EEWORLDEEWORLDEEWORLD

Part Number

Search

109R0848K4D01

Description
FAN 80X25MM 48VDC LOCK
CategoryThermal management products   
File Size290KB,12 Pages
ManufacturerSANYO
Websitehttp://www.semic.sanyo.co.jp/english/index-e.html
Environmental Compliance
Download Datasheet Parametric View All

109R0848K4D01 Online Shopping

Suppliers Part Number Price MOQ In stock  
109R0848K4D01 - - View Buy Now

109R0848K4D01 Overview

FAN 80X25MM 48VDC LOCK

109R0848K4D01 Parametric

Parameter NameAttribute value
Voltage - Rated48VDC
size/dimensionsSquare - 80mm length x 80mm height
width25.00mm
airflow55.1 CFM(1.54m³/min)
Bearing typeball
Fan typeTube shaft type
characteristicLocked rotor sensor
noise41.0 dB(A)
Power (W)4.8W
RPM4600 RPM
Termination3 leads
Intrusion protection-
Operating temperature-4 ~ 140°F(-20 ~ 60°C)
ApprovalCSA,TUV,UL
voltage range40.8 ~ 55.2VDC
Material - Frameplastic
Material - Bladeplastic
Service life at different temperatures40,000 hours at 60°C
DC Fan
Wide lineup including low power consumption fans (9GA type), silent fans (9S type), and high airflow
and high static pressure fans.
Model Numbering System
Not every combination of the following codes or characters is available. Contact us for an available combination.
9GV
Type name
12
Frame size
12
Voltage
J
Speed code
1
Frame thickness
01
Sensor specifications
1
Frame form
Fans with PWM control function
9GV
Type name
12
Frame size
12
Voltage
P
PWM control function
4
Frame thickness
G
Speed code
Individual customer
spec
s
(2 to 4 digits)
01
9GE
Frame form
Type name
Frame size (mm)
9E
03
9P
04
9R
05
9A
06
9EC
08
9G
09
9GA 9GAX 9GV
12
13
14
9GX 9HV 9HVA
15
17
36
9S
9SG
20
ø
200
47
57
ø
172
×
147
ø
172
×
150
38
×
38 40
×
40 52
×
52 60
×
60 80
×
80 92
×
92 120
×
120 127
×
127 140
×
140 150
×
150
ø
172 36
×
36
(sidecut) (sidecut)
05
5
A B
0
70
12
12
C
1
38
24
24
D
48
48
E
2
32
F
etc.
G H
3
28
J
4
25
K
L M S W
etc.
6
20
7
15
9
10
D01 or D001
Voltage (V)
Speed code
Frame thickness (mm)
Sensor specifications
Frame form
5
50, 51
01 or 001
02 or 002
With a pulse sensor
Nil
Without a sensor
1
With a lock sensor
3
40
×
40
×
28 mm for 1U applications
Plastic frame: Ribbed frame
Plastic frame: Ribbed frame
Aluminum frame: Ribless frame
Plastic frame: Ribless frame
How to Read Specifications
(DC fan)
Model no.
Rated voltage Operating voltage range Rated current Rated input Rated speed
[V]
[V]
[A]
[W]
[min
-1
]
Max. airflow
[m³/min]
[CFM]
Max. static pressure
[Pa]
[inchH²O]
SPL
[dB (A)]
Operating temperature
[˚C]
Expected life
[h]
9GA0412G70 01
12
7 to 13.8
0.17
2.04
13100
0.36
12.7
192
0.77
42
-
20 to
+
70
40000/60˚C
(70000/40˚C)
Rated voltage
…………………
Operating voltage range
……
Rated current
…………………
Rated input
……………………
Rated speed
……………………
Max. airflow
……………………
Max. static pressure
…………
SPL
………………………………
Operating temperature
………
Expected life
……………………
This is the necessary voltage to drive the fan. E.g.) 12 VDC, 24 VDC, 48 VDC
The voltage range over which fan operation is guaranteed.
The current when the fan is operating at rated voltage (at free air).
The power value when the fan is operating at rated voltage (at free air).
The speed when the fan is operating at rated voltage (at free air).
The maximum airflow that the fan can generate during rated operation (measured with our double chamber measuring device).
Airflow is the volume of air generated by the fan per unit of time.
The maximum static pressure value that the fan can produce during rated operation (measured with our double chamber measuring device).
Static pressure indicates a fan's ability to move air against resistance due to the internal structure of the device to which the fan is installed.
SPL stands for Sound Pressure Level. The noise level during the fan's rated operation.
Please refer to the technical material section for the measurement method.
The temperature range over which fan operation is guaranteed (Non- condensing).
Service life hours that 90% of bearings will survive without failing when continuously operated at the rated voltage and 60˚C
temperature. Expected life at 40˚C is for reference only.
For more information, please refer to the technical material section.
11
DC Fan
DC
What does DIN VDE V 0884-11:2017-01 mean for digital isolator certification?
In January 2020 , the German Institute for Standardization ( DIN) and the Association of German Electrical Engineers (VDE) V0884-10: 2006-12 is no longer a valid certification standard for evaluating ...
qwqwqw2088 Analogue and Mixed Signal
Do CAN and LIN in automotive BCM and ECU need to be isolated? Do switching quantities need to be isolated? How to design grounding?
I just started working in the automotive electronics industry and I don't know the rules of this industry. I would like to ask the experts in this field to help me clear my ignorance. Thank you! In ad...
bingo888 Automotive Electronics
Let's take a look at how UWB compares to other standards
Recently, in the exploration of ultra-wideband (UWB) technology (part 1), UWB was compared with other standards. Let's take a look.There are many factors to consider when designing an indoor positioni...
alan000345 RF/Wirelessly
【Silicon Labs BG22-EK4108A Bluetooth Development Evaluation】+Connection Test Using Android APP
1. After setting up the development correctly, you can test whether the code can run correctly. A more convenient way is to download the EFR Connect Android app. After startup, enter the demo page, wi...
北方 Development Kits Review Area
How to encapsulate GPIO into nodes.
[color=#ff0000]A: How can I encapsulate a GPIO into a node of /sys/device/platform/rst. [/color] [color=#000000]B: Does it have to be in this directory /sys/device/platform/? Is there a way to only pu...
明远智睿Lan Industrial Control Electronics
[RVB2601 Creative Application Development] Simulating UART 3 to implement FIFO reception
The hardware serial port has a FIFO function, so the received data will be put into the buffer. Since the GPIO simulation has no buffer, I "copied" a FIFO work myself. fifi.c /**************FIFO Begin...
lugl4313820 XuanTie RISC-V Activity Zone

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号