Parameter NameAttribute value
Is it Rohs certified?conform to
MakerTE Connectivity
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Factory Lead Time19 weeks
body width34.5 mm
body height30.7 mm
Body length or diameter52.3 mm
Maximum coil current (DC)0.035 A
Coil operating voltage (DC)36 V
Coil power1700 mW
Coil release voltage (DC)4.8 V
Coil resistance1390 Ω
Maximum coil voltage (DC)48 V
Coil/Input Power TypeDC
Contact (AC) maximum rated R load30A@277VAC
Maximum contact current (AC)30 A
Maximum contact current (DC)30 A
Contact (DC) maximum rated R load30A@28VDC
Maximum contact voltage (AC)277 V
Maximum contact voltage (DC)28 V
Contact/Output Power TypeAC/DC
Electrical life100000 Cycle(s)
Installation featuresTHROUGH HOLE-STRAIGHT MOUNT
operating hours25 ms
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
physical size52.3mm x 34.5mm x 30.7mm
GuidelineCSA; UL; VDE
Relay actionMOMENTARY
Relay functionDPST
Relay typePOWER/SIGNAL RELAY
release time25 ms
sealIMMERSION CLEANABLE CASE
surface mountNO
Termination typeSOLDER
General Purpose
High Power PCB Relays
Potter & Brumfield
T92 Series Two-pole 30A PCB or Panel Mount Relay
n
n
n
n
n
n
n
40A, 2 form A (NO) and 2 form C (CO) switching capability
Designed to control compressor loads to 3.5 tons, 110LRA / 25.3FLA
Meets requirements of UL 508 and UL 873 spacings - 8mm through
air, 9.5mm over surface
Meets requirements of VDE 8mm spacing, 4kV dielectric coil-to-
contact
Meets requirements of UL Class F construction
UL approved for 600VAC switching (1.5HP)
New screw terminal version (consult factory for availability,
ratings)
Typical applications
HVAC, residential / commercial appliances, industrial controls.
Approvals
CO
30A NO / 3A NC, 400VAC
30x10
3
Contact ratings
1)
(continued)
ARI 780-86 Endurance Test (section 6.6):
HVAC Definite Purpose Contactor Standard
Normally Open Contacts
Single Phase/Two Pole (Both poles together switching a single load)
110 LRA, 25.3 FLA, 200K operations (DC Coil)
UL E22575 (Recognized and Listed); CSA LR48471; VDE 40019600
Technical data of approved types on request.
Contact Data
Contact arrangement
2 form A (NO), 2 form C (CO)
Rated voltage
277VAC
Max. switching voltage
600VAC
Rated current
30A NO; 3A NC
Limiting continuous current
40A NO; 3A NC
Limiting making current
40A NO; 3A NC
Limiting breaking current
40A NO; 3A NC
Contact material
AgSnOInO, AgCdO
Min. recommended contact load
500ma (NO)/ 100ma (NC), 12VAC
Frequency of operation, with load
360hr
Operate/release time max., including bounce
25/25ms
Initial contact resistance
< 100 mΩ at 6VDC 1A
Contact ratings
1)
Type
Load
UL508
AgCdO
NO
40A, 277VAC, resistive
NO
30A, 120/277VAC, resistive
NO
10A, 600VAC, general purpose
NO
1HP, 120VAC
NO
3HP, 240VAC
NO
1.5HP, 480 or 600VAC
NO
110LRA/25.3FLA, 240VAC (DC coil only)
NO
60LRA/14FLA, 240VAC (AC coil only)
NO
3A, 240VAC, pilot duty
NO
20A, 28VDC, resistive
NO
TV10, 120VAC
NC
3A, 277VAC
NC
2A, 480VAC
NC
1A, 600VAC
AgSnOInO
NO
40A, 240VAC, resistive 85°C
NO
30A, 120/277VAC, resistive (DC coil only)
NO
30A, 120/277VAC, resistive (AC coil only)
NO
20A, 480VAC, resistive
NO
1.5HP, 120VAC, 2 pole making/breaking (Fig.1)
NO
3HP, 240VAC, 3 phase (DC coil only)
NO
3HP, 480VAC, 3 phase (DC coil only)
NO
2HP, 600VAC, 3 phase (DC coil only)
VDE
AgCdO, flange mount relays
NO
20A, 400VAC
NC
3A, 400VAC
CO
20A NO / 3A NC, 400VAC
AgCdO, PC mount relays
NO
30A, 400VAC
NC
3A, 400VAC
05-2017, Rev. 0517
www.te.com
© 2012 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
L1
Figure 1
L2
T2
T1
Single Phase Per Pole (Single load per pole)
110 LRA, 18 FLA, 200K operations (DC Coil).
60 LRA, 14 FLA, 200K operations (AC Coil).
L1
Figure 2
L2
T2
T1
Cycles
6x10
3
100x10
3
100x10
3
100x10
3
1x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
50x10
3
200x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
100x10
3
30x10
3
30x10
3
100x10
3
30x10
3
1) Contact ratings at 25°C (unless otherwise noted) with relay properly vented.
FLA, LRA ratings are compatible with 3.5 ton compressor applications.
Mechanical endurance
10x10
6
ops.
Coil Data
Coil voltage range
5 to 110VDC; 12 to 240VAC
Max. coil power
1.7W; 4.0VA
Max. coil temperature
155°C
Coil insulation system according UL
Class F
Coil versions, DC coil
Coil
Rated
Operate
Release
Coil
Rated coil
code
voltage
voltage
voltage
resistance
power
VDC
VDC
VDC
Ω±10%
W
6
6
4.5
0.6
22
1.7
9
9
6.75
0.9
48
1.7
12
12
9
1.2
86
1.7
18
18
13.5
1.8
197
1.7
24
24
18
2.4
350
1.7
48
48
36
4.8
1390
1.7
110
110
82.5
11
7255
1.7
Coil versions, AC coil
Coil
Rated Frequency Operate
Release
Coil
Rated coil
code voltage
voltage
voltage resistance power
VAC
Hz
VAC, 60Hz VAC, 60Hz Ω±10%
VA
12
12
60
9.6
1.2
9.1
4
24
24
60
19.2
2.4
36.6
4
120 110/120
50/60
96
12
950
4
240 220/240
50/60
192
24
3800
4
277 250/277
50/60
222
28
5485
4
Catalog and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Catalog product data, ‘Definitions’ section,
application notes and all specifications are
subject to change.
Catalog and product specification according
to IEC 61810-1 and to be used only together
with the ‘Definitions’ section.
1
The Linux Foundation expects revenue to reach $177 million this year
Source: https://www.cnbeta.com/articles/tech/1211839.htmThe Linux Foundation, known for hosting numerous open source projects and managing the Linux kernel, organizing countless events, and employing ...
dcexpert Talking
What does PAD mean in a circuit schematic?
There is no PAD pin in the chip manual. What is the purpose of adding this PAD and why should it be added? ? ? ?...
928083047 Analog electronics
September 23 nexperia live broadcast review: Nexperia's efficient ESD solutions for connected car applications
Live broadcast time: September 23, 14:00-15:30Live broadcast topic: Nexperia's efficient ESD solutions for connected car applicationsSpeech document: Click here to downloadWatch replay: Click to watch...
EEWORLD社区 Automotive Electronics
Knowledge of common op amp models
Common op amp model knowledgeCA3130 high input impedance operational amplifier Intersil [DATA] CA3140 High Input Impedance Operational Amplifier CD4573 Quad Programmable Operational Amplifier MC14573 ...
fish001 Analogue and Mixed Signal
These two methods make electric vehicles run farther in winter
As electric bicycles and electric motorcycles become more popular, consumers are demanding longer battery life. Extending the battery life of a battery pack allows the vehicle to travel further withou...
EEWORLD社区 TI Technology Forum
Voltage Follower
Because the sensor signal is relatively weak, direct amplification will cause signal distortion, so we use voltage following and then amplification. After following with LMV612, we found that the volt...
轩辕默殇 Analog electronics

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号