P
OLYFUSE
®
R
ESETTABLE
F
USES
VTD
Strap Type, 16 V
Standard
UL 1434 1
st
Edition
CSA C22.2 No. 0 CSA TIL No. CA-3A
cULus Recognition
TÜV
The new VTD product series feature a slim, low
profile and low resistance design. These devices
are ideal to be installed directly onto the latest
generation batteries including cylindrical and
prismatic cells. The VTD product offers protec-
tion against both overcurrent and overtempera-
ture fault conditions.
Specifications
Packaging
A
small pack
D
standard
Materials
Insulating material: Polyester Tape
Terminals:
Nickel
Max. Device Surface Temperature in Tripped State
110 °C
Operating / Storage Temperature
-40 ºC to +85 ºC (consider derating)
Humidity Ageing
+60 °C, 95 % R.H., 1000 hours, ± 10 % typical
resistance change
Vibration
MIL-STD-883C, Condition A, no change
Thermal Shock
MIL-STD-202F, Method 107G
+85 °C to -40 °C 10 times ±5 % typical resistance
change
Marking
“P”, Part Code, identification, lot number
Approvals
Features
Dimensions (mm)
S: one slot
SS: two slots
Dimensions (mm)
Model
VTD170
VTD170XS
VTD175
VTD175S
VTD175L
VTD175XL
VTD200
VTD200S
VTD210
VTD210S
VTD210SS
VTD210L
VTD210LS
VTD240
Fig
1
2
1
2
1
4
1
2
1
2
3
1
2
1
A
Min Max
15.4
20.9
20.9
20.9
26.0
25.5
20.9
20.9
20.9
20.9
20.9
24.0
24.0
24.2
17.5
22.9
22.2
22.2
28.0
28.2
23.1
23.1
23.1
23.1
23.1
26.0
26.0
26.2
B
Min Max
7.0
4.9
3.5
3.5
3.5
3.5
3.8
3.8
4.9
4.9
4.9
4.9
4.9
4.9
7.4
5.3
3.8
3.8
3.8
3.9
4.3
4.3
5.3
5.3
5.3
5.3
5.3
5.3
C
Min Max
0.5
0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.8
0.8
0.7
0.7
0.8
0.8
0.7
0.7
0.8
0.8
0.8
0.8
0.8
0.8
D
Min
4.0
4.0
4.0
4.0
6.5
8.7
4.0
4.0
4.1
4.1
4.1
5.0
5.0
5.0
E
F
Min Max Min
3.9
3.9
2.9
2.9
2.9
2.4
2.9
2.9
3.9
3.9
3.9
3.9
3.9
3.9
4.1
4.1
3.1
3.1
3.1
2.6
3.1
3.1
4.1
4.1
4.1
4.1
4.1
4.1
packaging quantity
small pack standard
500
500
500
500
500
500
500
500
500
500
500
500
500
500
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
5.7
Permissible continuous operating current is
≤
100 % at ambient temperature of 20 ºC (68 ºF).
Model
cURus
•
•
•
•
•
•
•
•
•
•
•
•
•
•
VTD170
VTD170XS
VTD175
VTD175S
VTD175L
VTD175XL
VTD200
VTD200
VTD210
VTD210S
VTD210SS
VTD210L
VTD210LS
VTD240
NOTE:
I
hold
=
I
trip
=
V
max
=
I
max
=
1.70
1.70
1.75
1.75
1.75
1.75
2.00
2.00
2.10
2.10
2.10
2.10
2.10
2.40
3.40
3.40
3.80
3.80
3.80
3.80
4.50
4.50
4.70
4.70
4.70
4.70
4.70
5.40
15
15
15
15
15
15
15
15
15
15
15
15
15
15
100
100
100
100
100
100
100
100
100
100
100
100
100
100
3.0 @ 8.5
3.0 @ 8.5
3.0 @ 8.5
3.0 @ 9.0
3.0 @ 9.0
5.0 @ 8.75
4.0 @ 10.0
4.0 @ 10.0
5.0 @ 10.0
5.0 @ 10.0
5.0 @ 10.0
5.0 @ 10.0
5.0 @ 10.0
4.0 @ 12.0
1.40
1.40
1.40
1.40
1.40
1.40
1.50
1.50
1.50
1.50
1.50
1.50
1.50
1.50
0.030
0.030
0.025
0.025
0.025
0.029
0.021
0.021
0.018
0.018
0.018
0.018
0.018
0.015
0.052
0.052
0.045
0.045
0.045
0.051
0.039
0.039
0.030
0.030
0.030
0.030
0.030
0.026
0.105
0.105
0.045
0.090
0.090
0.102
0.080
0.080
0.060
0.060
0.060
0.060
0.060
0.052
Hold current: maximum current device will pass without tripping in 20 °C still air.
Trip current: minimum current at which the device will trip in 20 °C still air.
Maximum voltage device can withstand without damage at rated current (I
max
)
Maximum fault current device can withstand without damage at rated voltage (V
max
)
P
d
=
Power dissipated from device when in the tripped state at 20 °C still air.
Minimum resistance of device in initial (un-soldered) state.
R
min
=
Maximum resistance of device at 20 °C measured one hour after tripping for 20 s.
R
1max
=
Caution: Operation beyond the specified rating may result in damage and possible arcing and
fl
ame.
Specifications are subject to change without notice
Order
Information
Qty.
Order-
Number
Model
Packaging
041006
In our continuing strategy to deliver unparalleled circuit protection solutions,
technical expertise and application leadership, we proudly introduce the
WICKMANN Group and its products to the Littelfuse portfolio.
www.littelfuse.com
TÜV
•
•
•
•
•
•
•
•
•
•
•
•
•
•
I
hold
(A)
I
Trip
(A)
V
max. dc
(V)
I
max.
(A)
max. time to trip
(s @ A)
P
d max.
(W)
Resistance
Approvals
R
min.
( ) R
max.
( ) R
I max.
( )
P
OLYFUSE
®
R
ESETTABLE
F
USES
VTD
AB
100.00
A: VTD170
B: VTD210
10.00
Time-to-Trip (s)
1.00
0.10
0.01
1.00
10.00
100.00
Fault Current (A)
Further Time-Current-Curves on request
Thermal Derating Chart
Model
Ambient Operation Temperature - I
hold
(A)
-40 °C
VTD170
VTD170XS
VTD175
VTD175S
VTD175L
VTD175XL
VTD200
VTD200S
VTD210
VTD210S
VTD210SS
VTD210L
VTD210LS
VTD240
3.20
3.20
3.20
3.20
3.20
3.20
3.70
3.70
4.10
4.10
4.10
4.10
4.10
4.40
-20 °C
2.70
2.70
2.70
2.70
2.70
2.70
3.20
3.20
3.50
3.50
3.50
3.50
3.50
3.70
0 °C
2.20
2.20
2.20
2.20
2.20
2.20
2.60
2.60
2.90
2.90
2.90
2.90
2.90
3.10
23 °C
1.70
1.70
1.75
1.75
1.75
1.75
2.00
2.00
2.10
2.10
2.10
2.10
2.10
2.40
40 °C
1.30
1.30
1.30
1.30
1.30
1.30
1.50
1.50
1.60
1.60
1.60
1.60
1.60
1.80
50 °C
1.00
1.00
1.00
1.00
1.00
1.00
1.20
1.20
1.30
1.30
1.30
1.30
1.30
1.50
60 °C
0.80
0.80
0.80
0.80
0.80
0.80
0.90
0.90
1.00
1.00
1.00
1.00
1.00
1.20
70 °C
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.70
0.70
0.70
0.70
0.70
0.90
85 °C
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.10
041006
In our continuing strategy to deliver unparalleled circuit protection solutions,
technical expertise and application leadership, we proudly introduce the
WICKMANN Group and its products to the Littelfuse portfolio.
www.littelfuse.com