FEATURES
APPLICATIONS
Small Size
-
High Temperature
–
Low ESR – High Ripple Current
– Stable with Temperature – High Frequency
Power Units
–
LED Lighting
–
Telecommunications
Operating Temperature Range
Capacitance Tolerance
WVDC
Surge Voltage
SVDC
Dissipation Factor
120 Hz, 20°C
Leakage Current
Low Temperature
Stability
Impedance Ratio
(120 Hz)
16
25
-55°C to +125°C
+20% at 120 Hz, 20°C
35
50
63
100
1.15 x rated WVDC
12% MAX
2 Minutes
See standard part listing
160
-25°C/ +20°C
-55°C/ +20°C
<1.15
<1.25
2000 hours( 1500 Hours for WVDC>35V) at 125°C with rated WVDC applied
Capacitance Change
<30% of initial measured value
Dissipation Factor
<300% of maximum specified value
ESR
<300% of maximum specified value
Leakage Current
<100% of maximum specified value
1000 hours at 20°C with rated voltage applied at 90-95% R.H.
Capacitance Change
<20% of initial measured value
Dissipation Factor
<150% of maximum specified value
ESR
<150% of maximum specified value
Leakage Current
<100% of maximum specified value
1000 cycles at 125°C with rated surge voltage applied for 30 seconds through a
1kΩ resistor and discharged for 5 minutes and 30 seconds
Capacitance Change
<20% of initial measured value
Dissipation Factor
<150% of maximum specified value
ESR
<150% of maximum specified value
Leakage Current
<100% of maximum specified value
0.5% /1000 hours Maximum (60% confidence level at 125°C)
Load Life
Humidity test
Surge Voltage test
Failure Rate
Ripple Current Multipliers
120
.05
Frequency (Hz)
1k
10k
.3
.7
100k-300K
1.0
D+0.5
8
S+0.5
3.5
d
0.6
L
1
=L+1.5mm MAX
10
5.0
0.6
Feb-17