THRU-HOLE POWER INDUCTORS
AIUR-07, AIUR-08 SERIES
| | | | | | | | | | | | | | |
FEATURES:
• Ferrite core with heat shrink tube
• High Reliability
STANDARD SPECIFICATIONS:
Part
Number
AIUR-07
100K
120K
150K
180K
220K
270K
330K
390K
470K
0.18±0.02
4,6±0,5
OPTIONS:
• Bulk Pack is standard
APPLICATIONS:
• Electronic Appliance
• Noise Filtering
I
DC
(A)
Max
0.6
0.6
0.5
0.5
0.4
0.4
0.4
0.3
Part
Number
AIUR-07
271K
331K
391K
471K
561K
681K
821K
102K
R
DC
(
Ω
)
Max
2.0
2.2
2.6
3.0
3.5
4.7
5.3
6.3
I
DC
(A)
Max
0.3
0.3
0.2
0.2
0.2
0.18
0.17
0.15
L (µH)
10
12
15
18
22
27
33
39
47
R
DC
(
Ω
)
Max
0.10
0.12
0.13
0.14
0.16
0.19
0.25
0.28
0.32
I
DC
(A)
Max
1.5
1.4
1.3
1.1
1.0
0.9
0.8
0.8
0.7
Part
Number
AIUR-07
560K
680K
820K
101K
121K
151K
181K
221K
L (µH)
56
68
82
100
120
150
180
220
R
DC
(
Ω
)
Max
0.37
0.46
0.54
0.66
0.87
1.03
1.26
1.39
L (µH)
270
330
390
470
560
680
820
1000
PHYSICAL CHARACTERISTICS:
0.16±0.04
4,0±1,0
0.157
4,00
TECHNICAL INFORMATION:
• Test frequency: 10µH-82µH = 2.52 MHz 100µH-1000µH = 1 KHz
• Tolerance: K = ±10% (Standard)
• Letter suffix indicates standard tolerance
• Temperature: -40°C to +125°C with no load -40°C to +85°C with full rated current
• Marking: Value and tolerance
• L drops 10% typical @ IDC from initial value
• Check SCD for detail E&M specification
Ø0.24±0.02
Ø6,0±0,5
Ø0.020
Ø0,50
STANDARD SPECIFICATIONS:
Part
Number
AIUR-08
100K
120K
150K
180K
220K
270K
330K
390K
470K
0.39±0.02
10,0±0,5
L (µH)
10
12
15
18
22
27
33
39
47
R
DC
(
Ω
)
Max
0.022
0.023
0.026
0.033
0.037
0.048
0.055
0.073
0.083
0.16±0.01
4,0±0,3
2
3
I
DC
(A)
Max
5.3
4.9
4.4
4.0
3.6
3.3
2.9
2.7
2.5
Part
Number
AIUR-08
560K
680K
820K
101K
121K
151K
181K
221K
L (µH)
56
68
82
100
120
150
180
220
R
DC
(
Ω
)
Max
0.092
0.12
0.14
0.16
0.20
0.23
0.31
0.34
I
DC
(A)
Max
0.6
0.6
0.5
0.5
0.4
0.4
0.4
0.3
Part
Number
AIUR-08
271K
331K
391K
471K
561K
681K
821K
102K
L (µH)
270
330
390
470
560
680
820
1000
R
DC
(
Ω
)
Max
0.40
0.52
0.65
0.71
1.00
1.10
1.30
1.70
I
DC
(A)
Max
1.00
0.93
0.86
0.78
0.71
0.65
0.59
0.53
PHYSICAL CHARACTERISTICS:
0.14±0.04
3,5±1,0
TECHNICAL INFORMATION:
• Test frequency: 10µH-82µH = 2.52 MHz 100µH-1000µH = 1 KHz
• Tolerance: K = ±10% (Standard)
• Letter suffix indicates standard tolerance
• Temperature: -40°C to +125°C with no load -40°C to +85°C with full rated current
• Marking: Value and tolerance
• L drops 10% typical @ IDC from initial value
• Check SCD for detail E&M specification
Ø0.39±0.02
Ø10,0±0,5
Ø0.024
Ø0,60
0.20±0.01
5,0±0,3
1
4
2
3
2
1
3
4
1 4
10µH~33µH
39µH~1mH
ABRACON IS
ISO 9001 / QS 9000
CERTIFIED
rev1.1-8/04
30332 Esperanza, Rancho Santa Margarita, California 92688
tel 949-546-8000
|
fax 949-546-8001
| www.abracon.com