G6D
PCB Power Relay
Slim, Miniature Relay, Capable
of Relaying Programmable
Controller and Temperature
Controller Outputs
• Reduced board space, ideal for high-density mounting (45%.
(6.5 mm (W) × 17.5 mm (L) × 12.5 mm (H))
• Small, yet switches 5 A at 250 VAC/30 VDC.
• Allows 300,000 operations with a 2-A load at 250 VAC or
30 VDC.
RoHS Compliant
■Model
Number Legend
1 2 3 4
1. Number of Poles
1: 1-pole
2. Contact Form
A: SPST-NO (1a)
■Application
Examples
• Ideal for output applications of control
equipments.
G6D-
@ @- @- @
—— — —
3. Contact Material
ASI: Silver alloy
(cadmium-free)
4. Contact surface
AP: Au plated
■Characteristics
Contact resistance *1
Operate time
Release time
Insulation resistance *2
Between coil
and contacts
Dielectric Between
strength
contacts of
the same
polarity
Impulse withstand voltage
(between coil and contacts)
Destruction
100 mΩ max.
10 ms max.
5 ms max.
1,000 MΩ min.
3,000 VAC, 50/60 Hz for
1 min
750 VAC, 50/60 Hz for
1 min
6 kV (1.2 x 50
μs)
G
6
D
■Ordering
Information
Enclosure rating
Contact form
Terminal shape
Model
G6D-1A-ASI
Fully sealed
SPST-NO (1a)
PCB terminals
G6D-1A-ASI-AP
Note. When ordering, add the rated coil voltage to the model number.
Example: G6D-1A-ASI 5 VDC
Rated coil voltage
Rated coil voltage
5 VDC
12 VDC
24 VDC
12 VDC
24 VDC
Minimun packing
unit
25 pcs/tube
●Connecting
Socket
Applicable relay
G6D-1A-ASI
Model
P6D-04P
Minimun packing unit
25 pcs
■Ratings
●Coil
Item
Rated
current
(mA)
40
16.7
8.3
Coil
resistance
(Ω)
125
720
2,880
Must operate Must release
Max.
voltage
voltage
voltage
(V)
(V)
(V)
% of rated voltage
70% max.*
10% min.
160%
(at 23•C)
Power
consumption
(mW)
Approx. 200
Rated voltage
5 VDC
12 VDC
24 VDC
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of
±10%.
*2.
The operating characteristics are measured at a coil temperature of 23°C.
*3.
The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
* The must operate voltage is 75% or less of the rated voltage if the relay is mounted upside down.
●Contacts
Item
Contact Type
Contact material
Rated load
Rated carry current
Max. switching voltage
Max. switching current
*
Load
Resistive load
Single
Ag-Alloy (Cd free)
(Ag-alloy (Cd free) and Au plated)
5 A at 250 VAC
5 A at 30 VDC
5A
250 VAC, 30 VDC
5A
10 to 55 to 10 Hz, 0.75 mm
single amplitude (1.5 mm
double amplitude)
Vibration
resistance
10 to 55 to 10 Hz, 0.75 mm
Malfunction
single amplitude
(1.5 mm double amplitude)
Destruction
1,000 m/s
2
Shock
resistance Malfunction
100 m/s
2
20,000,000 operations min.
Mechanical
(at 18,000 operations/hr)
70,000 operations min.
(5 A at 250 VAC, resistive
load)
70,000 operations min.
(5 A at 30 VDC, resistive
Durability
load)
Electrical
300,000 operations min.
(2 A at 250 VAC, resistive
load)
30,000 operations min.
(2 A at 30 VDC, resistive
load)
(at 18,000 operations/hr)
Failure rate (P level)
10 mA at 5 VDC
(reference value *3)
(1 mA at 5 VDC) *4
Ambient operating
-25•C to 70•C (with no icing
temperature
or condensation)
Ambient operating humidity 5% to 85%
Weight
Approx. 3 g
Note. The data given above are initial values.
*1. Measurement conditions: 5 VDC, 1 A, voltage
drop method.
*2. Measurement conditions: The insulation
resistance was measured with a 500 VDC
megohmmeter at the same locations as the
dielectric strength was measured.
*3. This value was measured at a switching
frequency of 120 operations/min.
*4. The values indicated in parentheses ( ) are
for the G6D-1A-ASI-AP.
The content indicated in parentheses ( ) are for the G6D-1A-ASI-AP.
1
G6D
■Engineering
Data
●Maximum
Switching Capacity
Switching
current (A)
50
30
PCB Power Relay
●Durability
Durability (x10
4
operations)
500
300
●Ambient
Temperature vs.
Maximum Coil Voltage
Maximum coil voltage (%)
9
10
200
180
10
5
3
DC resistive load
1
0.5
0.3
DC inductive load
100
50
30
250 VAC/30 VDC resistive load
AC resistive load
160
140
AC inductive
load
cosφ=0.4
120
10
5 250 VAC/30 VDC inductive load
(cosφ=0.4/ L/R=7 ms)
3
100
80
60
0
23
30
40
50
60
70
80
90
Ambient temperature (°C)
0.1
0
3
5
10
30
100
250 500 1,000
Switching
voltage (V)
0
1
2
3
4
5
6
7
8
Switching
current (A)
Note. The maximum coil voltage is the maximum
voltage that can be applied to the relay coil.
●Ambient
Temperature vs. Must
Operate and Must Release
Voltages
G6D-1A-ASI (-AP)
Must operate
and
must release voltage (ratio of rated voltage) (%)
●Shock
Malfunction
G6D-1A-ASI (-AP)
G
6
D
100
Y
Sample:
G6D-1A-ASI
Number of Relays:
5 pcs
Must Operating voltage
Must Recovery voltage
X
max.
1,000
800
600
400
200
Z
80
60
X
min.
40
Z'
20
max.
X
min.
De-energized
206
X'
Shock
direction
X
X'
Y
Z
Z'
Y'
Coil terminals
Energized Y'
0
-40
-20
0
20
40
60
80
Unit: m/s
2
Ambient temperature (°C)
Sample: G6D-1A-ASI 24 VDC
Number of Relays: 5 pcs
Test conditions: Impose a shock in the ±X, ±Y, and ±Z
directions three times each with the Relay energized to
check the shock values that cause the Relay to
malfunction.
■Dimensions
G6D-1A-ASI (-AP)
0.5
17.5 max.
(17.3)*
6.5 max.
(6.4)*
2.54
Four, 1.1-dia.
(0.71)
12.5 max.
(12.4)*
3.5
0.5
2.54
7.62
5.08
*
Average value
0.8
5.08
0.3
(1.13)
10.16
5.08
1
2.54
5.08
13
5
7
PCB Mounting Holes
(Bottom View)
Terminal Arrangement/
Internal Connections
(Bottom View)
(No coil polarity)
Note: Orientation marks
are
indicated
as
follows:
Socket
P6D-04P
19.7 max.
(19.5)*
6.9 max.
(6.7)*
PCB Mounting Holes
(Bottom View)
2.54
Four, 1.1-dia.
(0.86)
2.54
6
±0.1
10.8
3.6
5.08
0.65
2.54
7.62
5.08
*
Average value
0.3
(2.18)
10.16
5.08
2
G6D
■Approved
Standards
PCB Power Relay
●The
rated values approved by each of the safety standards may be different from the performance characteristics individually defined in
this datasheet.
UL Recognized
(File No. E41515)
Model
G6D-1A-ASI (-AP)
Number of
poles
1
Coil ratings
5 to 24 VDC
Contact ratings
5 A, 250 VAC 40°C
5 A, 30 VDC 40°C
Number of test
operations
6,000
CSA Certified
Model
G6D-1A-ASI (-AP)
(File No. LR31928)
Number of
poles
1
Coil ratings
5 to 24 VDC
Contact ratings
5 A, 250 VAC (Resistive) 40°C
5 A, 30 VDC (Resistive) 40°C
Number of test
operations
6,000
EN/TÜV Certified
Model
G6D-1A-ASI (-AP)
(Registration No. R50167084)
Number of
poles
1
Coil ratings
5, 12, 24 VDC
Contact ratings
5 A, 250 VAC (cosφ=1.0) 70°C
5 A, 30 VDC (0 ms) 40°C
Number of test
operations
70,000
■Precautions
●Please
refer to “PCB Relays Common Precautions” for correct use.
Correct Use
●Mounting
• More than two relays can be closely
mounted right side up as shown in the
following illustration.
Upper
side
Upper
side
●Socket
Mounting Height
G
6
D
18.5 mm max.
6.5 mm
Current flow: 5 A max.
1.12 mm 7.62 mm in the
upside-down
direction
Current flow: 2 A max.
Note. The space between each relay required for
heat radiation may vary with operating
conditions. Contact your OMRON
representative for details.
●Mounting
to a P6D
• The P6D is flux-resistive. Do not wash
the P6D with water.
• Dismount the relay from the socket
before soldering the socket to a PCB.
• Use Surge Killer Diode when switching
a DC inductive load in micro load
(about 10 to 100 mA).
(Carbon deposition may decrease the
contact reliability.)
3
G6D
PCB Power Relay
G
6
D
•
Application examples provided in this document
are
for reference only. In
actual applications,
confirm equipment functions
and safety before using
the product.
•
Consult your OMRON representative
before using
the product
under
conditions which
are
not described in the manual or
applying
the product to nuclear control
systems,
railroad
systems, aviation systems,
vehicles, combustion
systems,
medical equipment,
amusement
machines,
safety
equipment,
and
other
systems
or equipment that may have
a serious
influence on lives
and
property if
used
improperly. Make
sure
that the ratings
and
performance characteristics of the product provide
a
margin of
safety
for the
system
or
equipment,
and be sure
to provide the
system
or equipment with double
safety
mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. K127-E1-03
0812(0207)(O)