EEWORLDEEWORLDEEWORLD

Part Number

Search

2035-09-C5

Description
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Sparkover100V/s 90V Miniature 2 Pole
CategoryCircuit protection   
File Size366KB,2 Pages
ManufacturerBourns
Websitehttp://www.bourns.com
Download Datasheet Parametric View All

2035-09-C5 Online Shopping

Suppliers Part Number Price MOQ In stock  
2035-09-C5 - - View Buy Now

2035-09-C5 Overview

Gas Discharge Tubes - GDTs / Gas Plasma Arrestors Sparkover100V/s 90V Miniature 2 Pole

2035-09-C5 Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerBourns
Product CategoryGas Discharge Tubes - GDTs / Gas Plasma Arrestors
RoHSN
Peak Pulse Current10 kA
DC Sparkover90 V
Number of Electrodes2 Electrode
Termination StyleAxial
Failsafe Protection Y/NFailsafe Not Protected
Diameter5 mm
Length4 mm
Minimum Operating Temperature- 55 C
Maximum Operating Temperature+ 85 C
TechnologyGas Discharge Tubes
Type2 Electrode Miniature Gas Discharge Tube
Mounting StyleThrough Hole
Insulation Resistance10 GOhms
Factory Pack Quantity100
Unit Weight0.352740 oz
*R
oH
VE S CO
AV R M
AI SIO PL
LA N IA
BL S NT
E
Features
n
5 mm diameter, 4 mm long (2035 series)
n
5 mm diameter, 5 mm long (2037 series)
n
UL Recognized
n
High surge current rating
n
Stable breakdown throughout life
n
RoHS compliant* versions available
M
PL
IA
NT
Applications
n
Telecommunications
n
Industrial electronics
n
Commercial electronics
n
Consumer electronics
n
Automotive, aircraft, military electronics
Characteristics
LE
AD
F
RE
E
Test Methods per ITU-T K.12, IEEE C62.31 and IEC 61643-311 GDT standards.
Characteristic
DC Sparkover ±15 %
Impulse Sparkover
(1)
100 V/µs
1000 V/µs
Characteristic
DC Sparkover ±15 % @ 100 V/s
Impulse Sparkover
(1)
100 V/µs
1000 V/µs
(1)
*R
oH
S
CO
2035/2037 Series - Miniature 2-Pole Gas Discharge Tube
2035-2037-09
2035/2037-15
2035/2037-20
Model No.
2035/2037-23
2035/2037-25
2035/2037-30
(±20 % for Model 2035/2037-09) @ 100 V/s
90 V
300 V
550 V
150 V
Ro VE LEA
HS RS D
C ION FRE
OM S E
PL AR
IA E
NT
*
200 V
425 V
575 V
230 V
450 V
600 V
2035/2037-42
250 V
475 V
625 V
2035/2037-47
300V
525 V
650 V
2035/2037-60
350 V
550 V
2035/2037-35
350 V
600 V
750 V
2035/2037-40
Model No.
420 V
675 V
850 V
400 V
650 V
800 V
470 V
750 V
950 V
600 V
950 V
1100 V
Impulse Sparkover voltage is defined as typical values of distribution.
Insulation Resistance (IR) ..................100 V (50 V for Models 2035/2037-09) .................................. > 10
10
Ω
Glow Voltage ......................................10 mA ..................................................................................... ~ 70 V
Arc Voltage .........................................1 A .......................................................................................... ~ 10 V
Glow-Arc Transition Current ............................................................................................................... < 0.5 A
Capacitance........................................1 MHz ..................................................................................... < 1 pF
DC Holdover Voltage
(2)
.....................135 V, (52 V for Models 2035/2037-09, .................................. < 150 ms
80 V for Models 2035/2037-15)
Impulse Discharge Current ................10000 A, 8/20 µs
(3)
................................................................. 1 operation min.
5000 A, 8/20 µs ...................................................................... > 10 operations
1000 A, 10/350 µs .................................................................. 1 operation
100 A, 10/1000 µs ................................................................. > 300 operations
100 A, 10/700 µs ................................................................... > 500 operations
Alternating Discharge Current ...........20 Arms, 11 cycles
(3)
.............................................................. 1 operation min.
5 Arms, 1 s ............................................................................. > 10 operations
Operating Temperature ...................................................................................................................... -55 to +85 °C
Climatic Category (IEC 60068-1)........................................................................................................ 40/90/21
Notes:
• UL recognized component, UL File E153537.
• Model number marking on tube: xxxV.
• Sparkover limits after life ±20 % (-25 %, +30 % for Models 2035/2037-09 and 2035/2037-60) , IR>10
8
Ω.
• Other DC sparkover ranges available on request.
• At delivery AQL 0.65 Level II, DIN ISO 2859.
(2)
(3)
Network applied.
DC Sparkover may exceed ±20 % but will continue to protect without venting.
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Users should verify actual device performance in their specific applications.

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号