FEATURES
Multiple Case Sizes
-
High Voltage
–
High Current
APPLICATIONS
Bulk Filtering
–
Switching Power Supplies
Operating Temperature Range
Capacitance Tolerance
WVDC
Surge Voltage
SVDC
WVDC
Dissipation
Factor
tan δ
(120 Hz)
Leakage Current
@20°C, Rated WVDC applied
Impedance Ratio
(120 Hz)
WVDC
-25°C/+20°C
-40°C/+20°C
-40°C to +105°C (<100WVDC)
-25°C to +105°C (>160WVDC)
+20% at 120 Hz, 20°C
10
13
10
.6
16
25
35
50
63
80
100 160 200 250 350
400
20
32
44
63
79
100 120 200 250 300 400
450
16
25
35
50
63
80
100 160 200 250 350
400
.45
.3
.25
.2
.15
.15
.15
.15
.15
.15
.15
.2
For capacitances above 33000uF, add to DF value (Capacitance-33000) *0.1
10000
450
500
450
.2
Time
10
6
15
16
6
15
5 Minutes
3√CV
450
8
-
25
35
50
63
80
100 160 200 250 350 400
6
6
4
3
3
3
8
8
8
8
8
15
15
15
15
15
-
-
-
-
-
5000 hours at 105°C with rated WVDC and ripple current applied
<20% of initial measured value
<200% of maximum specified value
<100% of maximum specified value
Load Life
Capacitance change
Dissipation factor
Leakage current
Capacitance Change
Dissipation Factor
Leakage Current
60
0.9
0.8
0.8
120
1.0
1.0
1.0
400
1.0
1.0
1.0
1k
1.15
1.25
1.3
1000 hours at 105°C with no voltage applied
Shelf Life
<20% of initial measured value
<200% of maximum specified value
<100% of maximum specified value
Frequency (Hz)
Ripple Current
Multipliers
WVDC
<100
160<V<250
>350
10k
1.25
1.47
1.47
50k
1.25
1.47
1.47
45
2.4
2.4
2.4
Temperature (°C)
65
2.1
2.1
2.1
75
1.9
1.9
1.9
85
1.7
1.7
1.7
105
1
1
1
Feb-17