EEWORLDEEWORLDEEWORLD

Part Number

Search

6CKFS1

Description
6A, 120/250VAC, MALE, MAINS POWER CONNECTOR
CategoryThe connector    The power connector   
File Size317KB,2 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Download Datasheet Parametric View All

6CKFS1 Overview

6A, 120/250VAC, MALE, MAINS POWER CONNECTOR

6CKFS1 Parametric

Parameter NameAttribute value
MakerTE Connectivity
Reach Compliance Codeunknown
Is SamacsysN
Connector typeMAINS POWER CONNECTOR
Contact point genderMALE
Coupling typeSNAP
DIN complianceNO
IEC complianceNO
MIL complianceNO
Power Connector Ratings6A, 120/250VAC
Manufacturer's serial numberC
Installation typePANEL
Total number of contacts3
Base Number Matches1
C
Series
Switch with IEC Connector Compact Size
UL Recognized
CSA Certified
VDE Approved
C Series
Two function power entry module combining a DPST
switch and an IEC 320 power line connector. Compact
packaging allows a smaller panel cutout with choice of
snap-in or flange mounting. Available with general
purpose filtering (F models - CFS, CFE), medical
application filtering (H models - CHS, CHE) or unfiltered
(CS, CE). Terminals allow for easy connection to any
wiring scheme. Preconnected terminals from line to
switch are available (B Models - CBS, CBE) for reducing
OEM wiring time.
The medical versions (H models) are designed
specifically for health care applications. Their extremely
low leakage current allows compliance with UL544 and
UL2601 as well as CSA22.2 health care specifications for
use with both patient and non-patient care equipment.
The C series also has the adaptability to fit into existing
panel cutouts using snap-on extender options. Using the
CA430 extender, the panel cutout height is increased by
0.13”. (Extender is available pre-assembled using part
numbers with ‘K’ designation)
CFS
CS
Specifications
Hipot rating (one minute):
line-to-ground
line-to-line
Operating frequency:
Rated voltage:
Rated current:
Operating voltages:
Switch:
2250 VDC
1450 VDC
50/60 Hz
120/250 VAC
10A@120 VAC
10A @ 250 VAC
115/230 VAC
Rated for 10,000
operations at full load.
51 Amp inrush capability.
Unfiltered .187” x .032” terminals
Filtered
.25” x .032” terminals
Terminals:
Filtered Models Only:
Maximum leakage current, each line-to-ground
F models
H models
@ 120 VAC 60 Hz:
@ 250 VAC 50 Hz:
@ 120 VAC 60 Hz:
@ 250 VAC 50 Hz:
.25mA
.40mA
2µA
5µA
Electrical Schematic
F Models (CFS, CFE)
Minimum
insertion loss in dB:
Line-to-ground in 50 ohm circuit
Current
Frequency MHz
Rating
0.05 0.15 0.5
1
5
H Models
1A
3A
6A
10A
F Models
1A
3A
6A
10A
Note 2
Note 2
10
21
24
18
11
47
48
41
33
30
10
14
13
9
46
50
50
42
H Models (CHS, CHE)
16
9
4
2
10
8
4
1
21
14
10
6
26
16
11
4
37
31
22
10
46
32
22
14
44
32
23
15
48
36
27
18
26
26
19
11
46
43
36
27
B Models (CBS, CBE)
Note 1
Note 1
C
86
Power on/off
Resistor location for reference only.
Note 1: Jumpers provided on CBS and CBE versions.
Note 2: Location of optional filter.
Line-to-line in 50 ohm circuit
Current
Frequency MHz
Rating
0.05 0.15
0.5
1
5
H Models
1A
1
6
13
29
38
3A
1
5
10
22
36
6A
1
5
14
20
31
10A
1
4
11
19
32
F Models
1A
1
3
13
28
62
3A
2
6
14
23
65
6A
2
6
14
27
46
10A
1
7
14
23
42
10
42
34
33
37
67
65
48
44
30
26
36
37
38
42
67
58
62
www.cor.com - Libertyville, IL (847) 680-7400

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号