EEWORLDEEWORLDEEWORLD

Part Number

Search

1552400200

Description
CABLE 11X1.5 PLTC GY UNSH G/Y D1
CategoryWire/cable   
File Size1MB,9 Pages
ManufacturerMolex Premise Network
Download Datasheet Parametric View All

1552400200 Overview

CABLE 11X1.5 PLTC GY UNSH G/Y D1

1552400200 Parametric

Parameter NameAttribute value
Cable typemulti-core
Number of conductors11
Wire gauge16 AWG
Number of wire strands81/0.0059"
conductor materialbare copper
Sheath (insulation) materialThermoplastic (TPE)
Sheath (insulation) diameter0.559"(14.20mm)
Shield type-
length1640.4'(500.0m)
Casing colorgrey
grade-
characteristic-
Voltage300V
Operating temperature-40°C ~ 105°C
useindustry, signal, control
Sheath (insulation) thickness0.0236"(0.600mm)
conductor insulationPolyvinyl chloride (PVC)
shielding material-
Shielding range-
PRODUCT SPECIFICATION
CABLE SERIES 155240 (Unshielded) – 155241 (Shielded)
Signal & Control - UL Listed - TPE jacket
PLTC or CMG (105°C) or
AWM (105°C/300V)
1. CONSTRUCTION DATA
1.1
CONDUCTOR:
Bare copper strand; according to EN 13602 - ETP1; stranding according to DIN VDE 0295, EN60228 Class 6
Stranded lay compliant with UL 13/UL444/UL758.
Certificato N. 9125.FLA2
ISO 9001
1.2
WIRE STRUCTURE:
Nominal
Section
(mm²)
AWG
22
21
19
18
16
14
Stranding
(nbr of wires x wire
diameter in mm)
Diameter of
stranded core
(mm)
Max Resistance
IEC60334 (Ω/km)
0.34
0.50
0.75
1.00
1.50
2.50
1.3
1.4
INSULATION:
42x0.10
28x0.15
42x0.15
52x0.15
81x0.15
133x0.15
0.80
0.95
1.20
1.32
1.50
2.10
65.3
42.3
27.7
22.4
14.4
8.7
PVC compound; Max Insulation resistance 30.5 MΩxKm @15.6°C, nominal hardness 48 Shore D
INSULATION DIAMETER
Section
(mm²)
Nominal Ø
(mm)
Nominal thickness
(mm)
0.34
0.50
0.75
1.00
1.50
2.50
1.5
ASSEMBLY:
1.35
1.65
2.10
2.45
2.70
3.60
0.27
0.35
0.45
0.55
0.60
0.75
Cores stranded together in one or two layers (depending on the number of cores), where if necessary one or more fillers
can be used for a better roundness.
1.6
SHIELD (only for 0.34mm², series 155241):
Braid type, tin copper wire; nominal optical Coverage 80%; tapes are used for protection of shield, PET foil under braid
and Nonwovens TNT over braid.
1.7
JACKET:
Thermoplastic compound (TPE), nominal hardness 78 Shore A; Silicone, Pb,Cd,Hg & FCKW free; according to UL758.
For overall diameter, jacket and cores colors refer to Annex #1 & #2
REVISION HISTORY
Rev.A 04/11/2015 RELEASED
Document Number:
ECR/ECN INFORMATION:
TITLE:
Page
SIGNAL & CONTROL – UL Listed
Created/Revised by:
M. Arrigoni
Checked by:
A. Defendi
Approved by:
C. Lerose
1
of
9
1552400001 PS P1E A
THIS DOCUMENT CONTAINS INFORMATION THAT IS PROPRIETARY TO MOLEX ELECTRONIC TECHNOLOGIES, LLC AND SHOULD NOT BE USED WITHOUT WRITTEN PERMISSION
Template: TDS REV.0 22/07/2015

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号