Series XV
Single Output to 30A 420 Vac
No Heat Sink, Hybrid Relay
Part Number
XV46D30K
Description
30A, 420 Vac
Part Number Explanation
XV
46
D
30
K
NOTES
1) Line Voltage (nominal): 46 = 420 Vac
2) Switch Type: D = Zero-cross turn-on
3) Control Range: K = 20–30 Vdc,
*C = 12 Vdc also available
MECHANICAL SPECIFICATION
M4
1.10 (28)
Ø.19 (Ø4.7)
FEATURES/BENEFITS
• Industry standard package
• Combines the best of solid-state and
electromechanical relays
• Tight zero-cross window for low EMI
• Control LED
• Internal output protection
• High immunity to surges
DESCRIPTION
The Series XV relay combines the best of solid-state
and electromechanical technology. The relay is
designed in a touch-proof hockey-puck package. The
XV relay switches current up to 30A without a heat
sink. Visual control status is provided as a standard.
Elimination of the heat sink conserves space and
makes the XV ideal for numerous applications.
APPLICATIONS
• Interface applications
• Heating Control
• Light/Lamp control
• Contactor driver
• Fan speed control
• HVAC controls
APPROVALS
Model XV46D30K is UL recognized.
UL File Number: E128555.
WEIGHT: 5.64 oz (160g)
1.70 (43.2)
.35 (9)
1.87 (47.6)
1.00 (25.4)
1.77 (45)
1.75 (44.5)
M3.5
Figure 1 – XV relay; dimensions in inches (mm)
INPUT (CONTROL) SPECIFICATION
Min
Control Range*
Input Current Range
Must Turn-Off Voltage
Input Resistance (Typical)
Reverse Voltage Protection
Control Frequency
TYPICAL APPLICATION
20
31
Max
30
41
10
640
30
1
Units
Vdc
mAdc
Vdc
Ohms
Vdc
Hz
.27
(6.8)
2.41 (61.3)
CONTROL CHARACTERISTIC
45
40
A1+
t3
Input Current (mA)
35
30
25
20
15
10
SSR
t2
T
1
Vc
A1-
Supply
t1
EMR
V
L
L
1
Load
LED
5
0
0
5
10
15
20
25
30
35
Figure 2 – XV relay
Control Voltage (V)
Figure 3 – XV relay
© 2003 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
XV 1
XV\032003\Q1
Series XV
OUTPUT (LOAD) SPECIFICATION
Min
Operating Range
Peak Voltage
Load Current Range
Motor Load Current
(See Figure 4)
On-State Voltage Drop
Zero-Cross Window (Typical)
Off-State Leakage Current (60Hz)
Turn-On Time (60Hz)
Turn-Off Time (60Hz)
Off-State dv/dt
Maximum di/dt (Non-repetitive)
Operating Frequency
I
2
t for fuse matching (<8.3ms)
40
240
0.1
12
Max
420
800
30
7.5
Apeak
0.3
±12
2
12
20
500
50
440
288
V
V
mA
ms
ms
V/µs
A/µs
Hz
A
2
S
4
10
6
Operations
0
1
10
100
1000
SURGE CURRENT
Unit
Vrms
Vpeak
Arms
Apeak
200
250
Arms
150
Maximum Surge Current Rating (Non-Repetitive)
100
50
Number of Cycles
Figure 4 – XV relay
LIFETIME EXPECTANCY
5
At maximum rated current
(Resistive load)
ENVIRONMENTAL SPECIFICATION
Min
Operating Temperature
Storage Temperature
Input-Output Isolation
Output-Case Isolation
Life Expectancy
–40
–40
Max
90
100
4000
4000
See Figure 5
Unit
°C
°C
Vrms
V
3
2
1
0
100
200
300
400
500
Load Voltage (V)
Figure 5 – XV relay
NOTES:
1. Electrical Specifications at 25°C unless otherwise specified.
2. For 800Hz applications, contact factory.
3. For additional/custom options, contact factory.
XV 2
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2003 TELEDYNE RELAYS
XV\032003\Q1