economical solution to the challenge of load-applied
harmonics mitigation in three-phase power systems.
With a plug-and-play approach and more compact
dimensions than comparable products, they can be
quickly installed and easily commissioned. They
increase the reliability and service life of electric
installations, help utilize electric sytem capacity
better, and are the key to meet Power Quality
standards such as IEEE 519. Ecosine filters reshape
your distorted current back to the desired sinusoidal
waveform. Schaffner ecosine filters can be applied to
virtually any kind of power electronics with front-end
six-pulse rectifiers, 3-phase diode or thyristor bridges,
where harmonic current distortion needs to be
reduced to defined limits.
Technical specifications
Nominal operating voltage
Operating frequency
Nominal motor drive input power rating
Total harmonic current distortion THID*
Efficiency
High potential test voltage
Protection category
Cooling
Overload capability
Ambient temperature range
3 x 440 VAC to 500 VAC ±10%
50 Hz ±1 Hz
1.1 to 250 kW
≤5% at rated power
>98% for rated voltage and power
P –> E 2160 VAC (1 s)
IP 00, IP 20
Internal fan cooling or external cooling**
1.6x rated current for 1 minute, once per hour
–25°C to +45°C fully operational
–25°C to +85°C transport and storage
+45°C to +70°C derated operation***
UL 94 V-2
Filter: UL 61800-5-1, EN 61800-5-1
Chokes: EN 61558-2-20 or EN 60076-6
>200,000 hours
100 kA
TN, TT, IT
OV III (IEC 60664-1 / UL 61800-5-1)
Typical applications
Equipment with front-end six-pulse rectifier
Motor drives
Factory automation equipment
Water/wastewater treatment facilities
Fan and pump applications
HVAC installations
Mission-critical processes
DC fast chargers
Flammability corresponding to
Design corresponding to
MTBF @ 45°C/415 V (Mil-HB-217F)
SCCR****
Earthing System
Overvoltage category
Typical electrical schematic
****System requirements: THVD <2%, line voltage unbalance <1%
** *
Note: performance specifications in this brochure refer to six-pulse diode rectifiers with 8% DC-link choke.
THID ~5% at rated power for filter <6 kW
** Please check the inlet air flow required for cooling table on page 6 of this document.
*** I
derated
= I
nominal
*√((T
max-
T
amb
)/(T
max-
T
nominal
)) = I
nom
*√(70°C-T
amb
)/25°C
**** External UL-rated fuses required. Please consult the user manual.
(all configurable optional fuctionalities shown)
2
Ecosine passive
Schaffner Group
Datasheets
15 Nov 2018
Filter selection table – IP 00 enclosure
Filter
Rated load power
@ 480 VAC/50 Hz
[kW]
FN 3451-1-110-E0_ _ _ _ _*
FN 3451-2-110-E0_ _ _ _ _*
FN 3451-4-112-E0_ _ _ _ _*
FN 3451-6-112-E0_ _ _ _ _*
FN 3451-8-112-E0_ _ _ _ _*
FN 3451-11-112-E0_ _ _ _ _*
FN 3451-15-113-E0_ _ _ _ _
FN 3451-19-113-E0_ _ _ _ _
FN 3451-22-113-E0_ _ _ _ _
FN 3451-30-115-E0_ _ _ _ _
FN 3451-37-115-E0_ _ _ _ _
FN 3451-45-115-E0_ _ _ _ _
FN 3451-55-115-E0_ _ _ _ _
FN 3451-75-115-E0_ _ _ _ _
FN 3451-90-116-E0_ _ _ _ _
FN 3451-110-116-E0_ _ _ _ _
FN 3451-132-118-E0_ _ _ _ _
FN 3451-160-118-E0_ _ _ _ _**
FN 3451-200-118-E0_ _ _ _ _**
FN 3451-250-118-E0_ _ _ _ _**
1.1
2.2
4
5.5
7.5
11
15
19
22
30
37
45
55
75
90
110
132
160
200
250
Motor drive
input current***
[Arms]
1.4
2.8
5.1
7.1
9.6
14.1
19.3
24.4
28
38.5
47.5
58
71
97
116
142
170
207
259
324
Rated filter
input current
[Arms]
1.3
2.7
4.9
6.7
9.2
13.4
18.3
23
27
36.6
45
55
67
92
110
135
162
197
246
308
Min. required
L
DC
****
[mH]
53.87
26.94
14.82
10.78
7.90
5.39
3.95
3.12
2.69
1.98
1.60
1.32
1.08
0.79
0.66
0.54
0.45
0.37
0.30
0.24
Min. required
L
AC
****
[mH]
16.70
7.85
4.47
3.48
2.55
1.82
1.26
1.02
0.88
0.64
0.527
0.451
0.357
0.265
0.218
0.176
0.149
0.118
0.094
0.073
[kg]
5
7
10
12
15
17
24
27
31
38
43
49
54
70
100
108
130
149
183
221
110
110
112
112
112
112
113
113
113
115
115
115
115
115
116
116
118
118
118
118
A
A
B
B
C
C
D
D
D
E
E
E
F
F
G
G
H
H
H
H
Weight
Terminal
Frame size
*
Filter rating which does not require forced cooling or fan module
** Filter rating which does not require RC damping module for rectifiers with EMI filter
*** Motor drive input current without harmonic filter
**** In order to apply FN 3451 filters, motor drives have to be equipped with either DC-link choke or AC line choke. The minimum required inductance
values are given in mH in the filter selection table. If neither DC-link choke nor AC line choke is present, or if the minimum mH rating is not fulfilled,
FN 3451 filter must not be used. In this case, FN 3450 need to be chosen.
Filter power terminals
Terminal designation*
Screw thread
Flex wire AWG
Flex wire
Screw torque value
Max width**
cable lug
[mm
2
]
110
112
113
115
116
118
M3
M4
M6
M8
M8
M10
14-22
10-22
6-18
1/0-8
3/0-8
3/0-500 kcmil
0.4-2.5
0.4-6
0.75-16
10-50
10-95
95-240
[Nm]
0.5
1.2
3
8
8
10
[lbs·in]
4.4
10.6
26.6
70.8
70.8
88.5
[mm]
7
10
15
15
17
35
A
B, C
D
E, F
G
H
Frame size
* Recommended connector type: wire or cable lug for 110 to 113, only cable lug for 115 to 118
** To fulfill creepage/clearance acc. UL 61800-5-1 without additional protection (insulation). Creepage/clearance can vary depending on applicable standard and must
be reviewed by customer. Creepage/clearance may be reduced when additional protection (insulation) is provided.
Filter signal and earth terminals
Terminal type
Screw thread
Screw torque value
[Nm]
Signal
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
M3*
M5
M6
M6
M8
M8
M10
M10
M10
0.5
4
8
8
14
14
25
25
25
All
A
B
C
D
E
F
G
H
Frame size
* Max width cable lug = 7 mm
3
Ecosine passive
Schaffner Group
Datasheets
15 Nov 2018
Filter selection table – IP 20 enclosure
Filter
Rated load power
@ 480 VAC/50 Hz
[kW]
FN 3451-1-110-E2_ _ _ _ _*
FN 3451-2-110-E2_ _ _ _ _*
FN 3451-4-112-E2_ _ _ _ _*
FN 3451-6-112-E2_ _ _ _ _*
FN 3451-8-112-E2_ _ _ _ _*
FN 3451-11-112-E2_ _ _ _ _*
FN 3451-15-113-E2_ _ _ _ _
FN 3451-19-113-E2_ _ _ _ _
FN 3451-22-113-E2_ _ _ _ _
FN 3451-30-115-E2_ _ _ _ _
FN 3451-37-115-E2_ _ _ _ _
FN 3451-45-115-E2_ _ _ _ _
FN 3451-55-115-E2_ _ _ _ _
FN 3451-75-115-E2_ _ _ _ _
FN 3451-90-116-E2_ _ _ _ _
FN 3451-110-116-E2_ _ _ _ _
FN 3451-132-118-E2_ _ _ _ _
FN 3451-160-118-E2_ _ _ _ _**
FN 3451-200-118-E2_ _ _ _ _**
FN 3451-250-118-E2_ _ _ _ _**
1.1
2.2
4
5.5
7.5
11
15
19
22
30
37
45
55
75
90
110
132
160
200
250
Motor drive
input current***
[Arms]
1.4
2.8
5.1
7.1
9.6
14.1
19.3
24.4
28
38.5
47.5
58
71
97
116
142
170
207
259
324
Rated filter
input current
[Arms]
1.3
2.7
4.9
6.7
9.2
13.4
18.3
23
27
36.6
45
55
67
92
110
135
162
197
246
308
Min. required
L
DC
****
[mH]
53.87
26.94
14.82
10.78
7.90
5.39
3.95
3.12
2.69
1.98
1.60
1.32
1.08
0.79
0.66
0.54
0.45
0.37
0.30
0.24
Min. required
L
AC
****
[mH]
16.70
7.85
4.47
3.48
2.55
1.82
1.26
1.02
0.88
0.64
0.527
0.451
0.357
0.265
0.218
0.176
0.149
0.118
0.094
0.073
[kg]
6
8
11
13
16
19
28
30
34
44
49
55
62
77
109
117
147
166
200
238
110
110
112
112
112
112
113
113
113
115
115
115
115
115
116
116
118
118
118
118
A
A
B
B
C
C
D
D
D
E
E
E
F
F
G
G
H
H
H
H
Weight
Terminal
Frame size
*
Filter rating which does not require forced cooling or fan module
** Filter rating which does not require RC damping module for rectifiers with EMI filter
*** Motor drive input current without harmonic filter
**** In order to apply FN 3451 filters, motor drives have to be equipped with either DC-link choke or AC line choke. The minimum required inductance
values are given in mH in the filter selection table. If neither DC-link choke nor AC line choke is present, or if the minimum mH rating is not fulfilled,
FN 3451 filter must not be used. In this case, FN 3450 need to be chosen.
Filter power terminals
Terminal designation*
Screw thread
Flex wire AWG
Flex wire
Screw torque value
Max width**
cable lug
[mm
2
]
110
112
113
115
116
118
M3
M4
M6
M8
M8
M10
14-22
10-22
6-18
1/0-8
3/0-8
3/0-500 kcmil
0.4-2.5
0.4-6
0.75-16
10-50
10-95
95-240
[Nm]
0.5
1.2
3
8
8
10
[mm]
7
10
15
15
17
35
A
B, C
D
E, F
G
H
Frame size
* Recommended connector type: wire or cable lug for 110 to 113, only cable lug for 115 to 118
** To fulfill creepage/clearance acc. UL 61800-5-1 without additional protection (insulation). Creepage/clearance can vary depending on applicable standard and must
be reviewed by customer. Creepage/clearance may be reduced when additional protection (insulation) is provided.
Filter signal and earth terminals
Terminal type
Screw thread
Screw torque value
[Nm]
Signal
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
M3*
M5
M6
M6
M8
M8
M10
M10
M10
0.5
4
8
8
14
14
25
25
25
All
A
B
C
D
E
F
G
H
Frame size
* Max width cable lug = 7 mm
4
Ecosine passive
Schaffner Group
Datasheets
15 Nov 2018
Product selector
Table 1: Filter configurations if external air flow is available for cooling
(Filters do
not contain fan
and do
not contain aux. power supply)
E0XXXXX
- For rectifiers with DC-link choke
E0XXJXX
- For rectifiers with DC-link choke
- Filters contain trap disconnect
jumper
E0XXXRX
- For rectifiers with DC-link choke
and with EMI filter
- Filters contain RC damper
module
E0XXJRX
- For rectifiers with DC-link choke
and with EMI filter
- Filters contain RC damper
module and trap disconnect
jumper
5
Ecosine passive
Schaffner Group
Datasheets
15 Nov 2018
Table 2: Filter configurations with embedded ventilation
(Filters
contain fan
and
aux. power supply)
E0FAXXX and E2FAXXX
- For rectifiers with DC-link choke
- Filters contain fan and aux. power
supply
E0FAJXX and E2FAJXX
- For rectifiers with DC-link choke
- Filters contain fan, aux. power
supply and trap disconnect
jumper
E0FAXRX and E2FAXRX
- For rectifiers with DC-link choke
and with EMI filter
- Filters contain fan, aux. power
supply and RC damper module
E0FAJRX and E2FAJRX
- For rectifiers with DC-link choke
and with EMI filter
- Filters contain fan, aux. power
supply, RC damper module and
trap disconnect jumper
Table 3: Filter configurations if external aux. power supply for the fan is available
In our work, we often use the unit "dB". For example, insertion loss, return loss, power, we often use xx dB, or xx dBm to describe. Of course, for colleagues, it is easy to understand what you mean, ...
Introduction to Switching Power Supply Circuit Design : https://training.eeworld.com.cn/course/5424Hardware Trio Switching Power Supply Circuit Design Getting Started Video Tutorial...
An aquarium automation system using the Feather nRF52840 and four additional FeatherWings. There is an automatic fish feeder and a Raspbery Pi based Fishpi display for monitoring temperature and light...
[i=s]This post was last edited by bigbat on 2019-2-23 12:35[/i] The network part is successful using the built-in routines! The NUCLEO-H743ZI development board for testing is provided by ST. For detai...
Please advise, the simulation or burning of soc_blinky or soc_empty project fails. I have tried many methods, but it doesn't work. Does anyone know the reason?...
Preface
With the popularity of mobile phones, portable music players and portable game consoles, people have begun to demand that these electronic devices be designed to be more compact, h...[Details]
Pulse Width Modulation (PWM) is a very effective technology that uses the digital output of a microprocessor to control analog circuits. It is widely used in many fields from measurement, communicati...[Details]
Recently, a photo of the packaging box of vivo V17 Pro was exposed. The packaging box clearly shows the appearance of the phone, and it can be known that the packaging box is configured for the 8GB+1...[Details]
The default unit of the spectrum analyzer is dBm, which is the power level value; the default unit of the EMI receiver is dBμV, which is the voltage level. Why use different units of measurement? In ...[Details]
Regarding the selection points of insertion electromagnetic flowmeter, we must understand which parameters affect the use effect of insertion electromagnetic flowmeter in order to accurately select th...[Details]
DLP projection technology is a technology that uses the digital micromirror device (DMD) developed by Texas Instruments as the main key processing element to realize the digital optical processing pr...[Details]
"If you want to build a ship, don't encourage people to cut wood, assign work, or give orders. Instead, guide them to yearn for the vast ocean." Ziguang Guwei, which has gone through multiple strateg...[Details]
The structure, characteristics and applications of LED
50 years ago, people already knew the basic knowledge that semiconductor materials can generate light, and the first commercial diode was...[Details]
Abstract:
This article mainly introduces the application of Delta VL series inverters in the elevator industry, and describes in detail the mechanical structure, electrical control system archite...[Details]
Oscilloscope The oscilloscope, also known as a handheld oscilloscope, is easy to carry and easy to operate. It can transform invisible electrical signals into visible images, making it easier for peo...[Details]
Recently, a team of professional analysts from Beijing Huaxing Wanbang Management Consulting Co., Ltd. went to Nuremberg, Germany to attend the "Embedded World 2019" and exchanged ideas with many ...[Details]
In the power supply industry, oscilloscopes are universal test instruments, but many special requirements, such as power supply testing requires channel isolation, sometimes the number of channels ne...[Details]
Recently, Zoss Automotive Research conducted an exclusive interview with Xu Chao, Vice President of CoreDrive Technology, to discuss how CoreDrive will position itself and provide better products and...[Details]