General-purpose Relay
G2R-@-S (S)
CSM_G2R-_-S_(S)_DS_E_1_2
Slim and Space-saving Power Plug-in Relay
■
Reduces wiring work by 60% when combined with the
P2RF-@-PU Push-In Plus Socket
(according to actual OMRON measurements).
■
Lockable test button models available.
■
Built-in mechanical operation indicator.
■
Provided with nameplate.
■
AC type is equipped with a coil-disconnection self-diagnostic
function (LED type).
■
High switching power (1-pole: 10 A).
LR
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Model Number Structure
Model Number Legend
G2R -
-S
(S)
4. Rated Coil Voltage
5. Mechanical operation indicator and Nameplate
(S):
Models with mechanical operation indicator and Nameplate
1
2
3
4
5
1. Number of Poles
1:
1 pole
2:
2 poles
2. Terminals
S:
Plug-in
3. Classification
Blank: General-purpose
N:
LED indicator
D:
Diode
ND: LED indicator and diode
NI:
LED indicator with test button
NDI: LED indicator and diode with test button
Note:
Contact your OMRON representative for Relays with gold-plated contacts.
Ordering Information
List of Models
Classification
General-purpose
LED indicator
LED indicator with test button
Diode
LED indicator and diode
LED indicator and diode with test button
When your order, specify the rated voltage.
Coil ratings
AC 24, 110, 120, 230, 240
DC 6, 12, 24, 48
Contact form
SPDT
G2R-1-S (S)
G2R-1-SN (S)
G2R-1-SNI (S)
G2R-1-SD (S)
G2R-1-SND (S)
G2R-1-SNDI (S)
DPDT
G2R-2-S (S)
G2R-2-SN (S)
G2R-2-SNI (S)
G2R-2-SD (S)
G2R-2-SND (S)
G2R-2-SNDI (S)
DC 6, 12, 24, 48
Note: 1.
The standard models are compliant with UL/CSA and VDE standards. Also, an EC compliance declaration has been made for combina-
tions with the P2RF-@-E, P2RF-@-S and P2RF-@-PU. The Relays bear the CE Marking.
2.
Refer to
Connecting Sockets,
below, for applicable Socket models.
3.
When ordering, add the rated coil voltage and "(S)" to the model number. Rated coil voltages are given in the coil ratings table.
Example: G2R-1-S 12 VDC (S)
Rated coil voltage
1
G2R-@-S (S)
Accessories (Order Separately)
Connecting Sockets
Track/surface-mounting Socket
Applicable Relay model
No. of poles
1 pole
2 poles
G2R-1-S (S)
G2R-2-S (S)
Push-In Plus
Terminal Blocks
Model
P2RF-05-PU
P2RF-08-PU
Screw terminals *
Models
P2RF-05
P2RF-05-E
P2RF-08
P2RF-08-E
Back-mounting Socket
PCB terminals
Models
P2R-05P
P2R-057P
P2R-08P
P2R-087P
P2R-05A
P2R-08A
Solder terminals
Model
* The structure of P2RF-@-E models provides finger protection. Round terminals cannot be used. Use forked crimp terminals.
Accessories for Push-In Plus Terminal Block Sockets (P2RF-@-PU)
Short Bars
Pitch
No. of poles
2
7.75 mm
3
4
20
15.5 mm
8
Red (R)
Blue (S)
Yellow (Y)
Colors
Model
*
PYDN-7.75-020@
PYDN-7.75-030@
PYDN-7.75-040@
PYDN-7.75-200@
PYDN-15.5-080@
10
Minimum order (quantity)
Note:
Use the Short Bars for crossover wiring within one Socket or between Sockets.
* Replace the box (@) in the model number with the code for the covering color.
Labels
Model
XW5Z-P4.0LB1
Minimum order (sheet)
(quantity per sheet)
5
1 sheet (60 pieces)
Mounting Tracks
Applicable Socket
Mounting track
Track-connecting Socket
End plate *1
Spacer
Back-connecting Socket Mounting plate *2
Description
1 m (l) × 7.3 mm (t):
1 m (l) × 16 mm (t):
Model
PFP-100N
PFP-100N2
PFP-M
PFP-S
P2R-P
10
1
Minimum order
(quantity)
---
50 cm (l) × 7.3 mm (t):
PFP-50N
*1. When mounting DIN rail, please use End Plate (PFP-M).
*2. Used to mount several P2R-05A and P2R-08A Connecting Sockets side by side.
2
G2R-@-S (S)
Specifications
Coil Ratings
Rated current*
Rated voltage
50 Hz
24 V
110 V
AC
120 V
230 V
240 V
43.5 mA
9.5 mA
8.6 mA
4.4 mA
3.7 mA
60 Hz
37.4 mA
8.2 mA
7.5 mA
3.8 mA
3.2 mA
253
Ω
5,566
Ω
7,286
Ω
27,172
Ω
30,360
Ω
Coil
resistance
Coil inductance (H)
(ref. value)
Armature
OFF
0.81
13.33
16.13
72.68
90.58
Armature
ON
1.55
26.83
32.46
143.90
182.34
Must
operate
voltage
Must
release
voltage
Max.
voltage
80% max.
30% max.
110%
0.9 VA at 60 Hz
Must
operate
voltage
Must
release
voltage
Max.
voltage
Power
consumption
(approx.)
% of rated voltage
Rated voltage
Rated current*
Coil
resistance
69
Ω
278
Ω
1,113
Ω
4,220
Ω
Coil inductance (H)
(ref. value)
Armature
OFF
0.25
0.98
3.60
15.2
Armature
ON
0.48
2.35
8.25
29.82
% of rated voltage
Power
consumption
(approx.)
6V
DC
12 V
24 V
48 V
87.0 mA
43.2 mA
21.6 mA
11.4 mA
70% max.
15% min.
110%
0.53 W
Note: 1.
The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/-20% for the AC rated current
and ±10% for the DC coil resistance.
2.
The AC coil resistance and inductance values are reference values only (at 60 Hz).
3.
Operating characteristics were measured at a coil temperature of 23°C.
4.
The maximum voltage is the maximum possible value of the voltage that can be applied to the relay coil.
It is not the maximum voltage that can be applied continuously.
Contact Ratings
Number of poles
Load
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
Failure rate (reference value) *
1 pole
Resistive load
(cosφ = 1)
10 A at 250 VAC;
10 A at 30 VDC
10 A
440 VAC, 125 VDC
10 A
2,500 VA,
300 W
100 mA at 5 VDC
1,875 VA,
150 W
Inductive load
(cosφ = 0.4; L/R = 7 ms)
7.5 A at 250 VAC;
5 A at 30 VDC
2 poles
Resistive load
(cosφ = 1)
5 A at 250 VAC;
5 A at 30 VDC
5A
380 VAC, 125 VDC
5A
1,250 VA,
150 W
10 mA at 5 VDC
500 VA,
90 W
Inductive load
(cosφ = 0.4; L/R = 7 ms)
2 A at 250 VAC; 3 A at
30 VDC
Note:
P level:
λ
60
= 0.1 x 10
-6
/operation
* This value was measured at a switching frequency of 120 operations per minute.
3
G2R-@-S (S)
Characteristics
Item
Contact configration
Contact structure
Contact resistance
Operate (set) time
Release (reset) time
Max. operating
frequency
Insulation resistance
Dielectric strength *
SPDT
Single
100 mΩ max.
15 ms max.
AC: 10 ms max.; DC: 5 ms max.
(w/built-in diode: 20 ms max.)
Mechanical:
Electrical:
AC: 15 ms max.; DC: 10 ms max.
(w/built-in diode: 20 ms max.)
1 pole
2 poles
18,000 operations/hr
1,800 operations/hr (under rated load)
1,000 MΩ min. (at 500 VDC)
5,000 VAC, 50/60 Hz for 1 min between coil and
5,000 VAC, 50/60 Hz for 1 min between coil and contacts;
contacts;
3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
same polarity
Destruction:
Malfunction:
Destruction:
Malfunction:
Mechanical:
Electrical:
Operating:
Operating:
Approx. 20 g
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
1,000 m/s
2
200 m/s
2
when energized; 100 m/s
2
when not energized
AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
100,000 operations min. (at 1,800 operations/hr under rated load)
–40°C to 70°C (with no icing or condensation)
5% to 85%
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
Note:
Values in the above table are the initial values.
* These values are relay only. Prease refer to the “Products Related to Common Sockets and DIN Tracks Data Sheet” for connecting sockets.
Approved Standards
UL 508 (File No. E41643)
Model
Contact
Coil ratings
form
Contact ratings
Opera-
tions
10 A, 30 VDC (resistive)
100 × 10
3
10 A, 250 VAC (general use)
25 × 10
3
5 to 110 VDC TV-3 (NO contact only)
6 to 240 VAC 5 A, 30 VDC (resistive)
100 × 10
3
5 A, 250 VAC (general use)
TV-3 (NO contact only)
25 × 10
3
IEC/VDE (Certificate No. 40015012 EN 61810-1)
Contact
form
1 pole
Coil ratings
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
Contact ratings
5 A, 440 VAC (cosφ = 1.0)
10 A, 250 VAC (cosφ = 1.0)
10 A, 30 VDC (0 ms)
5 A, 250 VAC (cosφ =1.0)
5 A, 30 VDC (0 ms)
Operations
100 × 10
3
G2R-1-S (S) SPDT
G2R-2-S (S) DPDT
2 poles
100 × 10
3
CSA 22.2 No.0, No.14
(File No. LR31928)
Model
Contact
Coil ratings
form
Contact ratings
Opera-
tions
10 A, 30 VDC (resistive)
100 × 10
3
10 A, 250 VAC (general use)
25 × 10
3
5 to 110 VDC TV-3 (NO contact only)
6 to 240 VAC 5 A, 30 VDC (resistive)
100 × 10
3
5 A, 250 VAC (general use)
TV-3 (NO contact only)
25 × 10
3
LR
Number
of poles
1 pole
Coil ratings
5 to 110 VDC
6 to 240 VDC
Contact ratings
10 A, 250 VAC (general use)
7.5 A, 250 VAC (PF0.4)
10 A, 30 VDC (resistive)
5A, 30VDC (L/R=7ms)
5 A, 250 VAC (general use)
2 A, 250 VAC (PF0.4)
5 A, 30 VDC (resistive)
3A, 30VDC (L/R=7ms)
Operations
100 × 10
3
G2R-1-S (S) SPDT
2 poles
5 to 110 VDC
6 to 240 VDC
100 × 10
3
G2R-2-S (S) DPDT
4
G2R-@-S (S)
Engineering Data
Maximum Switching Power
G2R-1-S (S)
100
G2R-2-S (S)
100
Switching current (A)
Switching current (A)
AC inductive load
(cosφ = 0.4)
AC resistive
load
10
DC resistive
load
DC inductive load
(L/R = 7 ms)
10
AC inductive load
(cosφ = 0.4)
AC resistive
load
DC resistive
load
1
1
DC inductive load
(L/R = 7 ms)
0.1
1
10
100
1000
0.1
1
10
100
1000
Switching voltage (V)
Switching voltage (V)
Endurance
G2R-1-S (S)
Endurance (x10
3
operations)
5,000
G2R-2-S (S)
10,000
Endurance (x10
3
operations)
5,000
1,000
500
250-VAC/30-VDC
resistive load
250-VAC inductive load
(cosφ = 0.4)
1,000
500
30-VDC inductive load (L/R = 7ms)
250-VAC/30-VDC
resistive load
100
50
30-VDC inductive load (L/R = 7ms)
100
250-VAC
50
inductive load
(cosφ = 0.4)
Switching current (A)
Switching current (A)
Ambient Temperature vs Maximum Coil Voltage
Maximum voltage (%)
DC coil
AC coil
Ambient temperature (°C)
5