DC-DC Converters PCB Mount Type
Ordering information
MGW1R5
MG
1
2
W
1R5
3
4
24
5
12
6
-O
R
1
Series name
2
Dual output
3
Output wattage
4
Input voltage
5
Output voltage
6
Optional
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
VOLTAGE[V]
CURRENT[A]
*1
MGW1R50512 MGW1R50515 MGW1R51212 MGW1R51215 MGW1R52412 MGW1R52415 MGW1R54812 MGW1R54815
1.56
±12 or +24
0.065
1.50
±15 or +30
0.05
1.56
±12 or +24
0.065
1.50
±15 or +30
0.05
1.56
±12 or +24
0.065
1.50
±15 or +30
0.05
1.56
±12 or +24
0.065
1.50
±15 or +30
0.05
SPECIFICATIONS
MODEL
VOLTAGE[V]
INPUT
CURRENT[A]
EFFICIENCY[%]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
*3
*4
*5
*5
*2
*2
MGW1R50512 MGW1R50515 MGW1R51212 MGW1R51215 MGW1R52412 MGW1R52415 MGW1R54812 MGW1R54815
DC4.5 - 9
DC9 - 18
(Surge voltage 12.5V, 100ms max) (Surge voltage 25V, 100ms max)
0.38typ
83typ
±12 or +24
0.065
60max
480max
600max
150max
200max
0.38typ
81typ
±15 or +30
0.05
75max
600max
750max
150max
200max
260max
390max
60max
0.16typ
83typ
±12 or +24
0.065
60max
480max
600max
150max
200max
210max
320max
48max
0.16typ
81typ
±15 or +30
0.05
75max
600max
750max
150max
200max
260max
390max
60max
DC18 - 36
(Surge voltage 50V, 100ms max)
0.080typ
82typ
±12 or +24
0.065
60max
480max
600max
150max
200max
210max
320max
48max
0.079typ
80typ
±15 or +30
0.05
75max
600max
750max
150max
200max
260max
390max
60max
DC36 - 76
(Surge voltage 100V, 100ms max)
0.041typ
81typ
±12 or +24
0.065
60max
480max
600max
150max
200max
210max
320max
48max
0.040typ
80typ
±15 or +30
0.05
75max
600max
750max
150max
200max
260max
390max
60max
OUTPUT
RIPPLE[mVp-p]
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
DRIFT[mV]
START-UP TIME[ms]
-20 to +85C
210max
-40 to +85C
320max
*6
48max
30max (Minimum input, Io=100%)
11.64 - 12.36 14.55 - 15.45 11.64 - 12.36 14.55 - 15.45 11.64 - 12.36 14.55 - 15.45 11.64 - 12.36 14.55 - 15.45
DC1,500V or AC1,000V 1minute, Cutoff current=10mA, DC500V 1,000MW min (20±15C)
-40 to +100C, 20 to 95%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz 98.0m/s
2
(10G), 3minute period, 60minutes each along X, Y and Z axis
490.3m/s
2
(50G) 11ms, once each along X, Y and Z axis
UL60950-1, C-UL, EN60950-1
17.0X12.0X8.5mm [0.67X0.48X0.34 inches] (WXHXD) / 4g max
Convection/Forced air
OUTPUT VOLTAGE SETTING[V]
PROTECTION CIRCUIT OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
ISOLATION
INPUT-OUTPUT
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
SAFETY
OTHERS
*1
*2
*3
*4
*5
*6
*
OPERATING TEMP.,HUMID.AND ALTITUDE
-40 to +85C, 20 to 95%RH (Non condensing) (Required derating), 5,000m (16,400feet) max
ENVIRONMENT
AGENCY APPROVALS
CASE SIZE/WEIGHT
COOLING METHOD
Single output +24V, +30V with no use of COM.
Rated input 5V, 12V, 24V or 48V DC Io=100%
Symmetrical loading from 20% to 100%.
Symmetrical loading from 0% to 100%.
Ripple and Ripple Noise is measured by using test board with ceramic capacitor 1 F at
50mm from output pins. (20MHz Osilloscope)
Drift is the DC output accuracy for eight hours period after a half-hour warm-up at 25C.
Parallel operation with other model is not possible.
MG-14
MGW1R5
External view
Model
¶
Recommended Pad and Hole dia.
(TOP
VIEW)
5-f0.9
Model
3.5
[0.14]
0.5
[0.02]
12
[0.48]
2.54
[0.1]
12.7
[0.5]
2.2
[0.09]
2.8
[0.11]
¶
Unit : 0.1inch
¶
Dimension : mm
¶
Tolerance
±0.5
[±0.02]
¶
Dimensions in mm, [ ]= inches
¶
Pin terminal material : Copper
¶
Planting treatment of terminal : Lead free plating
¶
Case material : PBT
¶
Weight 4g max
-
Vin
+
Vin
+
Vout COM
-
Vout
17
[0.67]
0.5
[0.02]
0.25
[0.01]
8.5
[0.34]
MG-15
DC-DC Converters PCB Mount Type
Ordering information
MGW3
MG
1
2
W
3
3
4
24
5
12
6
-O
R
1
Series name
2
Dual output
3
Output wattage
4
Input voltage
5
Output voltage
6
Optional
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
VOLTAGE[V]
CURRENT[A]
*1
MGW30512
3.12
±12 or +24
0.13
MGW30515
3.00
±15 or +30
0.1
MGW31212
3.12
±12 or +24
0.13
MGW31215
3.00
±15 or +30
0.1
MGW32412
3.12
±12 or +24
0.13
MGW32415
3.00
±15 or +30
0.1
MGW34812
3.12
±12 or +24
0.13
MGW34815
3.00
±15 or +30
0.1
SPECIFICATIONS
MODEL
VOLTAGE[V]
INPUT
CURRENT[A]
EFFICIENCY[%]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
*3
*4
*5
*5
*2
*2
MGW30512
MGW30515
MGW31212
MGW31215
MGW32412
MGW32415
MGW34812
MGW34815
DC4.5 - 9
DC9 - 18
(Surge voltage 12.5V, 100ms max) (Surge voltage 25V, 100ms max)
0.76typ
83typ
±12 or +24
0.13
60max
480max
600max
150max
200max
0.74typ
82typ
±15 or +30
0.1
75max
600max
750max
150max
200max
220max
340max
60max
0.31typ
84typ
±12 or +24
0.13
60max
480max
600max
150max
200max
180max
290max
48max
0.31typ
83typ
±15 or +30
0.1
75max
600max
750max
150max
200max
220max
340max
60max
DC18 - 36
(Surge voltage 50V, 100ms max)
0.16typ
83typ
±12 or +24
0.13
60max
480max
600max
150max
200max
180max
290max
48max
0.16typ
83typ
±15 or +30
0.1
75max
600max
750max
150max
200max
220max
340max
60max
DC36 - 76
(Surge voltage 100V, 100ms max)
0.080typ
82typ
±12 or +24
0.13
60max
480max
600max
150max
200max
180max
290max
48max
0.077typ
82typ
±15 or +30
0.1
75max
600max
750max
150max
200max
220max
340max
60max
OUTPUT
RIPPLE[mVp-p]
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
DRIFT[mV]
START-UP TIME[ms]
-20 to +70C
180max
-40 to +70C
290max
*6
48max
30max (Minimum input, Io=100%)
11.64 - 12.36 14.55 - 15.45 11.64 - 12.36 14.55 - 15.45 11.64 - 12.36 14.55 - 15.45 11.64 - 12.36 14.55 - 15.45
DC1,500V or AC1,000V 1minute, Cutoff current=10mA, DC500V 1,000MW min (20±15C)
-40 to +100C, 20 to 95%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz 98.0m/s
2
(10G), 3minute period, 60minutes each along X, Y and Z axis
490.3m/s
2
(50G) 11ms, once each along X, Y and Z axis
UL60950-1, C-UL, EN60950-1
17.0X12.0X8.5mm [0.67X0.48X0.34 inches] (WXHXD) / 4g max
Convection/Forced air
OUTPUT VOLTAGE SETTING[V]
PROTECTION CIRCUIT OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
ISOLATION
INPUT-OUTPUT
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
SAFETY
OTHERS
*1
*2
*3
*4
*5
*6
*
OPERATING TEMP.,HUMID.AND ALTITUDE
-40 to +85C, 20 to 95%RH (Non condensing) (Required derating), 5,000m (16,400feet) max
ENVIRONMENT
AGENCY APPROVALS
CASE SIZE/WEIGHT
COOLING METHOD
Single output +24V, +30V with no use of COM.
Rated input 5V, 12V, 24V or 48V DC Io=100%
Symmetrical loading from 20% to 100%.
Symmetrical loading from 0% to 100%.
Ripple and Ripple Noise is measured by using test board with ceramic capacitor 1 F at
50mm from output pins. (20MHz Osilloscope)
Drift is the DC output accuracy for eight hours period after a half-hour warm-up at 25C.
Parallel operation with other model is not possible.
MG-16
MGW3
External view
Model
¶
Recommended Pad and Hole dia.
(TOP
VIEW)
5-f0.9
Model
3.5
[0.14]
0.5
[0.02]
12
[0.48]
2.54
[0.1]
12.7
[0.5]
2.2
[0.09]
2.8
[0.11]
¶
Unit : 0.1inch
¶
Dimension : mm
¶
Tolerance
±0.5
[±0.02]
¶
Dimensions in mm, [ ]= inches
¶
Pin terminal material : Copper
¶
Planting treatment of terminal : Lead free plating
¶
Case material : PBT
¶
Weight 4g max
-
Vin
+
Vin
+
Vout COM
-
Vout
17
[0.67]
0.5
[0.02]
0.25
[0.01]
8.5
[0.34]
MG-17
DC-DC Converters PCB Mount Type
Ordering information
MGW6
MG
1
2
W
3
6
4
24
5
12
6
-O
R
1
Series name
2
Dual output
3
Output wattage
4
Input voltage
5
Output voltage
6
Optional
Y2 : Output voltage
adjustable (+10%, -5%)
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
VOLTAGE[V]
CURRENT[A]
*1
MGW60512
6.00
±12 or +24
0.25
MGW60515
6.00
±15 or +30
0.2
MGW61212
6.00
±12 or +24
0.25
MGW61215
6.00
±15 or +30
0.2
MGW62412
6.00
±12 or +24
0.25
MGW62415
6.00
±15 or +30
0.2
MGW64812
6.00
±12 or +24
0.25
MGW64815
6.00
±15 or +30
0.2
SPECIFICATIONS
MODEL
VOLTAGE[V]
INPUT
CURRENT[A]
EFFICIENCY[%]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV]
RIPPLE[mVp-p]
*3
*4
*2
*2
MGW60512
MGW60515
MGW61212
MGW61215
MGW62412
MGW62415
MGW64812
MGW64815
DC4.5 - 9
DC9 - 18
(Surge voltage 12.5V, 100ms max) (Surge voltage 25V, 100ms max)
1.38typ
87typ
±12 or +24
0.25
60max
480max
600max
1.38typ
87typ
±15 or +30
0.2
75max
600max
750max
120max
480max
200max
600max
220max
340max
60max
0.57typ
88typ
±12 or +24
0.25
60max
480max
600max
120max
360max
200max
500max
180max
290max
48max
0.57typ
88typ
±15 or +30
0.2
75max
600max
750max
120max
360max
200max
500max
220max
340max
60max
DC18 - 36
(Surge voltage 50V, 100ms max)
0.29typ
88typ
±12 or +24
0.25
60max
480max
600max
120max
360max
200max
500max
180max
290max
48max
0.29typ
88typ
±15 or +30
0.2
75max
600max
750max
120max
360max
200max
500max
220max
340max
60max
DC36 - 76
(Surge voltage 100V, 100ms max)
0.15typ
88typ
±12 or +24
0.25
60max
480max
600max
120max
360max
200max
500max
180max
290max
48max
0.15typ
88typ
±15 or +30
0.2
75max
600max
750max
120max
360max
200max
500max
220max
340max
60max
Po=30% to
120max
*5
OUTPUT
Po=0 to 30%
480max
Po=30% to
200max
Po=0 to 30%
600max
-20 to +70C
180max
-40 to +70C
290max
*6
RIPPLE NOISE[mVp-p]
*5
TEMPERATURE
REGULATION[mV]
DRIFT[mV]
START-UP TIME[ms]
48max
30max (Minimum input, Io=100%)
11.64 - 12.36 14.55 - 15.45 11.64 - 12.36 14.55 - 15.45 11.64 - 12.36 14.55 - 15.45 11.64 - 12.36 14.55 - 15.45
Works over 105% of rating and recovers automatically
Provided (Negative logic L : ON, H : OFF)
DC1,500V or AC1,000V 1minute, Cutoff current=10mA, DC500V 1,000MW min (20±15C)
-40 to +100C, 20 to 95%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz 98.0m/s
2
(10G), 3minute period, 60minutes each along X, Y and Z axis
490.3m/s
2
(50G) 11ms, once each along X, Y and Z axis
UL60950-1, C-UL, EN60950-1
22.0X12.0X9.5mm [0.87X0.48X0.38 inches] (WXHXD) / 7g max
Convection/Forced air
OUTPUT VOLTAGE SETTING[V]
PROTECTION
OVERCURRENT PROTECTION
CIRCUIT AND
REMOTE ON/OFF
OTHERS
ISOLATION
INPUT-OUTPUT
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CASE SIZE/WEIGHT
COOLING METHOD
OPERATING TEMP.,HUMID.AND ALTITUDE
-40 to +85C, 20 to 95%RH (Non condensing) (Required derating), 5,000m (16,400feet) max
ENVIRONMENT
SAFETY
OTHERS
*1
*2
*3
*4
*5
*6
*
Single output +24V, +30V with no use of COM.
Rated input 5V, 12V, 24V or 48V DC Io=100%
Symmetrical loading from 20% to 100%.
Symmetrical loading from 0% to 100%.
Ripple and Ripple Noise is measured by using test board with ceramic capacitor 1 F at
50mm from output pins. (20MHz Osilloscope). Po:Output wattage.
Drift is the DC output accuracy for eight hours period after a half-hour warm-up at 25C.
Parallel operation with other model is not possible.
MG-18