Industrial and process control, distributed power, medical, ATE, communications, defense
and aerospace.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Product Overview
These DC-DC converter modules use advanced
power processing, control and packaging
technologies to provide the performance,
flexibility, reliability and cost effectiveness of a
mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V24A12T400BL2
24A
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
= - 10 to +100 - 20 to +125
C
= - 20 to +100 - 40 to +125
T
= - 40 to +100 - 40 to +125
H
= - 40 to +100 - 55 to +125
M
= - 55 to +100 - 65 to +125
B
Output Power
P
OUT
200W, 264W
300W, 400W
400W
300W
300W, 400W, 500W
300W, 400W
300W, 400W, 500W
300W, 400W, 500W
300W, 400W
300W, 400W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Product Type
V
= Standard
S
= Enhanced
efficiency
(avail.
≤12
V
OUT
only)
Output Voltage
3V3
= 3.3V
5
= 5V
6.5
= 6.5V
8
= 8V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
36
= 36V
48
= 48V
V
OUT
3.3V
5V
6.5V
8V
12V
15V
24V
28V
36V
48V
24V Maxi Family
Page 1 of 15
Rev 6.8
06/2017
vicorpower.com
800 927.9474
24V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
14.8
36.3
17.5
15.3
37.8
39.6
4.0
Min
18
Typ
24
Max
36
50
17.9
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
Notes
These modules will operate at up to 75% of rated power down
to 16V
IN
after start up at >18V
IN
<100ms
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
%
%
% / °C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to -OUT, +Sense to -OUT – Absolute Maximum Ratings
3.3V
5V
6.5V
8V
12V
15V
24V
28V
36V
48V
-0.5 to 4.7
-0.5 to 7.0
-0.5 to 9.0
-0.5 to 10.9
-0.5 to 16.1
-0.5 to 20.0
-0.5 to 31.7
-0.5 to 36.9
-0.5 to 47.2
-0.5 to 62.9
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 10.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20263)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.08
0.07
4.9
1.1
165
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
24V Maxi Family
Page 2 of 15
Rev 6.8
06/2017
vicorpower.com
800 927.9474
24V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
During normal operation
Switch must be able to sink
≥4mA.
See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Remote sense (total drop)
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
6.5
(184.3)
7.4
(209.3)
100
3000
1500
500
10
7.3
(207.5)
8.2
(232.5)
115
cURus, cTÜVus, CE
8.1
(230.7)
9.0
(255.7)
Min
Typ
Max
0.5
Unit
V
DC
V
RMS
V
RMS
V
RMS
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
0.25V per leg (sense leads must be connected to
respective, output terminals)
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
Temperature limiting
Agency approvals
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
24V Maxi Family
Page 3 of 15
Rev 6.8
06/2017
vicorpower.com
800 927.9474
24V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
3.3V
OUT
, 264W (e.g. S24A3V3C264BL, V24A3V3C264BL)
Parameter
Efficiency
S24A3V3C264BL (enhanced efficiency)
V24A3V3C264BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.0
80.0
4.14
Typ
86.0
81.4
75
4.3
8
±0.02
92
92
Max
Unit
%
94
4.46
12
±0.2
80
108
108
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
81.6
56
3.3V
OUT
, 200W (e.g. S24A3V3C200BL, V24A3V3C200BL)
Parameter
Efficiency
S24A3V3C200BL (enhanced efficiency)
V24A3V3C200BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.0
73.9
4.48
Typ
86.0
79.9
43
4.65
6.2
±0.02
69.7
69.7
Max
Unit
%
54
4.82
10
±0.2
60.6
81.9
81.9
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
61.8
42.4
5V
OUT
, 400W (e.g. S24A5C400BL, V24A5C400BL)
Parameter
Efficiency
S24A5C400BL (enhanced efficiency)
V24A5C400BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
84.0
80.0
6.03
Typ
86.5
84.5
152
6.25
6.8
±0.02
92
92
Max
Unit
%
190
6.47
10.1
±0.25
80
104
104
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
81.6
56
5V
OUT
, 300W (e.g. S24A5C300BL, V24A5C300BL)
Parameter
Efficiency
S24A5C300BL (enhanced efficiency)
V24A5C300BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.5
82.5
6.03
Typ
84.4
84.4
120
6.25
7.2
±0.02
69
69
Max
Unit
%
150
6.47
8.8
±0.2
60
81
81
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
61.2
42
24V Maxi Family
Page 4 of 15
Rev 6.8
06/2017
vicorpower.com
800 927.9474
24V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
6.5V
OUT
, 400W (e.g. S24A6V5C400BL, V24A6V5C400BL)
Parameter
Efficiency
S24A6V5C400BL (enhanced efficiency)
V24A6V5C400BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
85.0
85.0
7.7
Typ
86.1
86.1
220
7.98
9.2
±0.02
70.7
70.7
Max
Unit
%
275
8.26
10.5
±0.2
61.5
83.1
83.1
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
62.7
43
8V
OUT
, 300W (e.g. S24A8C300BL, V24A8C300BL)
Parameter
Efficiency
S24A8C300BL (enhanced efficiency)
V24A8C300BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.6
85.6
9.36
Typ
86.5
86.5
215
9.7
8.7
±0.02
43.1
43.1
Max
Unit
%
269
10.1
13.9
±0.2
37.5
50.7
50.7
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
38.2
26.2
12V
OUT
, 500W (e.g. S24A12C500B, V24A12C500BL)
Parameter
Efficiency
S24A12C500B (enhanced efficiency)
V24A12C500BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.7
86.0
13.8
Typ
88.2
87.5
272
14.3
10.8
±0.02
47.9
47.9
Max
Unit
%
340
14.8
12.0
±0.2
41.67
56.3
56.3
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
42.5
29.2
12V
OUT
, 400W (e.g. S24A12C400BL, V24A12C400BL)
Parameter
Efficiency
S24A12C400BL (enhanced efficiency)
V24A12C400BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.0
87.0
13.7
Typ
89.5
88.3
250
14.3
6.8
±0.02
38.4
38.4
Max
Unit
%
320
14.9
10.2
±0.2
33.33
43.5
43.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
[size=4] μC/OS-II is an open source, compact, and preemptive real-time kernel embedded development system. The code is short, clear, and has high real-time and security performance. Most of the code i...
# Interpretation of FFT data of IPC communication of TL5708 development board **Table of Contents** [TOC] ## 1. The actual set waveform parameters The signal input to the DSP core is as follows: Initi...
Wireless communication has already penetrated into people's lives. There are more and more companies designing wireless modules, and more and more friends are engaged in RF design. The following are s...
Foreign netizens use MSP432 launchpad and CC1100 to make wireless sensor nodes, transmit data to CC3200 wireless gateway through sub 1G, and use energia (similar to Arduino) software for programming. ...
Servo control method
There are three control modes: speed control, torque control, and position control. Speed control and torque control are both controlled by analog quantity, and position...[Details]
1 Introduction
The National College Students "Freescale Cup" Intelligent Car Competition, held in China since 2006, integrates science, fun and appreciation. It is a scientific and technologica...[Details]
This article records the operation process of mini2440 lighting up the LED; Light up an LED code implementation method: assembly and C; Conducted some functional expansion experiments; The basic id...[Details]
If the signal frequency is in the microwave range, the wide range of H, Y and Z parameters (used in basic network theory) cannot be measured for the following reasons: Difficult to measure the total...[Details]
This time, Nidec Power Systems Co., Ltd. (former Nidec Tosei), a group company of Nidec Corporation, has developed a new product for electric oil pumps used to cool the "E-Axle" drive motor system of...[Details]
This article will introduce you to the basics of stepper motors, including their working principle, construction, control methods, uses, types, and their advantages and disadvantages.
St...[Details]
Today's portable electronic products are very rich in functions. For example, watches can be used as TV remote controls, mobile phones can also be used as digital cameras and calculators, MP3 players...[Details]
According to the Nikkei, TSMC has decided to build its first overseas R&D base in Tsukuba, Ibaraki Prefecture, Japan. It is reported that TSMC will also set up a subsidiary in the local area with an ...[Details]
On the arm microprocessor hardware platform, the tornado integrated development environment of windriver company is applied to realize the embedded application system of automatic sending multimedi...[Details]
Flame-retardant cable is a commonly used cable product. After a fire occurs, it can limit the burning to a local area, prevent it from spreading, and protect other equipment to avoid greater losses. T...[Details]
There are many types of current light control instruments, such as light intensity measuring instruments, but they have many disadvantages such as unstable performance, low sensitivity, complicated p...[Details]
Yesterday on the train back home, I took a copy of "Craftsman's Notes" and read a few articles. I benefited a lot. One of the articles talked about programming ideas, that is, how to start building a...[Details]
Users who often watch the 100 episodes of practical videos of the ZDS2022 oscilloscope may have known that we recently shared with you the reference waveform function of the ZDS2022. A customer repl...[Details]
In the past,
LED
manufacturers
have developed large-size
LED chips
to achieve their expected goals in order to fully profit from the
white light LED
beam. However, in f...[Details]
As the number one player in the field of hydrogen fuel cells, Toyota has always had the problem of being unpopular. At present, Toyota is adjusting its promotion strategy for hydrogen fuel cell techn...[Details]