CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation
of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
NOTES:
2. For up to 4 outputs per device, add
±25mA
for each additional output.
3. Unless otherwise specified, all voltages are referenced to ground.
4.
θ
JA
is measured with the component mounted on an evaluation PC board in free air.
DC Electrical Specifications
TEST
CONDITIONS
PARAMETER
AC TYPES
High Level Input Voltage
V
IH
-
-
1.5
3
4.5
5.5
Low Level Input Voltage
V
IL
-
-
1.5
3
4.5
5.5
High Level Output Voltage
V
OH
V
IH
or V
IL
-0.05
-0.05
-0.05
-4
-24
-50
(Note 6, 7)
1.5
3
4.5
3
4.5
5.5
1.2
2.1
3.15
(Note 5)
3.85
-
-
-
-
1.4
2.9
4.4
2.58
3.94
(Note 5)
-
-
-
-
-
0.3
0.9
1.35
(Note 5)
1.65
-
-
-
-
-
-
1.2
2.1
3.15
(Note 5)
3.85
-
-
-
-
1.4
2.9
4.4
2.4
3.7
(Note 5)
3.85
-
-
-
-
0.3
0.9
1.35
(Note 5)
1.65
-
-
-
-
-
-
V
V
V
V
V
V
V
V
V
V
V
V
V
V
SYMBOL
V
I
(V)
I
O
(mA)
V
CC
(V)
25
o
C
MIN
MAX
-55
o
C TO 125
o
C
MIN
MAX
UNITS
2
CD54AC02F3A, CD54ACT02F3A
DC Electrical Specifications
(Continued)
TEST
CONDITIONS
PARAMETER
Low Level Output Voltage
SYMBOL
V
OL
V
I
(V)
V
IH
or V
IL
I
O
(mA)
0.05
0.05
0.05
12
24
50
(Note 6, 7)
Input Leakage Current
Quiescent Device Current
ACT TYPES
High Level Input Voltage
Low Level Input Voltage
High Level Output Voltage
V
IH
V
IL
V
OH
-
-
V
IH
or V
IL
-
-
-0.05
-24
-50
(Note 6, 7)
Low Level Output Voltage
V
OL
V
IH
or V
IL
0.05
24
50
(Note 6, 7)
Input Leakage Current
Quiescent Device Current
Additional Supply Current per
Input Pin TTL Inputs High
1 Unit Load
NOTES:
5. Tested at 100%.
6. Test one output at a time for a 1-second maximum duration. Measurement is made by forcing current and measuring voltage to minimize
power dissipation.
7. Test verifies a minimum transmission-line-drive capability of 75Ω for 54AC/ACT Series.
I
I
I
CC
∆I
CC
V
CC
or
GND
V
CC
or
GND
V
CC
-2.1
-
0
-
4.5 to 5.5
4.5 to 5.5
4.5
4.5
5.5
4.5
4.5
5.5
5.5
5.5
4.5 to 5.5
2
(Note 5)
-
4.4
3.94
(Note 5)
-
-
-
-
-
-
-
-
0.8
(Note 5)
-
-
-
0.1
0.36
(Note 5)
-
±0.1
(Note 5)
4
(Note 5)
2.4
2
(Note 5)
-
4.4
3.7
(Note 5)
3.85
-
-
-
-
-
-
-
0.8
(Note 5)
-
-
-
0.1
0.5
(Note 5)
1.65
±1
(Note 5)
80
(Note 5)
3
V
V
V
V
V
V
V
V
µA
µA
mA
I
I
I
CC
V
CC
or
GND
-
0
25
o
C
MIN
-
-
-
-
-
-
-
-
MAX
0.1
0.1
0.1
0.36
0.36
(Note 5)
-
±0.1
(Note 5)
4
(Note 5)
-55
o
C TO 125
o
C
MIN
-
-
-
-
-
-
-
-
MAX
0.1
0.1
0.1
0.5
0.5
(Note 5)
1.65
±1
(Note 5)
80
(Note 5)
UNITS
V
V
V
V
V
V
µA
µA
V
CC
(V)
1.5
3
4.5
3
4.5
5.5
5.5
5.5
ACT Input Load Table
INPUT
All
UNIT LOAD
0.32
NOTE: Unit load is
∆I
CC
limit specified in DC Electrical Specifications
Table, e.g., 2.4mA max at 25
o
C.
3
CD54AC02F3A, CD54ACT02F3A
Switching Specifications
Input t
r
, t
f
= 3ns, C
L
= 50pF (Worst Case)
-55
o
C TO 125
o
C
PARAMETER
AC TYPES
Propagation Delay, Input to Output
t
PLH,
t
PHL
1.5
3.3 (Note 9)
5 (Note 10)
Input Capacitance
Power Dissipation Capacitance
ACT TYPES
Propagation Delay, Input to Output
Input Capacitance
Power Dissipation Capacitance
NOTES:
8. Limits tested at 100%.
9. 3.3V Min at 3.6V, Max at 3V.
10. 5V Min at 5.5V, Max at 4.5V
11. C