ODU MINI-SNAP® Series F
Assembly Instructions
010.054.000.000.000
Unsealed Plugs (IP 50)
– Crimp Version
– Solder Version
Sealed Plugs (IP 68)
– Crimp Version
– Solder Version
Sealed Right-Angled Plugs (IP 68)
– Crimp Version
– Solder Version
www.odu.de
ODU MINI-SNAP® Series F
Assembly Straight Plug and In-line Receptacle IP 50
Crimp Version
010.054.000.000.000
Assembly Instructions
Back nut (style 1)
Insert with
solder capacity
In-line receptacle
Half-shells
EMI ring Cable collet
Plug
Crimp insert
Back nut for
cable bend relief
(style 2)
cable bend
relief
1. Slide cable bend relief, back nut, cable collet and EMI ring over the cable.
2. Strip cable and wire
corresponding the table
(see page 18).
3. Fit wire into the contact barrel
and crimp.
Page 2
www.odu.de
ODU MINI-SNAP® Series F
010.054.000.000.000
Assembly Instructions
4. Insert contacts into insulator
according to contact arrangement.
5. Bend cable shield outwards.
Assemble half-shells.
6. Slide the EMI ring and the cable
collet against the half-shells and
clamp the shield against it.
7. Put the assembled cable
considering the guidings (B) in the
connector housing. If necessary,
secure thread (A) with adhesive
(see page 18) .
A
B
8. Screw back nut on the assembled
plug and hold against (C) with
ODU spanner wrench.
Caution! Consider tightening
torque (see page 18). The
assembly is finished.
C
www.odu.de
Page 3
ODU MINI-SNAP® Series F
Assembly Straight Plug and In-line Receptacle IP 50
Solder Version
010.054.000.000.000
Assembly Instructions
Back nut (style 1)
Insert with
solder capacity
In-line receptacle
Half-shells
EMI ring
Cable collet
Plug
Crimp insert
Back nut for
cable bend relief
(style 2)
cable bend
relief
1. Slide cable bend relief, back nut, cable collet and EMI ring over the cable.
2. Strip cable and wire
corresponding the table
(see page 18).
3. Pre-tinning of strands.
Page 4
www.odu.de
ODU MINI-SNAP® Series F
010.054.000.000.000
Assembly Instructions
4. Solder the wires (A) according to
contact arrangement.
A
5. Bend cable shield outwards,
assemble half shells.
6. Slide the EMI ring and the cable
collet against the half-shells and
clamp the shield against it.
7. Put the assembled cable
considering the guidings (C) in the
connector housing. If necessary,
secure thread (B) with adhesive
(see page 18).
B
C
8. Screw back nut on the assembled
plug, counterhold by means of the
spanner flat (D) and hold against
with ODU spanner wrench.
Caution! Consider tightening
torque (see page 18).
The assembly is finished.
D
www.odu.de
Page 5