Power entry modules without line filter
https://www.schurter.com /PG05
CMF1, CMF4
IEC Appliance Inlet C8 with Line Switch 1-pole
CMF1
C8
Approvals and Compliances
70° C
See below:
Description
- Panel mount :
Screw-on mounting on PCB , from top or bottom
- 2 Functions :
Appliance Inlet Protection class II , Line Switch 1-pole
- For PCB mounting
Characteristics
- Easy mounting with center bolt and snapper or srewed on PCB or
housing
- Electrical connection done on the PCB
- Bi-positioning of the switch from left or right side, Standard CMF with
switch on right side
- With or without rear-side insulation cover
- Suitable for use in equipment according to IEC/UL 60950
Other versions on request
References
Weblinks
- Line switch with other rocker marking
- Line switch on left of inlet
Alternative: polarized version or protection class I
CMF2,
CMF5; CMF3, CMF6
pdf datasheet, html-datasheet, General Product Information, Distributor-
Stock-Check, Accessories, Detailed request for product
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
2.5 A / 250 VAC; 50 Hz
6 A / 125 VAC; 60 Hz
> 2.3 kVAC between L-N
> 2.8 kVAC between L/N-PE
(1 min/50 Hz)
-25 °C to 70 °C
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class II acc. to IEC 61140
PCB 1.6 mm
Thermoplastic, black, UL 94V-0
appliance inlet/-outlet
C8 acc. to IEC 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C,
2.5 A, Protection Class II
Rocker switch 1-pole, non-illuminated,
acc. to IEC 61058-1
Technical Details
Line Switch
Allowable Operation Tempe-
rature
IP-Protection
Insulation cover
Terminal
Material: Housing
Approvals and Compliances
Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in
Details about
Approvals
Approvals
The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products.
Approval Reference Type: CMF
Approval Logo
Certificates
VDE Approvals
UL Approvals
CQC Approvals
Certification Body
VDE
UL
CQC
Description
VDE Certificate Number: 40018468
UL File Number: AXUT2&8.E96454
CCC Certificate Number: 2007010204227779
Connectors
1
CMF1, CMF4
Product standards
Product standards that are referenced
Organization
Design
Designed according to
Designed according to
Designed according to
Designed according to
Standard
IEC 60320-1
IEC 61058-1
UL 498
CSA C22.2 no. 42
Power entry modules without line filter
https://www.schurter.com /PG05
Description
Appliance couplers for household and similar general purposes
Switches for appliances. Part 1. General requirements
Standard for Attachment Plugs and Receptacles
General Use Receptacles, Attachment Plugs, and Similar Wiring Devices
Application standards
Application standards where the product can be used
Organization
Design
Designed for applications acc.
Standard
IEC/UL 60950
Description
IEC 60950-1 includes the basic requirements for the safety of information
technology equipment.
Compliances
The product complies with following Guide Lines
Identification
Details
CE declaration of conformity
Initiator
SCHURTER AG
Description
The CE marking declares that the product complies with the applicable
requirements laid down in the harmonisation of Community legislation on
its affixing in accordance with EU Regulation 765/2008.
EU Directive RoHS 2011/65/EU
The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March
2007. It is similar to the EU directive RoHS.
On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration,
Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as
"REACH") entered into force.
RoHS
China RoHS
REACH
SCHURTER AG
SCHURTER AG
SCHURTER AG
Dimensions [mm]
53.3
2.3
26.65
26.65
0.9
2.3
24.3
22.3
2
19
R
3
R
1
18
9
4
3
2.8
1.6
N
1.05
L
0.8
10.2 8.25
4
3
-0.1
0
1.3
0.8
2.4
2.8
8.6
18.45
45
±0.1
7 8.15
4.15
6.16 8
10
25.75
27.55
3
With insulation cover
The size of the mounting cut-out can be selected as required.
2
Connectors
11
Power entry modules without line filter
https://www.schurter.com /PG05
CMF1, CMF4
Drilling Diagram / CMF1 and CMF2
10.2
8.25 7
8.6
6.16
+0.1
1.6
0
Fixation on PCB or housing from
below
Fixation on PCB or housing from
above
14.3
1.6
+0.1
0
11
+0.15
1)
M3x12
4.2
±0.05
5.9
- 0.1
0
+0.30
1)
M3x12
3
3
10
11
±0.13
5.3
11
9
±0.1
13.4
D1
21.6
45
±0.1
28.05
3.2
23.4
1) self tapping screw
29.85
1.6
1) self tapping screw
D1 = 6.2 mm mounting from above
D1 = 3.6 mm mounting from below
All Variants
Connectors
C8
C8
C8
C8
█
Most Popular.
Mounting side
from below
from below
from top
from top
Cover
with cover
without cover
with cover
without cover
Ground terminal
Ground terminal direction
-
-
-
-
13
9
Order Number
CMF1.1131.12
CMF1.1031.12
CMF1.1111.12
CMF1.1011.12
█
Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
Packaging unit
50 Pcs
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
Connectors
3
11.09.2018