0 APPLICABLE DOCUMENTS AND SPECIFICATIONS
Product Specification
Receptacle Crimp Terminal Sales Drawing
Receptacle Dual Row Housing Sales Drawing
Receptacle Single Row Housing Sales Drawing
TPA Sales Drawing
CPA Sales Drawing
Plug Crimp Terminal Sales Drawing
Plug Dual Row Housing Sales Drawing
Plug Single Row Housing Sales Drawing
Plug Dual Row Housing, Panel Mount Sales Drawing
Plug Single Row Housing, Panel Mount Sales Drawing
Technical Advisory Moistrurizing Nylon Connector Parts
4.0 GENERAL APPLICATION NOTES
Appearance:
Parts conform to class "B" requirements of cosmetic specification PS-45499-002 except where
noted on the sales drawings.
Connector Application
This connector system is designed to mate gold plating to gold plating OR tin plating to tin plating.
Never cross mate tin plated parts to gold plated parts.
Connectors are not to be mated or unmated while circuits are live except per the current interrupt
rating listed in product specification: PS-172718-0000 and 2029880001-PS.
Packaging
Parts shall be packaged to protect against damage during handling, transit and storage. Nylon
parts should remain in their original packaging until ready for use. Refer to Molex specification
AS-45499-001 for moisturizing nylon connector parts.
PS-172718-0000/2029880001-PS
SD-172718-0000/2029880001 PSD
SD-172708-0000
2004530000-SD
SD-172709-0000/1727090001-SD
2036030000-SD
SD-172765-0000/2030700001 PSD
SD-172762-0000
2004710000-SD
SD-172767-0000
2004880000-SD
AS-45499-001
REVISION:
ECR/ECN INFORMATION:
EC No:
DATE:
TITLE:
A3
603152
2018/20/08
APPLICATION SPECIFICATION FOR
MINI-FIT TPA2
CONNECTOR SYSTEM
CHECKED BY:
SHEET No.
3
of
12
DOCUMENT NUMBER:
CREATED / REVISED BY:
APPROVED BY:
AS-172718-0000
sgangadhardo
mramakrishna
ishwarg
TEMPLATE FILENAME: APPLICATION_SPEC[SIZE_A](V.1).DOC
APPLICATION SPECIFICATION
5.0 CRIMPED TERMINAL EXTRACTION
Male and Female terminal extraction tool: See Molex part# 63824-6210 instructions online on
website. Do not reuse terminals that have been removed with the extraction tool. The housings
can be reused if it was not damaged.
6.0 TIE AND OR WIRE TWIST LOCATION
CKT Size
2-6
8
10-12
14-16
18-20
22-24
Dim T Min.
.50” (12.7 mm)
.75” (19.1 mm)
1.00” (25.4 mm)
1.34” (34.0 mm)
1.45” (37.0 mm)
1.57” (40.0 mm)
Note: Pictorial view shown for illustration purpose.
The “T” dimension defines a “free” length of wire, or a length of wire that is not subject to
significant bias by external factors such as a wire tie, wire twisting, or other means of
bending or deforming of the wires that repositions them from their natural relaxed state
or location where they enter the housing. This dimension is a general recommendation
and may need to be adjusted for different wire gauges and wire type and insulation
thickness and insulation material.
Wires are to be dressed in such a manner to allow the terminals to float freely in the housing
pocket.
7.0 CONNECTOR TESTING
Refer the PS-177718-0000 and 2029880001-PS for information on testing.
REVISION:
ECR/ECN INFORMATION:
EC No:
DATE:
TITLE:
A3
603152
2018/20/08
APPLICATION SPECIFICATION FOR
MINI-FIT TPA2
CONNECTOR SYSTEM
CHECKED BY:
SHEET No.
4
of
12
DOCUMENT NUMBER:
CREATED / REVISED BY:
APPROVED BY:
AS-172718-0000
sgangadhardo
mramakrishna
ishwarg
TEMPLATE FILENAME: APPLICATION_SPEC[SIZE_A](V.1).DOC
APPLICATION SPECIFICATION
8.0 TERMINALS AND HOUSINGS
172718/202988 series terminals should only be used with Receptacle housing series’ 172708
(Dual row) and 200453 (Single Row).
172765/203070 series terminals should only be used with Plug housing series’ 172767 & 172762
(Dual row) and 200471 & 200488 (Single Row).
9.0 TERMINAL INSERTION INTO HOUSING
Terminals are to be inserted in the housing as shown below in Figure 1. Notice the orientation of
the stop tabs. Do not force terminals into the housing cavity. The terminal and housing are
designed with features that provide some light resistance during insertion as well as retention
after insertion but if excessive resistance is felt during insertion pull terminal back out and
double check that the terminal orientation is per Figure 1. Terminals are to be inserted until they
are fully seated as shown in Figure 2 and cannot fall out or be pulled out easily. The terminal
stop tabs provide a stopping surface and the locking tangs provide a light audible click to
indicate a fully inserted terminal.
Series 172718/202988
only Stop Tap Up
Series 172718/202988
only Stop Tap Down
Figure 1
Series 172708 only
Stop Tap Up
Fully Seated
Fully Seated
REVISION:
ECR/ECN INFORMATION:
EC No:
DATE:
TITLE:
Figure 2
A3
603152
2018/20/08
APPLICATION SPECIFICATION FOR
MINI-FIT TPA2
CONNECTOR SYSTEM
CHECKED BY:
SHEET No.
5
of
12
DOCUMENT NUMBER:
CREATED / REVISED BY:
APPROVED BY:
AS-172718-0000
sgangadhardo
mramakrishna
ishwarg
TEMPLATE FILENAME: APPLICATION_SPEC[SIZE_A](V.1).DOC