SCOPE:
FIXED/ADJUSTABLE, LOW POWER CMOS, STEP-UP SWITCHING REGULATOR
Generic Number
MAX631AM(x)/883B
MAX631BM(x)/883B
MAX632AM(x)/883B
MAX632BM(x)/883B
MAX633AM(x)/883B
MAX633BM(x)/883B
Device Type
01
02
03
04
05
06
Case Outline(s). The case outlines shall be designated in Mil-Std-1835 and as follows:
Outline Letter
MAXIM SMD
JA
P
Mil-Std-1835
GDIP1-T8 or CDIP2-T8
Case Outline
8 LEAD CERDIP
Package Code
J8
Absolute Maximum Ratings
Supply Voltage, V
OUT
....................................................................................................... +18V
Output Voltage, L
X
and LBO ........................................................................................... +18V
Input Voltage, LBI, VFB ..................................................................... -0.3V to (+V
OUT
+0.3V)
L
X
Output Current ............................................................................................... 450 mA Peak
LBO Output Current ........................................................................................................ 50mA
Lead Temperature (soldering, 10 seconds) ...........................................................……..... +300°C
Storage Temperature ..............................................................................………. -65°C to +150°C
Continuous Power Dissipation ..........................................................................…….....T
A
=+70°C
8 lead CERDIP(derate 8.0mW/°C above +70°C) .................................................……... 640mW
Junction Temperature T
J
....................................................................................………. +150°C
Thermal Resistance, Junction to Case
8 lead CERDIP,
ΘJC:
....................................................................................……….. 55°C/W
Thermal Resistance, Junction to Ambient
8 lead CERDIP.
ΘJA:
..................................................................................………. 125°C/W
Recommended Operating Conditions.
Ambient Operating Range (T
A
) ............................................................……... -55°C to
+125°C
Input Voltage Range (V
IN
).................................................................……... 2.4V dc to 16.5V dc
OutputVoltage Range (V
OUT
) ............................................................…….. 2.4V dc to 16.5V dc
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device.
These are stress ratings only, and functional operation of the device at these or any other conditions beyond
those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
----------------------------
Electrical Characteristics of MAX631/632/633/883B
for /883B and SMD 5962-92141
19-0231
Page 2 of
Rev. D
6
TABLE 1 ELECTRICAL TESTS
PARAMETER
Symbol
CONDITIONS
-55
°C
<=T
A
<= +125°C
V
IN
=+3.0V
Unless otherwise specified
Voltage at V
OUT
Voltage at V
OUT
L
X
Off, V
OUT
=+5V
L
X
Off, V
OUT
=+12V
L
X
Off, V
OUT
=+15V
Group A
Subgroup
Device
type
Limits
Min
1/
2.4
1.5
2.0
Limits
Max
1/
16.4
Units
Operating Voltage
Start-up Voltage
Supply Current
NOTE 2
Reference Voltage
Output Voltage
+V
S
V
SU
1,2,3
1
2,3
1,2,3
1
2,3
1,2,3
All
All
01,02
03,04
05,06
All
01
02
03
04
05
06
All
All
All
All
All
All
All
All
01
02
03
04
05
06
All
All
All
All
V
V
I
S
V
REF
V
OUT
No load, V
FB
=GND, NOTE 2
1.24
1.20
4.75
4.5
11.4
10.8
14.25
13.5
Line Regulation
Load Regulation
Oscillator Duty
Cycle
LX On Resistance
Low-Battery Input
Bias Current
Leakage Current
Low Battery Input
Threshold Voltage
Low-Battery
Output Current
VR
LINE
VR
LOAD
O
DC
R
LXON
I
LBI
I
LX
V
LBI
I
LBO
R3=816kΩ, R4=100kΩ
NOTE 3
3V<V
IN
<6V
R3=816kΩ, R4=100kΩ NOTE 3
V
IN
=6V, I
OUT
=1mA, 20mA
NOTE 2
I
X
=100mA, V
OUT
=5V
1,2,3
1,2,3
4
1
1
0.4
2.0
2.5
1.38
1.42
5.25
5.5
12.6
13.2
15.75
16.5
0.2
1.0
mA
µA
V
%/V
OUT
%/V
OUT
%
Ω
nA
µA
V
µA
40
60
12
10
1
100
1.44
V
LX
=16.5V
1
2,3
1
1,2,3
4
1.18
500
40
35
45.5
40
45.5
40
V
LBO
=0.4V, V
LBI
=1.18V
V
OUT
=+5V
50
60
kHz
56
65
56
65
10
1.0
140
3.0
Oscillator
Frequency Range
NOTE 2
f
O
V
OUT
=+12V
V
OUT
=+15V
4
4
1
VFB Input Bias
Current
Diode Forward
Voltage
On Resistance, CP
Leakage Current
Low Battery
Output Leakage
Current
I
FB
V
F
RCP
ON
I
LBOL
I
F
=100mA
V
OUT
=5.0V, I
OUT
=±10mA
V
LBO
=+16.5V, V
LBI
=+1.44V
nA
V
Ω
µA
1
1
1,2,3
----------------------------
Electrical Characteristics of MAX631/632/633/883B
for /883B and SMD 5962-92141
19-0231
Page 3 of
Rev. D
6
NOTE 1: The algebraic convention, whereby the most negative value is a minimum and the most positive a
maximum, is used in this table. Negative current shall be defined as conventional current flow out of
a device terminal.
NOTE 2: S1 set to B and S2 open provides a nominal output voltage of 5 volts for device types 01 and 02;
12 volts for device types 03 and 04; 15 volts for device types 05, 06.
NOTE 3: R3 and R4 give a nominal output voltage of 12 volts with S1 set to A and S2 closed.
ORDERING INFORMATION
01
02
03
04
04
05
MAXIM PART NUMBER
MAX631AMJA/883B
MAX631BMJA/883B
MAX632AMJA/883B
MAX632BMJA/883B
MAX633AMJA/883B
MAX633BMJA/883B
SMD NUMBER
5962-9214101MPA
5962-9214102MPA
5962-9214103MPA
5962-9214104MPA
5962-9214105MPA
5962-9214106MPA
TERMINAL NUMBER
1
2
3
4
5
6
7
8
8 LEAD CERDIP
LBI
LBO
GND
LX
VOUT
CP
V
FB
COMP
----------------------------
Electrical Characteristics of MAX631/632/633/883B
for /883B and SMD 5962-92141
19-0231
Page 4 of
Rev. D
6
QUALITY ASSURANCE
Sampling and inspection procedures shall be in accordance with MIL-Prf-38535, Appendix A as specified in Mil-
Std-883.
Screening shall be in accordance with Method 5004 of Mil-Std-883. Burn-in test Method 1015:
1. Test Condition, A, B, C, or D.
2. TA = +125°C minimum.
3. Interim and final electrical test requirements shall be specified in Table 2.
Quality conformance inspection shall be in accordance with Method 5005 of Mil-Std-883, including Groups A, B,
C, and D inspection.
Group A inspection:
1. Tests as specified in Table 2.
2. Selected subgroups in Table 1, Method 5005 of Mil-Std-883 shall be omitted.
Group C and D inspections:
a. End-point electrical parameters shall be specified in Table 1.
b. Steady-state life test, Method 1005 of Mil-Std-883:
1. Test condition A, B, C, D.
2. TA = +125°C, minimum.
3. Test duration, 1000 hours, except as permitted by Method 1005 of Mil-Std-883.
TABLE 2.
ELECTRICAL TEST REQUIREMENTS
Mil-Std-883 Test Requirements
Subgroups
per Method 5005, Table 1
1
1*, 2, 3, 4
1, 2, 3, 4
1
Interim Electric Parameters
Method 5004
Final Electrical Parameters
Method 5005
Group A Test Requirements
Method 5005
Group C and D End-Point Electrical Parameters
Method 5005
*
PDA applies to Subgroup 1 only.
----------------------------
Electrical Characteristics of MAX631/632/633/883B
for /883B and SMD 5962-92141
19-0231
Page 5 of
Rev. D
6