Three jacket layers and two steel tape armor layers
Provide superior rodent resistance for direct-buried ap-
plications
Flexible, craft-friendly buffer tubes
Facilitate easy routing in closures
Cable core features innovative waterblocking tech-
nology
Eliminates the need for traditional flooding compound
and provides efficient and craft-friendly cable preparation
Medium-density polyethylene jacket
Makes cable rugged and durable while being flexible and
easy to strip
Exceeds the RDUP requirements for mid-span buffer
tube slack storage
Provides flexibility for mid-span access applications
ALTOS
®
gel-free triple-jacket, double-armored cables are
rugged armored cables designed for direct-buried instal-
lations. The loose tube design provides stable perfor-
mance over a wide temperature range and is compatible
with any telecommunications-grade optical fiber.
Standards
Design and Test Criteria
ANSI/ICEA S-87-640
Telcordia GR-20
RDUP PE-90
ALTOS Triple-Jacket, Double-Armored Cables, 72
Fibers, Enhanced
| Photo PIM0573
Family Spec Sheet 0046_NAFTA_AEN
Page 1 | Revision date 2014-07-01
ALTOS Triple-Jacket, Double-Armored Cables, 216
Fibers, Enhanced
| Photo PIM0577
ALTOS
®
Triple-Jacket, Double-Armored
Cables, 12-216 Fibers, Enhanced
Polyethylene (PE)
Outer Jacket
Water-Swellable
Tape
Corrugated Steel
Armor
Water-Swellable
Tape
Water-Swellable
Tape
Fiber
Ripcord
Buffer
Tube
Dielectric Central
Element
Polyethylene (PE)
Inner Jacket
Polyethylene (PE)
Middle Jacket
Corrugated Steel
Armor
Polyethylene (PE)
Outer Jacket
Water-Swellable
Tape
Corrugated Steel
Armor
Water-Swellable
Tape
Water-Swellable
Tape
Fiber
Ripcord
Buffer
Tube
Dielectric Central
Element
Water-Swellable
Tape
Polyethylene (PE)
Inner Jacket
Polyethylene (PE)
Middle Jacket
Corrugated Steel
Armor
ALTOS Triple-Jacket, Double-Armored Cables, 72
Fibers, Enhanced
| Photo PIM1472
ALTOS Triple-Jacket, Double-Armored Cables, 216
Fibers, Enhanced
| Photo PIM1476
Specifications
Temperature Range
Storage
Installation
Operation
-40 °C to 70 °C (-40 °F to 158 °F)
-30 °C to 70 °C (-22 °F to 158 °F)
-40 °C to 70 °C (-40 °F to 158 °F)
*
Note: Corning recommends storing indoor/outdoor cable in a proper temperature environment prior to installation to allow the cable temperature to meet instal-
lation temperature range specifications for best installation results.
Max. Tensile Strength, Short-Term
Max. Tensile Strength, Long-Term
2700 N (600 lbf)
890 N (200 lbf)
Mechanical Characteristics Cable
Fiber Count Product
Type
12 - 72
96
Armored
Armored
Maximum
Fibers per
Tube
12
12
Number of
Tube Posi-
tions
6
8
Number
of Active
Tubes
1-6
8
Weight
Nominal
Outer Dia-
meter
18.3 mm
(0.72 in)
20 mm
(0.79 in)
Min. Bend
Radius
Installation
275 mm
(10.8 in)
300 mm
(11.8 in)
Min. Bend
Radius
Operation
183 mm
(7.2 in)
200 mm
(7.9 in)
310 kg/km
(208 lb/1000 ft)
361 kg/km
(242 lb/1000 ft)
Family Spec Sheet 0046_NAFTA_AEN
Page 2 | Revision date 2014-07-01
ALTOS
®
Triple-Jacket, Double-Armored
Cables, 12-216 Fibers, Enhanced
Mechanical Characteristics Cable
Fiber Count Product
Type
144
192 - 216
Armored
Armored
Maximum
Fibers per
Tube
12
12
Number of
Tube Posi-
tions
12
18
Number
of Active
Tubes
12
16 - 18
Weight
Nominal
Outer Dia-
meter
23.8 mm
(0.94 in)
24 mm
(0.94 in)
Min. Bend
Radius
Installation
357 mm
(14.1 in)
360 mm
(14.2 in)
Min. Bend
Radius
Operation
238 mm
(9.4 in)
240 mm
(9.4 in)
487 kg/km
(327 lb/1000 ft)
473 kg/km
(317 lb/1000 ft)
Chemical Characteristics
RoHS
Free of hazardous substances according to RoHS 2002/95/
EG
Transmission Performance
Multimode
Fiber Core Diameter
(
µm
)
Fiber Category
Fiber Code
Performance Option Code
Wavelengths
(
nm
)
Maximum Attenuation
(
dB/km
)
Serial 1 Gigabit Ethernet
(
m
)
Serial 10 Gigabit Ethernet
(
m
)
Min. Overfilled Launch (OFL)
Bandwidth
(
MHz*km
)
Minimum Effective Modal
Bandwidth (EMB)
(
MHz*km
)
62.5
OM1
K
30
850/1300
3.4/1.0
300/550
33/-
200/500
220/-
50
OM2
T
31
850/1300
3.0/1.0
750/500
150/-
700/500
950/-
50
OM3
T
80
850/1300
3.0/1.0
1000/600
300/-
1500/500
2000/-
50
OM4
T
90
850/1300
3.0/1.0
1100/600
550/-
3500/500
4700/-
Family Spec Sheet 0046_NAFTA_AEN
Page 3 | Revision date 2014-07-01
ALTOS
®
Triple-Jacket, Double-Armored
Cables, 12-216 Fibers, Enhanced
Single-mode
Fiber Name
Fiber Category
Fiber Code
Performance Option Code
Wavelengths
(
nm
)
Maximum Attenuation
(
dB/km
)
Typical Attenuation*
(
dB/km
)
Fiber Name
Fiber Category
Fiber Code
Performance Option Code
Wavelengths
(
nm
)
Maximum Attenuation
(
dB/km
)
Typical Attenuation*
(
dB/km
)
SMF-28e+
®
fiber
G.652.D
E
01
1310/1383/1550
0.4/0.4/0.3
0.33/0.33/0.19
LEAF
®
G.655
F
01
1310/1383/1550
-/-/0.25
-/-/0.19
SMF-28e+
®
fiber
G.652.D
E
00
1310/1383/1550
0.35/0.35/0.25
0.33/0.33/0.19
SMF-28
®
ULL
G.652
P
19
1310/1383/1550
0.33/-/0.19
0.31/-/0.17
SMF-28e+
®
LL
G.652.D
L
22
1310/1383/1550
0.34/0.34/0.22
0.32/0.32/0.18
SMF-28
®
Ultra**
ClearCurve
®
XB**
G.652.D/G.657.A1 G.652.D/G.657.A1
Z
22
1310/1383/1550
0.34/0.34/0.22
0.32/0.32/0.18
H
01
1310/1383/1550
0.4/0.4/0.3
0.35/0.35/0.20
*
Typical attenuation values match the attenuation values listed in the optical fiber specifications. See
www.corning.com/opticalfiber
for Corning optical fiber
specifications. Better attenuation performance options are available for some fiber and cable types. Contact Customer Care for additional fiber options.
*
* SMF-28
®
Ultra and ClearCurve
®
XB fiber deliver up to 10x better macrobend loss performance compared to the G.652.D standard and up to 33 percent better
macrobend loss performance than the G.657.A1 standard for 10mm radii bends.
Family Spec Sheet 0046_NAFTA_AEN
Page 4 | Revision date 2014-07-01
ALTOS
®
Triple-Jacket, Double-Armored
Cables, 12-216 Fibers, Enhanced
Ordering Information |
Note: Contact Customer Care at 1-800-743-2675 for other options.
1) Cable outer diameter may change. Example: 48 F cable with 6 fibers per tube will require 8 active buffer and have an OD like a standard 96 F cable.
Corning Optical Communications LLC • PO Box 489 • Hickory, NC 28603-0489 USA
[i=s]This post was last edited by full_stack on 2022-6-26 10:48[/i]Embedded Studio is a powerful C/C++ IDE (Integrated Development Environment) for microcontrollers. It is designed to provide users wi...
[i=s]This post was last edited by bjemt on 2018-12-27 13:20[/i] [align=left][color=#008000][backcolor=transparent][font=Tahoma,&][size=16px]I received the Rapid IoT prototype module today. It is small...
5. BG22 power consumption test
In our previous article, we introduced the Bluetooth function of BG22. In fact, in addition to the function, we are most concerned about the power consumption of Bluetoo...
"Meeting users' needs for safe fast charging 'anytime, anywhere' has always been vivo's goal." To this end, vivo not only needs to continuously upgrade its technology to improve the charging speed an...[Details]
Many companies are willing to invest a lot of money in purchasing test and measurement instruments and equipment. High-speed digital circuit or system design teams often spend a lot of money on pu...[Details]
TMS320DM642 is selected as the system CPU, and the latest video coding standard H.264 compression algorithm is adopted to realize the wireless video monitoring and video data storage system based o...[Details]
If you want to change the pin that the LED is connected to, please modify the hardware.h file. If you want to change the brightness of the LED, please modify the Timings section definition in globa...[Details]
Institutional data shows that from January to April 2023, the installed capacity of power batteries in other global markets except the Chinese market was 86.7GWh, a year-on-year increase of 49.4%. ...[Details]
NI’s software-defined test and measurement platform provides mixed-signal functional test solutions for the brains of autonomous vehicles September 24, 2019 - National Instruments (NI), a provider...[Details]
The above picture shows the NVIDIA PX2 architecture, which is highly similar to Tesla . FSD can be seen as Parker and GPU combined into one, eliminating the very expensive PCIe switch. The PHY or ...[Details]
Tip 1 - Ensure accurate, reproducible results Measure with confidence with a complete solution Assembling a mmWave network analyzer “on your own” can be cumbersome and time-consuming. Worse, there is...[Details]
A single-chip microcomputer is a complete computer system integrated on a single chip. Although most of its functions are integrated on a small chip, it has most of the components required for a comp...[Details]
1. Development of MSP430 microcontroller
The MSP430 series is a 16-bit, ultra-low power hybrid microcontroller with a streamlined instruction set. It was launched in 1996. It has become a shining...[Details]
1 Introduction
Since digital signals have only two conditions, high level and low level, a single-chip microcomputer (MCU) can directly realize the acquisition and logic analysis of multiple digi...[Details]
The STM8S timer TIM4 consists of an 8-bit auto-reloadable up-counter with a programmable prescaler. The clock source of TIM4 is the system master clock f MASTER . Since f MASTER comes from HSE, HSI...[Details]
Servo motors, also known as actuator motors, are used as actuators in automatic control systems to convert received electrical signals into angular displacement or angular velocity output on the mo...[Details]
This article introduces a new method for measuring the Young's modulus of metal wire by using a photoelectric sensor. The key to this measurement is to accurately measure the tiny length change of the...[Details]
On November 4, the reporter learned from Hefei Power Supply Company that the functional application of Hefei's virtual power plant platform is constantly deepening. By vigorously expanding access reso...[Details]