CORCOM Product Guide
High Performance Filters for High Current Three Phase Applications
ADT Series
UL Recognized
ADT6/ADT6S
ADT Series
Designed with very high insertion loss for Delta
applications, these three phase filters work well in industrial
applications to bring high current motor drives into
compliance with the European EMC Directives.
The series offers filters between 63 and 200 amps at 480
VAC phase-to-phase. It is available with common or
differential mode (S models) coils for the correct protection
to fit the application.
Specifications
Maximum leakage current, each line-to-ground
ADT6/ADT6S
63ADT6S
Hipot rating (one minute):
line-to-ground
line-to-line
Operating frequency:
Rated voltage:
phase-to-phase:
phase-to-ground:
0.76A/2.7A @ 230V 50 Hz
1.5A @ 230V 50 Hz
2250 VDC
2160 VDC
50/60 Hz
480 VAC
277 VAC
Electrical Schematics
ADT6
Typical insertion loss in dB:
Line-to-ground in 50 ohm circuit:
Current
Rating
0063ADT6
0100ADT6
0160ADT6
0200ADT6
063ADT6S
100ADT6S
160ADT6S
200ADT6S
LOAD
.01
45
45
45
45
28
38
37
35
.1
85
85
80
77
45
60
58
54
Frequency-MHz
1
10
30
95 100 100
90 100 100
90 100 100
88 100 100
90
90
90
95 100 100
85 100 100
80 100 100
100
100
100
100
100
90
100
100
100
300
100
100
100
100
90
100
100
100
LINE
Line-to-line in 50 ohm circuit:
ADT6S
Current
Rating
0063ADT6
0100ADT6
0160ADT6
0200ADT6
063ADT6S
100ADT6S
160ADT6S
200ADT6S
LOAD
.01
35
43
44
43
35
43
44
43
.1
100
100
100
100
100
100
100
100
Frequency-MHz
1
10
30
100 100 100
100 100 100
100 100 100
100 100 100
100 100 100
100 100 100
100 100 100
100 100 100
100
100
100
100
100
100
100
100
100
300
100
100
100
100
100
100
100
100
LINE
10
Catalog 1654001
Revised 03-04
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
1-508-992-4495
Germany:
49-89-6089-0
www.cor.com
www.tycoelectronics.com
CORCOM Product Guide
High Performance Filters for High Current Three Phase Applications
(Continued)
ADT Series
RFI Power Line Filters
Case Style
A
E
Case Dimensions
Part No.
63ADT6
A
(max)
B
(max)
10.00
254.0
10.00
254.0
10.00
254.0
11.00
279.4
10.00
254.0
13.00
330.2
C
(max)
3.50
89.0
4.50
114.3
4.50
114.3
4.50
114.3
4.50
114.3
4.50
114.3
D
± .030
± .76
E
(max)
10.00
254.0
15.00
381.0
15.00
381.0
15.00
381.0
15.00
381.0
18.00
457.2
1.18 x .56
Cutout
2.00
50.8
1.00
25.4
.69
17.5
14.00
355.6
19.00
63ADT6S
482.6
19.00
100ADT6
482.6
19.00
100ADT6S
482.6
19.00
160/200ADT6
482.6
160/200ADT6S
22.00
558.8
3/8 - 16 Steel
8.50
216.0
8.50
216.0
8.50
216.0
8.50
216.0
8.50
216.0
11.50
292.2
Part Numbers
1.00
25.4
2.00
50.8
.75
19.0
063ADT6
100ADT6
160ADT6
200ADT6
063ADT6S
100ADT6S
160ADT6S
200ADT6S
DB
C
Terminals:
63ADT6, 63ADT6S, 100ADT6S:
Torque (Max.): 70 in.lb.
3/8-16 (6)
100ADT6, 160ADT6, 160ADT6S, 200ADT6, 200ADT6S: 7/16-20 (6)
Torque (Max.): 125 in.lb.
11
Catalog 1654001
Revised 03-04
Dimensions are in inches and
millimeters unless otherwise
specified. Values in italics
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA Cust. Svc.: 1-800-468-2023
CORCOM Prods: 1-847-680-7400
1-508-992-4495
Germany:
49-89-6089-0
www.cor.com
www.tycoelectronics.com