pHE850
• Emi suppressor, class y2, metallized polypropylene
• 0.001 – 1.0 µf, 300 vac, +110 °c
• new, small dimensions including low profile capacitors
L
RoHS
Compliant
B
tYpiCaL appLiCations
The capacitors are intended for use as
interference suppressors in Y2 (line-to-
earth) applications.
Not for use in series with the mains.
See www.kemet.com for more information.
ConstRuCtion
Winding of metallized polypropylene.
Encapsulated in self-extinguishing material
meeting the requirements of UL 94V-0.
p
∅
d
H
0.5
l
tECHniCaL data
rated voltage
capacitance range µf
temperature range °c
climatic category iEc
capacitance tolerance
approvals
dissipation factor tanδ
300 VAC, 50/60 Hz (
ENEC,UL,cUL
)
0.001–1.0
–55/+110
55/110/56/B
± 20% standard, other tolerances on request
ENEC, UL, cUL
Maximum values at +23 °C
C
≤
0.1 µF 0.1 µF < C
≤
1 µF
1 kHz
0.2%
0.15%
10 kHz
0.3%
0.4%
100 kHz
0.6%
–
C
≤
0.33 µF:
≥
30 000 MΩ
C
>
0.33 µF:
≥
10 000 s
Tabulated self-resonance frequencies f
0
refer to 5 mm
lead lengths.
The 100% screening factory test is carried out at 5000
VDC and 2500 VAC. The voltage level is selected to meet
the requirements in applicable equipment standards. All
electrical characteristics are checked after the test.
Recommended voltage:
≤
1250 VDC
C > 1 µF
0.1%
0.8%
–
p
d
std l
b
max l
30
30
30
30
30
b
±0.4
±0.4
±0.4
±0.4
±0.7
10.0 ± 0.4
0.6
17
15.0 ± 0.4 0.6/0.8* 17
22.5 ± 0.4
0.8
6
27.5 ± 0.4
0.8
6
37.5 ± 0.5
1.0
6
* Size 7.5 x 14.5 x 18.0 and bigger, d = 0.8
mm.
Tolerance in lead length
< 30 mm
+0
mm
–1
30 mm
+5
–0
mm
insulation resistance
resonance frequency
test voltage between
terminals
in dc applications
EnViRonmEntaL tEst data
Endurance
EN/IEC 60384-14:2005
1.7 x U
R
VAC 50 Hz, once every hour
increased to 1000 VAC for 0.1 s,
1000 h at upper rated temperature
3 directions at 2 hour each,
10 – 55 Hz at 0.75 mm or 98 m/s
2
No visible damage, No open or short circuit
vibration
Bump
IEC 60068-2-6, Test Fc
IEC 60068-2-29, Test Eb 1000 bumps at 390 m/s
2
Upper and lower rated
temperature 5 cycles
No visible damage, No open or short circuit
No visible damage
change of temperature
IEC 60068–2–14
Test Na
active flammability
Passive flammability
humidity
EN/IEC 60384-14:2005
EN/IEC 60384-14:2005
IEC 60068-2-3, Test Ca +40°C and 90 – 95% R.H.
56 days
PhE850
aRtiCLE taBLE
capaci- Box max dimensions
max
tance code in mm
f
o
du/dt article code
µf
B
h
l
mhz v/µs
capaci- Box max dimensions
max
tance code in mm
f
o
du/dt article code
µf
B
h
l
mhz v/µs
lEad sPacinG 10 mm
0.0010
0.0012
0.0015
0.0018
0.0022
0.0027
0.0033
0.0039
0.0047
0.0056
0.0068
0.0068
A06
A06
A01
A01
A01
A02
A02
A03
A03
A04
A04
A05
4.0
4.0
4.0
4.0
4.0
4.5
4.5
5.0
5.0
6.0
6.0
9.5
8.0
8.0
9.0
9.0
9.0
10.5
10.5
11.0
11.0
12.0
12.0
7.5
13.0
13.0
13.0
13.0
13.0
13.0
13.0
13.0
13.0
13.0
13.0
13.0
50
45
43
40
36
34
31
29
26
23
20
21
100
100
100
100
100
100
100
100
100
100
100
100
PHE850EA4100MA06R17
PHE850EA4120MA06R17
PHE850EA4150MA01R17
PHE850EA4180MA01R17
PHE850EA4220MA01R17
PHE850EA4270MA02R17
PHE850EA4330MA02R17
PHE850EA4390MA03R17
PHE850EA4470MA03R17
PHE850EA4560MA04R17
PHE850EA4680MA04R17
PHE850EP4680MA05R17
0.033
0.039
0.047
0.056
0.068
0.082
0.10
0.12
0.15
0.18
0.22
D13
D13
D13
D17
D17
D15
D18
D18
D16
D20
D20
6.5
6.5
6.5
7.0
7.0
9.0
10.5
10.5
11.0
13.5
13.5
lEad sPacinG 22.5 mm
14.5
14.5
14.5
16.5
16.5
18.5
19.0
19.0
21.5
23.0
23.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
26.0
5.7
5.4
5.0
4.7
4.3
4.0
3.6
3.3
2.8
2.5
2.3
100
100
100
100
100
100
100
100
100
100
100
PHE850ED5330MD13R06L2
PHE850ED5390MD13R06L2
PHE850ED5470MD13R06L2
PHE850ED5560MD17R06L2
PHE850ED5680MD17R06L2
PHE850ED5820MD15R06L2
PHE850ED6100MD18R06L2
PHE850ED6120MD18R06L2
PHE850ED6150MD16R06L2
PHE850ED6180MD20R06L2
PHE850ED6220MD20R06L2
lEad sPacinG 27.5
mm
0.15
0.15
0.18
0.22
0.27
0.33
0.39
0.47
0.47
0.56
0.68
F11
F17
F11
F12
F03
F13
F14
F14
F19
F16
F16
10.5
21.0
10.5
11.5
13.5
14.5
17.5
17.5
27.5
21.0
21.0
20.5
12.5
20.5
22.5
23.0
24.5
28.0
28.0
16.0
30.0
30.0
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
2.4
2.4
2.2
2.1
1.9
1.7
1.6
1.4
1.5
1.3
1.2
100
100
100
100
100
100
100
100
100
100
100
PHE850EF6150MF11R06L2
PHE850ET6150MF17R06L2
PHE850EF6180MF11R06L2
PHE850EF6220MF12R06L2
PHE850EF6270MF03R06L2
PHE850EF6330MF13R06L2
PHE850EF6390MF14R06L2
PHE850EF6470MF14R06L2
PHE850ET6470MF19R06L2
PHE850EF6560MF16R06L2
PHE850EZ6680MF16R06L2 *
lEad sPacinG 15 mm
0.0068
0.0082
0.010
0.012
0.015
0.018
0.022
0.027
0.033
0.039
0.047
0.047
0.056
0.068
B04
B04
B04
B05
B15
B10
B06
B06
B12
B11
B14
B17
B16
B16
5.5
5.5
5.5
5.5
6.0
6.5
7.5
7.5
8.0
8.5
9.5
13.0
11.0
11.0
10.5
10.5
10.5
12.5
12.0
12.5
14.5
14.5
15.0
16.0
17.5
12.5
19.0
19.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
14
14
13
12
11
10
9.5
8.6
7.8
7.0
6.3
6.3
5.5
4.7
100
100
100
100
100
100
100
100
100
100
100
100
100
100
PHE850EB4680MB04R17
PHE850EB4820MB04R17
PHE850EB5100MB04R17
PHE850EB5120MB05R17
PHE850EB5150MB15R17
PHE850EB5180MB10R17
PHE850EB5220MB06R17
PHE850EB5270MB06R17
PHE850EB5330MB12R17
PHE850EB5390MB11R17
PHE850EB5470MB14R17
PHE850EH5470MB17R17
PHE850EB5560MB16R17
PHE850EB5680MB16R17
lEad sPacinG 37.5 mm
0.33
R05 13.0 24.0
0.39
R05 13.0 24.0
0.47
R05 13.0 24.0
0.56
R04 15.0 26.0
0.68
R02 16.5 32.0
0.82
R02 16.5 32.0
1.0
R03 19.0 36.0
1.2
R06 21.0 38.0
1.5
R06 21.0 38.0
1.8
R08 28.0 43.0
2.2
R08 28.0 43.0
* Only ± 20% tolerance
41.0
41.0
41.0
41.0
41.0
41.0
41.0
41.0
41.0
41.0
41.0
1.2
1.1
1.1
1.0
0.94
0.88
0.81
0.74
0.66
0.58
0.54
100
100
100
100
100
100
100
100
100
100
100
PHE850ER6330MR05R06L2
PHE850ER6390MR05R06L2
PHE850ER6470MR05R06L2
PHE850ER6560MR04R06L2
PHE850ER6680MR02R06L2
PHE850ER6820MR02R06L2
PHE850ER7100MR03R06L2
PHE850ER7120MR06R06L2
PHE850EW7150MR06R06L2 *
PHE850ER7180MR08R06L2
PHE850ER7220MR08R06L2
appRoVaLs
certification Body specification
ENEC
UL
•
•
•
•
•
•
•
•
•
•
maRKing
RIFA
RIFA article code
Rated capacitance
Capacitance tolerance code
Rated voltage
Y2
Approval marks
IEC Climatic category
Passive flammability class
Manufacturing date code
EN/IEC 60384-14:2013
UL 60384-14
CAN/CSA-E60384-14:09
oRdERing inFoRmation
The article code for the standard part is given in the article table.
Statements of suitability for certain applications are based on our knowledge of typical operating conditions for such applications, but are not intended to constitute –
and we specifically disclaim – any warranty concerning suitability for a specific customer application or use. This Information is intended for use only by customers who
have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise
provided by us with reference to the use of our products is given gratis, and we assume no obligation or liability for the advice given or results obtained.