EEWORLDEEWORLDEEWORLD

Part Number

Search

10134250-005LF

Description
DIN Rail Terminal Blocks SCREW TERMINAL BLOCK 2.5- YELLOW-GREEN
CategoryThe connector   
File Size130KB,1 Pages
ManufacturerFCI / Amphenol
Download Datasheet Parametric View All

10134250-005LF Overview

DIN Rail Terminal Blocks SCREW TERMINAL BLOCK 2.5- YELLOW-GREEN

10134250-005LF Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerFCI / Amphenol
Product CategoryDIN Rail Terminal Blocks
PackagingTray
Factory Pack Quantity100
Part number description :
10134250-XXXLF
LF: Lead Free, RoHs compliant, see note
XXX : Color ref or/and version
PN
10134250-001LF
3
10134250-002LF
3
10134250-003LF
3
10134250-004LF
3
10134250-005LF
3
10134250-006LF
3
10134250-007LF
3
10134250-008LF
3
10134250-009LF
3
10134250-010LF
3
Colour
grey
black
blue
brown
yellow-green
green
yellow
orange
red
white
 Version
TECHNICAL DATA / DIMENSIONS
H
S
Dimensions
e
Width mm
h
Length mm
Height mm
h
Mounting type (EN 60715)
n
Technical data
h
Maximum load current
m
Insulating material
a
Self-extinguishing degree acc. to UL94
e
e
Rated surge voltage
d
Pollution degree
Surge voltage category
e
Insulating material group
a
Nominal Voltage
i
Nominal Current
i
Connection data
n
Conductor cross-section solid min/max
d
m
Conductor cross-section stranded min/max
d
AWG min/max
G
Max conductor cross-section stranded with
d
ferrule with plastic sleeve
Stripping length
p
Screw
w
Tightening torque
APPROVALS
R
5.0
0
47.0
36.0
Omega TH35
m
24A
PA
A
V2
2
8kV
3
III
I
1000V
24A
0.50 / 4 mm
5
2
0.50 / 4 mm
5
24-12AWG
2.5 mm / L=12 m m
max 9 mm
M2.6
0,5Nm / 4. 0 Lb.-In
5
n
2
2
5
47
Note : THIS PRODUCT MEETS EUROPEAN UNION DIRECTIVES
AND OTHER COUNTRY REGULATIONS AS PER GS-47-0004
ACCESSORIES
Description
e
Item
Marking
k
10134398-001LF
3
10134398-002LF ÷
3
10134398-011LF
3
10134398-012LF ÷
3
10134398-041LF
3
10134399-001LF
3
10134400-001LF
4
10134392-001LF
3
10134393-001LF
3
10134394-001LF
3
10134395-001LF
3
10134387-001LF
3
10134389-001LF
3
10134390-001LF
3
10134391-001LF
3
10134259-001LF
2
10134263-001LF
2
10134273-001LF
2
10134273-002LF
2
10134273-003LF
2
10134271-001LF
2
10134276-001LF
2
10134276-002LF
2
Blank single-digit marking tags
n
n
k
Printed single-digit marking tags numbered : 1÷0
n
k
Printed single-digit marking tags with letter: A
÷Z
n
Marking tag adapter
r
Blank Marking tags
n
Steel Omega Rail TH35x7,5mm -2mt length
e
Slotted Steel Omega Rail TH35x7,5mm -2mt length
t
a
Steel Omega Rail TH35x15mm -2mt length
e
Slotted Steel Omega Rail TH35x15mm -2mt length
t
a
Angled support bracket
g
End Bracket for TH35 Omega rail -Width 9mm
d
m
End Bracket for TH35 Omega rail -Width 6mm
d
m
Fast-snap End Bracket for TH35 Omega rail
s
End Plate for SCREW Terminal Blocks 2.5/4
4
Separator for SCREW Terminal Blocks 2.5/4
4
Jumper bar 2 poles, pitch 5,1mm J2,5
c
Jumper bar 3 poles, pitch 5,1mm J2,5
c
Jumper bar 24 poles, pitch 5,1mm J2,5
t
Ratchet Cutting Tool for jumper bar J2,5 -orange
a
Red test plug adapter
Black test plug adapter
36
RINA
AWG 24-12 – 600V – 20A
W
0
EN60947-7-1 2.5mm – 1000V – 24A
2
DIN RAIL system - Mounting and Installation material
d
Additional items
i
Registration has ended | GigaDevice GD32E231 DIY Contest! 100 development boards free to try + great gifts!
Competition details page:GigaDevice GD32E231 DIY Competition, unlimited inspiration!Registration time: From now on to April 21, 2019The world of GD32E231 series development boards● Value-added MCU ● A...
EEWORLD社区 GD32 MCU
After downloading the program with the emulator, the program cannot be run if the emulator is unplugged
I recently wrote an AD acquisition program using IAR. The MCU is msp430F1611. It can run normally when running at full speed with the emulator. However, after disconnecting the emulator and powering t...
Shakuras Microcontroller MCU
Here is the DDS information on the national competition list
The list is out and can be seen here: https://en.eeworld.com/bbs/thread-1084541-1-1.html Welcome everyone to guess the questions: https://en.eeworld.com/bbs/thread-1084544-1-1.htmlList of component in...
okhxyyo Electronics Design Contest
Operational Amplifier Selection and Requirements
1. Common-mode input resistance (RINCM) This parameter indicates the ratio of the input common-mode voltage range to the change in bias current within this range when the operational amplifier operate...
fish001 Analogue and Mixed Signal
The most comprehensive electronic product structure design rules
https://download.eeworld.com.cn/detail/mamselc/603956...
arui1999 Download Centre

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号