.085 in. (2.16mm)
Density
Miniature Ribbon
Solder Cup
Metal Shell
Terminates Discrete Wire (loose or jacketed cable) with ultra-low-resistance solder connections.
■
Metal shell provides grounding and shielding capability.
■
Available in plug and socket styles in 14, 24, 36, and 50 position sizes.
■
F
EATURES
M
ATERIALS
E
NVIRONMENTAL
■
■
Designed for panel mount, 180° (Top-Entry), or 90° (Standard) / 270° (Reverse) End-Entry
cable applications.
All plugs lock with InstaLatch passive latch feature for automatic latching.
■
Industry-standard bail latch feature available for locking/unlocking without tools in applications
such as SCSI-1 and Centronics.
■
UL Recognized - Files E170218 (UL1977), E130965 (UL1863).
■
CSA Approved - File LR31996-7
.
Insulator:
Blue UL94V-0 rated diallyl phthalate type MDG, per MIL-M14F
Contact:
Copper alloy
Contact Plating:
Select gold over 50µin. select nickel standard;
30µin. select gold over 50µin. select nickel available where indicated
Shell:
Steel
Shell Plating:
Zinc with clear chromate coating
Operating Temperature:
-40°C to +105°C
Shock:
50G Peak, per EIA Std. RS364, TP27, Condition A
Vibration:
3 cycles @ 10-55Hz in each of 3 axes per EIA Std. 364, TP28, Condition A
Moisture Resistance:
Per EIA Std. RS364, TP31, Condition B, with Step 7B excluded
Voltage Rating:
500 VAC @ sea level; 125 VAC @ 70,000 ft.
1200 VAC RMS @ sea level, per EIA Std. RS364, TP20
5 Amps (4 Amps per CSA)
6 Milliohms maximum, per EIA Std. RS364, TP6
5000 Megohms minimum initial;
1000 Megohms minimum after moisture
E
LECTRICAL
Withstanding Voltage:
Contact Rating:
Contact Resistance:
Insulation Resistance:
Durability:
200 mating/unmating cycles
Mating / Unmating Forces:
Mating Force (max.)
Unmating Force (min.)
Size
Lb.
Kg
Lb.
Kg
14
5
2.27
2
0.91
24
8
3.63
4
1.81
36
12
5.44
6
2.72
50
15
6.80
7
3.18
Termination:
Each contact accepts maximum 22 AWG solid wire or maximum 24 AWG
stranded wire
M
ECHANICAL
Call Toll Free: 1 (800) 323-9612
6-24
.085 in. (2.16mm)
Density
Miniature Ribbon
Panel Mount
Solder Cup
Metal Shell
“Panel mount” products are connectors without hoods. They are typically used to provide signal I/O from a
system panel or cabinet, where strain relief to a cable jacket is not required.
•
Available with high barrier insulators that extend beyond the end of the solder cup, physically isolating
adjacent contacts.
Standard versions have .103" mounting holes (sockets have .103" with float bushings) for use with #3
hardware, or .185" mounting holes for use with #8 hardware.
Select sizes are available with .120" mounting holes for use with #4 hardware, or with integral panel
clips, which allow snap-in front mounting for more cost-effective assembly.
Bail latching sockets are available, as are bail latching plugs. While the plugs would not be panel-
mounted, they are available for premold/solder overmolding applications.
•
•
•
See page 6-4 for recommended standard panel cutout dimensions.
See page 6-51 for accessories such as mounting screws and dust covers, which make the use of Cinch
Miniature Ribbon connectors even more cost-effective in panel-mount applications.
See the appropriate cable connector section that follows for products that include hoods for
exposed-cable applications.
Dimensions
A
Size
14
24
36
50
in
1.750
2.175
2.685
3.260
mm
44.45
55.25
68.20
82.80
in
1.417
1.842
2.352
2.947
B
mm
35.99
46.79
59.74
74.85
C
in
0.910
1.335
1.845
2.440
mm
23.11
33.91
46.86
61.98
B
Max.
A
Max.
B
Max.
A
Max.
6-25
Call Toll Free: 1 (800) 323-9612
.085 in. (2.16mm)
Density
Miniature Ribbon
Through Hole
Solder Cup
Metal Shell
Bail Latches
Integral Panel Clips
Float Mounts
Ordering Information, Panel Mount
Plug, InstaLatching
No Barrier
Size
Commercial
14
57-10140
.103 Hole
24
57-10240
36
57-10360
50
57-10500
14
57-10140-185
.185 Hole
24
57-10240-4
36
57-10360-22
50
57-10500-48
.120 Hole
50
-
Integral Panel Clips*, .103 Hole
50
-
Bail Latching
36
-
Tin-Plated Shells
50
-
†
IEEE 1284-B (for foil wrap & overmold applications)
Mount
30Au/Ni
57-10140A
57-10240A
57-10360A
57-10500A
57-10140-185A
57-10240-4A
57-10360-22A
57-10500-48A
-
-
-
-
High Barrier
Commercial
30Au/Ni
57-10140-6
57-10140-6A
57-10240-6
57-10240-6A
57-10360-14
57-10360-14A
57-10500-6
57-10500-6A
-
-
-
-
-
-
-
-
57-10500-120
57-10500-120A
57-10500-41
57-10500-41A
57-10360-28†
57-10360-28A†
57-10500-79
57-10500-79A
Socket
No Barrier
Latch
Mount
Float Mounts with
.103 Hole
No latches
Size
14
24
36
50
14
24
36
50
50
50
14
24
36
50
Commercial
57-20140
57-20240
57-20360
57-20500
57-20140-4
57-20240-2
57-20360-3
57-20500-15
-
-
57-40140
57-40240
57-40360†
57-40500
30Au/Ni
57-20140A
57-20240A
57-20360A
57-20500A
57-20140-4A
57-20240-2A
57-20360-3A
57-20500-15A
-
-
57-40140A
57-40240A
57-40360A†
57-40500A
High Barrier
Commercial
30Au/Ni
57-20140-6
57-20140-6A
57-20240-6
57-20240-6A
57-20360-10
57-20360-10A
57-20500-6
57-20500-6A
-
-
-
-
-
-
-
-
57-20500-120
57-20500-120A
57-20500-41
57-20500-41A
57-40140-HB
57-40140-HBA
57-40240-HB
57-40240-HBA
57-40360-9†
57-40360-9A†
57-40500-4
57-40500-4A
57-40500-28†
57-40500-28A†
6
.185 Hole
.120 Hole
Integral Panel Clips*, .103 Hole
Bail latches
.116 Hole
.116 Hole with
Tin-Plated Shell
50
57-40500-5
57-40500-5A
* Integral Panel Clips, for front-mount only, require modified panel cutout. See page 6-52 for details.
†
IEEE 1284-B
Call Toll Free: 1 (800) 323-9612
6-26
.085 in. (2.16mm)
Density
Miniature Ribbon
180° (Top-Entry) Cable
Solder Cup
Metal Shell
Top-Entry products include a connector, hood, and associated hardware. They are typically used at the end of a cable, where it
is subject to physical strain and protection of the termination area is required.
•
•
•
Plug
Includes all hardware required to attach hood to connector.
Bail latching sockets have latch hardware integral to connector body, making cable assembly less costly.
Bail latching plugs include notches that lock with industry-standard bail-lock sockets.
Socket
Dimensions
A
Size
14
24
36
50
in
1.417
1.842
2.352
2.947
mm
35.99
46.79
59.74
74.85
in
1.750
2.175
2.685
3.270
B
mm
44.45
55.25
68.20
83.06
in
.306
.473
.639
.766
C
mm
7.77
11.10
16.23
19.46
in
1.495
1.920
2.431
3.025
D
mm
37.97
48.77
61.75
76.84
in
.843
.825
.905
.995
E
mm
21.41
20.96
22.99
25.27
in
.306
.473
.640
.766
F
mm
7.77
12.01
16.26
19.46
in
.422
.473
.473
.473
G
mm
10.72
12.01
12.01
12.01
Ordering Information, 180° (Top-Entry) Cable
Plug, InstaLatching
Mount
Bail Latching
Size
14
24
36
50
50
Commercial
57-30140
57-30240
57-30360
57-30500
57-30500-4
No Barrier
30Au/Ni
57-30140A
57-30240A
57-30360A
57-30500A
57-30500-4A
High Barrier
Commercial
30Au/Ni
-
-
-
-
-
-
57-30500-3
57-30500-3A
-
-
6
#4-40 Holes for captive screw
Socket
Mount
With Bail Latches
Size
14
24
36
50
Commercial
57-60140
57-60240
57-60360
57-60500
No Barrier
30Au/Ni
57-60140A
57-60240A
57-60360A
57-60500A
High Barrier
Commercial
30Au/Ni
-
-
-
-
-
-
-
-
6-27
Call Toll Free: 1 (800) 323-9612
.085 in. (2.16mm)
Density
Miniature Ribbon
Solder Cup
Metal Shell
90° (Standard) / 270° (Reverse) End-Entry Cable
End-Entry connectors, available in 50 position size only, include a hood and integral cable clamp for cable exit from the end of
the connector
• The standard-orientation plug has the cable clamp on the position 1/26
end, and the standard-orientation socket has the clamp on the position
25/50 end.
• Cables may be extended end-to-end (i.e., “running cable”) by mating
standard-orientation plugs and sockets, or “doubled back” by mating a
standard-orientation connector with a reverse-orientation mate.
• Cables may exit either direction on a cable-to-panel application by
choosing standard- or reverse-orientation, depending on the desired
direction of cable exit.
• Include screw that is 5/8" long, suitable for locking directly to the body
of another connector. For locking to connectors panel-mounted
with screw-lock hardware, shorter screws are required. See page 6-51
for these and other accessories, such as dust covers.
Double-Back Cable Application
Running Cable Application
Ordering Information, End-Entry
Plug, InstaLatching (High Barrier, with Dust Cover)
6
Mount
High (Standard) Hood
Low-Profile Hood
Size
50
50
Standard (90°) Orientation
Commercial
30Au/Ni
57-10500-14
57-10500-14A
57-10500-7
57-10500-7A
Reverse (270°) Orientation
Commercial
30Au/Ni
57-10500-270
57-10500-270A
57-10500-271
57-10500-271A
Socket (High Barrier, with Dust Cover)
Standard (90°) Orientation
Commercial
30Au/Ni
57-20500-7
57-20500-7A
57-20500-19
57-20500-19A
Reverse (270°) Orientation
Commercial
30Au/Ni
57-20500-270
57-20500-270A
57-20500-271
57-20500-271A
Mount
High (Standard) Hood
Low-Profile Hood
Size
50
50
Call Toll Free: 1 (800) 323-9612
6-28