OCL: Open Circuit Inductance test parameters: 100 kHz, 0.1 Vrms, 0.0 Adc.
(2)
Irms: DC current for an approximate
∆T
of 40 °C without core loss. Derating is
necessary for AC currents. PCB layout, trace thickness and width, air-flow, and
proximity of other heat generating components will affect the temperature rise. It
is recommended that the temperature of the part not exceed
+105
°C under
worst case operating conditions verified in the end application.
(3)
Isat Amperes peak for approximately 20% rolloff (@+20 °C)
(4)
Isat Amperes peak for approximately 30% rolloff (@+20 °C)
(5)
K-factor: Used to determine B p-p for core loss (see graph).
B p-p = K*L*∆I, B p-p: (Gauss), K: (K factor from table), L: (Inductance in uH),
∆(Peak
to peak ripple current in Amps).
Dimensions (mm)
TOP VIEW
FRONT VIEW
B
OTTOM VIEW
9.0
max
HCPT1309-xxx
wwllyy R
13.2 sq
MAX
2
3.5 +/- 0.5
1
"A " MAX
"B" +/- 1.0
"C" typ
SCHEMATIC
Dimension Table
Part No
HCPT1309-R20
HCPT1309-R47
HCPT1309-1R0
HCPT1309-1R5
HCPT1309-2R2
HCPT1309-3R3
RECOMMENDED PCB PAD LAYOUT
"D"
2.13
2.13
1.6
1.40
1.40
1.40
"B" +/- 1.0
ØD
"A "
14.0
14.0
13.7
13.5
13.5
13.5
"B"
12.2
12.2
12.0
11.8
11.8
11.8
"C"
1.63
1.63
1.29
1.15
1.15
1.15
1
Do not route traces or vias underneath the inductor
2
www.eaton.com/electronics
HCPT1309
High current power inductors
Technical Data
4138
Effective
July
2017
Core loss vs. Bp-p
160.00
140.00
120.00
200kHz
300kHz
400kHz
500kHz
600kHz
700kHz
800kH
900kHz
1.0MHz
Core Loss (mW)
100.00
80.00
60.00
40.00
20.00
0.00
250
500
750
1000
1250
1500
1750
2000
2250
2500
2750
B p-p (Gauss)
Inductance characteristics
OCL vs Isat
100
90
80
70
OCL (%)
60
50
40
30
20
10
0
0
20
40
60
80
% of Isat
100
120
140
160
www.eaton.com/electronics
3
Technical Data
4138
Effective
July
2017
HCPT1309
High current power inductors
Wave solder profile- Through-hole components
Reflow soldering not recommended
Life Support Policy: Eaton does not authorize the use of any of its products for use in life support devices or systems without the express written
approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly
used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user.
Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also
reserves the right to change or update, without notice, any technical information contained in this bulletin.