Solid-state Relay
PCB-mounting SSR for FA Equipment
Requiring High Reliability
Wide I/O voltage range: 3 to 28 VDC input and 75 to
264 VAC output or 3 to 28 VDC input and 3 to
52.8 VDC output.
Two load currents available: 2 A and 3 A
Flat and vertical models available for a variety of
applications.
Approved by UL and CSA.
G3CN
RC
Ordering Information
Isolation
Photocoupler
Zero cross
function
Yes
Indicator
No
Rated output voltage
(Applicable output load)
2 A at 100 to 240 VAC
(2 A at 75 to 264 VAC)
3 A at 100 to 240 VAC
(3 A at 75 to 264 VAC)
Phototriac
No
2 A at 100 to 240 VAC
(2 A at 75 to 264 VAC)
3 A at 100 to 240 VAC
(3 A at 75 to 264 VAC)
Photocoupler
---
2 A at 4 to 48 VDC
(2 A at 3 to 52.8 VDC)
3 A at 4 to 48 VDC
(3 A at 3 to 52.8 VDC)
*Vertical models.
**When ordering, specify the input voltage
4 to 24 VDC
5, 12, 24 VDC**
Rated input voltage
4 to 24 VDC
Model
G3CN-202P-US
G3CN-202P1-US*
G3CN-203P-US
G3CN-203P1-US*
G3CN-202PL-US
G3CN-202PL1-US*
G3CN-203PL-US
G3CN-203PL1-US*
G3CN-DX02P-US
G3CN-DX02P1-US*
G3CN-DX03P-US
G3CN-DX03P1-US*
171
G3CN
G3CN
Specifications
Ratings
Input
Model
Rated voltage
Operating voltage
Impedance
Voltage level
Must operate
voltage
G3CN-202P(1)-US
G3CN-203P(1)-US
G3CN-202PL(1)-US
G3C
0
( ) US
G3CN 203PL(1) US
G3CN-203PL(1)-US
4 to 24 VDC
5 VDC
12 VDC
24 VDC
G3CN-DX02P(1)-US
G3CN-DX03P(1)-US
Note:
4 to 24 VDC
3 to 28 VDC
4 to 6 VDC
9.6 to 14.4 VDC
19.2 to 28.8 VDC
3 to 28 VDC
1.5 kΩ
+20%
/
–10%
390
Ω±20%
900
Ω±20%
2 kΩ±20%
1.5 kΩ
+20%
/
–10%
3 VDC max.
4 VDC max.
9.6 VDC max.
19.2 VDC max.
3 VDC max.
Must release
voltage
1 VDC min.
The input impedance is measured at the maximum value of the operating voltage. For example, with the model rated at 4 to 24 VDC, the
input impedance is measured at 28 VDC.
Output
Model
Rated load voltage
G3CN-202P(1)-US
G3CN-202PL(1)-US
G3CN-203P(1)-US
G3CN-203PL(1)-US
G3CN-DX02P(1)-US
G3CN-DX03P(1)-US
4 to 48 VDC
3 to 52.8 VDC
100 to 240 VAC
Applicable load
Load volage range
75 to 264 VAC
Load current
Without heat sink
0.1 to 2 A
0.1 to 3 A
0.1 to 2 A
0.1 to 3 A
30 A (60 Hz, 1 cycle)
45 A (60 Hz, 1 cycle)
12 A (10 ms)
18 A (10 ms)
Inrush current
Characteristics
Item
Operate time
Release time
Output ON voltage drop
Leakage current
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Approved standards
Weight
G3CN-202P(1)/203P(1)-US
1/2 of load power source cycle +
1 ms max.
1/2 of load power source cycle +
1 ms max.
1.6 V (RMS) max.
5 mA max. (at 100 VAC)
10 mA max. (at 200 VAC)
100 MΩ min. (at 500 VDC)
2,500 VAC, 50/60 Hz for 1 min
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Malfunction: 1,000 m/s
2
Operating: –30°C to 80°C (with no icing nor condensation)
Storage: –30°C to 100°C (with no icing nor condensation)
Operating: 45% to 85%
UL508, UL114 File No.E64562, CSA C22.2 (No.0, No.14) File No. LR35535
Approx. 25 g
2.5 mA max. (at 100 VAC)
5 mA max. (at 200 VAC)
G3CN-202PL(1)/203PL(1)-US
1 ms max.
1/2 of load power source cycle
+ 1 ms max.
G3CN-DX02P(1)/03P(1)-US
0.5 ms max.
2 ms max.
1.5 V max.
5 mA max. (at 50 VDC)
172
G3CN
G3CN
Engineering Data
Load Current vs. Ambient Temperature Characteristics
G3CN-202P(1)/-202PL(1)/-DX02P(1)-US
G3CN-203P(1)/-203PL(1)/-DX03P(1)-US
Load current (A)
Ambient temperature (°C)
Load current (A)
Ambient temperature (°C)
Inrush Current Resistivity
Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.)
G3CN-202P(1)/-202PL(1)-US
G3CN-DX02P(1)-US
Inrush current (A. Peak)
Energizing time (ms)
Inrush current (A. Peak)
Energizing time (ms)
G3CN-203P(1)/-203PL(1)-US
G3CN-DX03P(1)-US
Inrush current (A. Peak)
Energizing time (ms)
Inrush current (A. Peak)
Energizing time (ms)
173
G3CN
G3CN
Dimensions
Note:
All units are in millimeters unless otherwise indicated.
Flat Model
G3CN-20jP/-20jPL/-DX0jP
33 max.
25 max.
Terminal Arrangement/
Mounting Holes
(Bottom View)
Four 1.2-dia.
holes
25
Two, 4 dia.
holes
10
14.5
20 max. max.
1.5 max.
Two, 2-dia.
holes
0.4
25±0.5
0.7
10±0.5
12.5±0.5
+
Input
voltage
–
3
+
Input
–
4
Load
(–)
2
0.7
12.5
Terminal Arrangement/
Internal Connections
(Bottom View)
1
(+)
Load power
supply
(–)
Load
(+)
Vertical Model
G3CN-20jP1/-20jPL1/-DX0jP1
33 max.
Note:
Values in parentheses apply
to the DC-load versions.
14 max.
Terminal Arrangement/
Mounting Holes
(Bottom View)
Two, 2-dia.
holes
Four 1.2-dia.
holes
Pattern
5
26.5 max.
32 max.
1.5 max.
(17.5)
27.5
5
Pattern
Terminal Arrangement/
Internal Connections
(Bottom View)
(17.5)
27.5±0.5
0.7
5±0.5
0.4
3±1
Input voltage
–
+
Load power supply
(–)
(+)
Load
5±0.5
4
–
3
+
Input
(–)
2 1
(+)
Load
Note:
Values in parentheses apply
to the DC-load versions.
174
G3CN
G3CN
Precautions
Refer to pages 11 to 19 for general precautions.
Connection
With the SSR for DC switching, the load can be connected to either
positive or negative output terminal of the SSR.
Protective Component
Since the SSR does not incorporate an overvoltage absorption
component, be sure to connect an overvoltage absorption compo-
nent when using the SSR under an inductive load.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. K063-E1-2A