EEWORLDEEWORLDEEWORLD

Part Number

Search

64-30321-CC-0300

Description
Interconnection Device
CategoryThe connector   
File Size171KB,2 Pages
ManufacturerGould Fiber Optics
Download Datasheet Parametric View All

64-30321-CC-0300 Overview

Interconnection Device

64-30321-CC-0300 Parametric

Parameter NameAttribute value
MakerGould Fiber Optics
Reach Compliance Codeunknown
Is SamacsysN
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
www.gouldfo.com
T hi s i s th e N e w Po w e r of Go u l d
!
1121 Benfield Blvd., Millersville, MD 21108
Toll Free: 800-54-GOULD
VOICE: 410.987.5600 FAX: 410.987.1201
EMAIL: info@gouldfo.com WEB: www.gouldfo.com
Patch Cords
Gould cable assemblies feature quality parts and guaranteed performance specifications.
• Specifications are per mated pair at both 1310nm and 1550nm.
Connector Insertion/Return Loss Specifications for Singlemode Fiber
End Number
Connector
Insertion Loss Typical Return Loss
2=
ST
< 0.50dB
>50dB
3=
FC
< 0.35dB
>50dB
4=
SC
< 0.35dB
>50dB
5=
LC
< 0.35dB
>40dB
6=
FC/APC
< 0.35dB
>60dB
7=
SC/APC
< 0.35dB
>60dB
DATA SHEET- Patch Cords
ORDERING INFORMATION
Product Number
6___- ___ ___ ___ ___ ___ - ___ ___ - ___ ___ ___ ___ 1
Patchcord
Type
2= singlemode
4= multimode
Testing Requirements
0= Insertion Loss testing data only
1= Insertion Loss and Return Loss testing data
2= Insertion Loss and Endface Geometry data
3= Insertion Loss, Return Loss
and Endface Geometry data
Fiber Type
03=Corning SMF-28, 100 Kpsi proof test on fiber
06= Corning Flexcore (5/125)
11= 50/125 Graded Index (Corning)
12= 62.5/125 Graded Index (Corning)
22= 200/230/500, 0.37NA SI MM HCS (Lucent)
23= 200/230/500, 0.48NA SI MM HCS (Lucent)
25= 100/140/250 Step Index (Lucent)
27= Corning Flexcore (7/125)
32= Corning SMF-28, 200 Kpsi proof test on fiber
54= Corning Flexcore (7/125), 200 Kpsi proof test on
fiber
Connector
End A
2= ST/UPC
3= FC/UPC
4= SC/UPC
5= LC/UPC
6= FC/APC
7= SC/APC
A= LC/APC
B= MU/UPC
C= MU/APC
Length in meters xx.xx
i.e.., 3 meters=0300
Connector
End B
0= Pigtail
Assembly
2= ST/UPC
3= FC/UPC
4= SC/UPC
5= LC/UPC
6= FC/APC
7= SC/APC
A= LC/APC
B= MU/UPC
C= MU/APC
Buffer Type
10= No buffering (not recommended!)
11= 900 micron, white, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
12= 900 micron, orange, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
13= 900 micron, blue, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
15= 900 micron, green, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
19= 900 micron, yellow, PVDF (Temp. rating –40 to +85
°C,
UL 94V-0 Rated)
21= 900 micron, white, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
22= 900 micron, orange, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
23= 900 micron, blue, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
24= 900 micron, red, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
25= 900 micron, green, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
26= 900 micron, black, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
27= 900 micron, brown, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
28= 900 micron, gray/slate, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
29= 900 micron, yellow, hytrel (Temp. rating –20 to +70
°C,
UL 94V-HM Rated)
31= 2.9 mm x 0.4mm, Kevlar Reinforced Tubing, yellow
32= 2.9 mm x 0.4 mm, Kevlar Reinforced Tubing, orange
33= 2.9 mm x 0.9 mm, Kevlar Reinforced Tubing, orange
34= 2.9 mm x 0.45 mm, Kevlar Reinforced Tubing, black
01/09/03
The difference between multilayer PCB and LTCC
What are the advantages and disadvantages of traditional multi-layer PCB technology and LTCC technology? In addition to the fact that LTCC can embed filters, I can't think of any advantages of LTCC ov...
明天你好123 PCB Design
The basis of the difference between TTL and CMOS
[align=left][size=4][color=#000000][backcolor=white]1, TTL level: [/backcolor][/color][/size] [size=4][color=#000000][backcolor=white]Output high level>2.4V, output low level=2.0V, input low levelcmos...
Jacktang Analogue and Mixed Signal
About Puzhong Technology 51 microcontroller development board v3.0, LED part of the problem
#include typedef unsigned char u8; typedef unsigned int u16; void delay(u16 i) { while(i--); } u8 a[]={0x18,0x24,0x42,0x81,0x42,0x24,0x18}; What does this line mean? , mainly used to implement somethi...
gbjkjku 51mcu
Understanding bandwidth
I have been exposed to bandwidth for a long time, but it seems that I have never figured it out. Today, I checked Baidu Encyclopedia and found that it solved many of my doubts. Here are some excerpts:...
Jacktang Analogue and Mixed Signal
Circuit output grounding problem.
There are three groups of circuits as shown in the figure (the 6291 above has only one group). If the 1st PIN of CN1 is connected to DGND by mistake during the test, what may happen? There are also so...
hau30729 Power technology
When AD software needs to drill vias to connect the network in the inner electrical layer segmentation, what is the minimum distance between the vias and the inner electrical layer segmentation edge?
When I used AD software to design a 6-layer board, I found a phenomenon. My fourth layer is the POWER layer, which divides the system power supply. When I need to drill vias for network connection, I ...
fangmian211 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号