EEWORLDEEWORLDEEWORLD

Part Number

Search

0CBF010Z

Description
Circuit Breakers Clip Circuit 10A
CategoryCircuit protection   
File Size40KB,1 Pages
ManufacturerLittelfuse
Websitehttp://www.littelfuse.com
Download Datasheet Parametric View All

0CBF010Z Online Shopping

Suppliers Part Number Price MOQ In stock  
0CBF010Z - - View Buy Now

0CBF010Z Overview

Circuit Breakers Clip Circuit 10A

0CBF010Z Parametric

Parameter NameAttribute value
Product AttributeAttribute Value
ManufacturerLittelfuse
Product CategoryCircuit Breakers
RoHSN
ProductAftermarket Circuit Breakers
TypeFuse Clip
Current Rating10 A
Voltage Rating DC12 VDC
Number of Poles1 Pole
Actuator TypeSelf-Reset
IlluminatedNot Illuminated
PackagingBulk
Termination StyleQuick Connect
Voltage Rating12 VDC
Mounting StyleSnap In
Factory Pack Quantity1000
CIRCUIT BREAKERS
UCB
17
Universal Circuit Breakers
Universal Circuit Breakers function identically and have same internal components as
OEM breakers but offer the versatility of snap off terminals for greater flexibility. SAE
Type II modified reset used primarily as a wiring harness protector in 12 volt DC auto-
motive systems. Meets OEM requirements. Conforms to SAE J553C standard.
Designed to mount in ATO style fuse blocks and panels.
Bulk
Part No.
US
Carded No.
UCB 5 BP
UCB 10 BP
UCB 15 BP
Canadian
Carded No.
UCB 5 CABP
UCB 10 CABP
UCB 15 CABP
Amp
Rating
5
10
15
Bulk
Part No.
UCB 20
UCB 25
UCB 30
US
Carded No.
UCB 20 BP
UCB 25 BP
UCB 30 BP
Canadian
Carded No.
UCB 20 CABP
UCB 25 CABP
UCB 30 CABP
Amp
Rating
20
25
30
MRB
UCB 5
UCB 10
UCB 15
Manually Resettable Circuit Breakers
Manually Resettable Circuit Breakers feature an external button to allow resetting of the
device in a safe, convenient manner. SAE Type III manual reset used primarily as a
wiring harness protector in heavy duty 12 volt DC truck systems. Meets OEM require-
ments. Designed to mount in ATO style fuse blocks and panels.
Bulk
Part No.
Amp
Rating
10
15
20
25
30
Color
Red
Blue
Gold
Silver
Green
OEM #
Navistar
Navistar
Navistar
Navistar
Navistar
2011944C1
2011945C1
2011946C1
2011947C1
2011948C1
CIRCUIT
BREAKERS
MCB
MRB
MRB
MRB
MRB
MRB
10
15
20
25
30
MAXI
Circuit Breakers
Direct factory replacement for many domestic OEM applications. Designed to fit a
MAXI
Blade fuse block or panel. Available in either SAE Type I cycling or SAE Type II
non-cycling used primarily as a wiring harness protector in 12 volt DC automotive
systems. Meets OEM requirements. Conforms to SAE J553C standard.
Bulk
Part No.
US
Carded No.
Canadian
Carded No.
MCB 20 CABP
MCB 30 CABP
Amp
Rating
20
30
Typical Application
Automotive Headlamp
Automotive Headlamp,
Seats & Wipers
Automotive Power Devices
Heavy Truck & Auto
Cooling Fan
Automotive Power Window
Heavy Truck & Auto Cooling
Fan & Power Window
Heavy Truck
OEM No.
GM# 12065132
GM# 12088553
MXB
Cycling Design – Type I
MCB 20
MCB 20 BP
MCB 30
MCB 30 BP
Non-Cycling Design – Type II
MXB 20
MXB 20 BP
MXB 20 CABP
20
GM# 12077842
Ford# F6HT-14526-KA
GM# 12077843
Ford# F6HT-14526-LA
Ford# F6HT-14526-JA
MXB 30
MXB 30 BP
MXB 30 CABP
30
CBF
MXB 40
MXB 40 BP
MXB 40 CABP
40
Fuse Clip Circuit Breakers
Direct replacement for many OEM applications. Designed for glass fuses without
physical alteration in the system. Fits 1
1
/
4
" fuse clips. SAE Type II non-cycling used
primarily as a wiring harness protector in 12 volt DC automotive systems. Conforms to
SAE J553C standard.
Bulk
Part No.
CBF
CBF
CBF
CBF
10
15
20
25
US
Carded No.
CBF 10 BP
CBF 15 BP
CBF 20 BP
CBF 25 BP
Canadian
Carded No.
CBF 10 CABP
CBF 15 CABP
CBF 20 CABP
CBF 25 CABP
Amp
Rating
10
15
20
25
Bulk
Part No.
CBF 30
CBF 35
CBF 40
US
Carded No.
CBF 30 BP
CBF 35 BP
CBF 40 BP
Canadian
Carded No.
CBF 30 CABP
CBF 35 CABP
CBF 40 CABP
Amp
Rating
30
35
40
813
Stud Type Low Voltage (6–12 Volts) Circuit Breakers
SAE Type I automatic reset provides protection in installations where it is not possible to
manually reset a breaker because of location or safety requirements. Used primarily as
a wiring harness protector in 12 volt DC automotive systems. Conforms to SAE J553C
standard. Available with mounting bracket-change part number from 812 to 813, e.g.
813005 ST.
Bulk
Part No.
812005 ST
812006 ST
812008 ST
812010 ST
812015 ST
812020 ST
US
Carded No.
N/A
N/A
N/A
N/A
N/A
812020 BP
Canadian
Carded No.
N/A
N/A
N/A
N/A
N/A
812020 CABP
Amp
Rating
5
6
8
10
15
20
Bulk
Part No.
812025 ST
812030 ST
812035 ST
812040 ST
812050 ST
US
Carded No.
N/A
812030 BP
N/A
812040 BP
812050 BP
Canadian
Carded No.
N/A
812030 CABP
N/A
812040 CABP
812050 CABP
AL
812
Amp
Rating
25
30
35
40
50
E
QUI
E
PM
O
R
I
GI
N
Visit our web site at www.littelfuse.com
OEM
SU
P
PLIER
NT
NeoPixel Array Simulator
Use a computer to simulate the display effect of NeoPixel. You can simulate any NeoPixel color light array, up to a size of 40 x 35.[list] [*][url=https://www.hackster.io/gatoninja236/neopixel-matrix-...
dcexpert MicroPython Open Source section
【Power amplifier application】 Lamb wave signal analysis based on dry-coupled ultrasonic testing
The dry coupling ultrasonic testing method does not require the application of liquid coupling agents such as water or oil on the surface of the material to be tested. It is easy to operate and flexib...
aigtek01 Download Centre
Answer the questions and get a gift | Rochester Electronics will help you solve the problems of the entire semiconductor cycle
Event details: Rochester Electronics | Semiconductor full-cycle solution providerElectronic components are an important part of the electronic information industry. As we all know, semiconductor compo...
EEWORLD社区 Integrated technical exchanges
C language (vd6.0) sleep function usage and delay usage
1. Function name: delayFunction: Pause the execution of the program for a period of time (milliseconds)Usage: void delay(unsigned milliseconds);Program example:/* Emits a 440-Hz tone for 500 milliseco...
fish001 DSP and ARM Processors
Battery applications in medical monitoring and the changing environment
[size=4] As healthcare expands to include emerging technologies, as batteries shrink and connectivity increases, the medical field is poised for a paradigm shift in treatment options. In the next deca...
qwqwqw2088 Analogue and Mixed Signal
Extract LEF
When extracting .LEF files, select Abstract generate from the layout interface, extract the abstract view first, and then output the LEF through CIW, export, LEF OUT interface. Can it be used directly...
wanggy123 Analog electronics

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号