• 1General purpose power Relays of single-pole10 A and double-pole 5 A.
• Safety-oriented design with dielectric strength of 5,000 V between coil
and contacts, and surge resistance of 10,000 V.
• AC and DC types are both available for operational coils.
RoHS Compliant
■Model
Number Legend
G2R-
@
-
@ @ @@
-@@
— ———— ——
1
2 3 4 5
6 7
1. Relay Function
None: Single-side stable
K : Double-winding latching
2. Number of poles
1: 1-pole
2: 2-pole
3. Contact Form
None: NO/NC
A : NO
4. Contact Type
None: Single
Z : Bifurcated contact
5. Enclosure rating
None: Flux protection
(T-type is an enclosed
relay)
4 : Fully sealed
6. Terminal Shape
None: PCB terminals
T : Quick-connect
(upper bracket
mounting #187)
7. Classification
None: Standard
E : High-capacity
H : High-sensitivity
U : For ultrasonically
cleanable
Z : Full-wave rectifier
G
2
R
■Model
Configuration
Number of poles
Terminal
Shape
Classification
Enclosure
rating
Flux protection
Standard
Fully sealed
Bifurcated
PCB terminals contact
High-capacity
High-sensitivity
Double-winding
latching
Quick-connect Standard
Flux protection
Fully sealed
Flux protection
Flux protection
Flux protection
Unsealed
Contact
form
AC
DC
AC
DC
DC
AC
DC
DC
DC
AC
DC
SPST-NO (1a)
G2R-1A
G2R-1A4
G2R-1AZ
G2R-1AZ4
G2R-1A-E
G2R-1A-H
G2RK-1A
G2R-1A-T
1-pole
SPDT (1c)
G2R-1
G2R-14
G2R-1Z
G2R-1Z4
G2R-1-E
G2R-1-H
G2RK-1
G2R-1-T
DPST-NO (2a)
G2R-2A
G2R-2A4
−
−
−
G2R-2A-H
G2RK-2A
−
2-pole
DPDT (2c)
G2R-2
100
pcs/tray
G2R-24
−
−
−
G2R-2-H
G2RK-2
−
50
pcs/tray
100
pcs/tray
50
pcs/tray
100
pcs/tray
Minimum
packing
unit
Note 1. Full-wave rectifier and supersonic cleaner compatible models are also available. Refer to page 3.
2. Sockets for PCB terminal models are not provided.
1
G2R
■Ordering
Information
●
PCB Terminal Models
Number of poles
Classification
Enclosure rating
Contact form
Model
1-pole
Rated coil voltage
12, 24, 100/(110) VAC
NO
Flux protection
NO/NC
Standard
NO
Fully sealed
NO/NC
G2R-14
G2R-1A4
G2R-1
G2R-1A
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
5, 6, 12, 24, 48 VDC
5, 6, 12, 24, 48 VDC
5, 6, 12, 24 VDC
5, 6, 12, 24 VDC
12, 24, 48 VDC
100 VDC
5, 6, 12, 24, 48 VDC
100 VDC
5, 12, 24, 48 VDC
100 VDC
5, 12, 24, 48 VDC
100 VDC
12, 24, 100/(110) VAC
NO
High-capacity
Flux protection
NO/NC
G2R-1-E
G2R-1A-E
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
Note: When ordering, add the rated coil voltage to the model number.
Example: G2R-1A AC12
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as
@@
VAC.
G2R-24
G2R-2A4
G2R-2
G2R-2A
Model
PCB Power Relay
2-pole
Rated coil voltage
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
G2R-2A-H
G2R-2-H
G2RK-2A
G2RK-2
5, 6, 12, 24, 48 VDC
5, 6, 12, 24, 48 VDC
5, 12, 24 VDC
5, 6, 12, 24 VDC
G
2
R
High-sensitivity
Flux protection
Double-winding
latching
NO
NO/NC
NO
NO/NC
NO
Flux protection
NO/NC
G2R-1A-H
G2R-1-H
G2RK-1A
G2RK-1
G2R-1AZ
G2R-1Z
G2R-1AZ4
G2R-1Z4
−
Bifurcated
contact
NO
Fully sealed
NO/NC
−
−
−
2
G2R
●
Quick-connect Terminal (#187)
Number of poles
Classification
Enclosure rating
Contact form
Model
1-pole
Rated coil voltage
12, 24, 100/(110) VAC
NO
Standard
Unsealed
NO/NC
G2R-1-T
G2R-1A-T
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100 VDC
PCB Power Relay
●
Full-wave Rectifier
Number of poles
Classification
Enclosure rating
NO
Flux protection
NO/NC
Standard
NO
Fully sealed
NO/NC
NO
NO/NC
G2R-14-Z
G2R-1A-EZ
G2R-1-EZ
G2R-1A4-Z
G2R-1-Z
Contact form
Model
G2R-1A-Z
1-pole
Rated coil voltage
5, 12, 24 VDC
100 VDC
5, 12, 24, 48 VDC
100 VDC
5, 12, 48 VDC
100 VDC
5, 12, 24, 48 VDC
100 VDC
5, 12, 24 VDC
100 VDC
12, 24, 48 VDC
−
Model
G2R-2A-Z
G2R-2-Z
G2R-2A4-Z
G2R-24-Z
2-pole
Rated coil voltage
5, 6, 12, 24, 48 VDC
100 VDC
12, 24, 48 VDC
100 VDC
24, 48 VDC
100 VDC
5, 12, 24 VDC
100 VDC
G
2
R
High-capacity
Flux protection
●
For Ultrasonically Cleanable
Number of poles
Classification
Enclosure rating
NO
Standard
Fully sealed
NO/NC
G2R-14-U
Contact form
Model
G2R-1A4-U
1-pole
Rated coil voltage
12, 24, 100/(110) VAC
200/(220) VAC
5, 6, 12, 24, 48 VDC
100/(110) VAC
200/(220) VAC
5, 12, 24, 48 VDC
100 VDC
Note: When ordering, add the rated coil voltage to the model number.
Example: G2R-1A-T AC12
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as
@@
VAC.
G2R-24-U
G2R-2A4-U
Model
2-pole
Rated coil voltage
100/(110) VAC
−
5, 12, 24 VDC
24, 100/(110) VAC
200/(220) VAC
5, 12, 24, 48 VDC
100 VDC
3
G2R
■Ratings
●
Coil
Item
Classification
•
•
•
•
Standard
Quick-connect
Fully sealed
High-capacity
Rated voltage
12 VAC
24 VAC
100/(110) VAC
200/(220) VAC
5 VDC
•
•
•
•
•
Standard
High-capacity
Bifurcated contact
Quick-connect
Fully sealed
6 VDC
12 VDC
24 VDC
48 VDC
100 VDC
5 VDC
6 VDC
• High-sensitivity
12 VDC
24 VDC
48 VDC
Rated current (mA)
50 Hz
93
46.5
11
5.5
106
88.2
43.6
21.8
11.5
5.3
71.4
60
30
15
7.5
60 Hz
75
37.5
9/(10.6)
4.5/(5.3)
Coil resistance
(Ω)
65
260
4,600
20,200
47
68
275
1,100
4,170
18,870
70
100
400
1,600
6,400
70% max.
15% min.
70% max.
15% min.
80% max.
30% min.
Must operate
voltage (V)
Must release
voltage (V)
% of rated voltage
PCB Power Relay
Max. voltage
(V)
Power
consumption
(VA, W)
140%
(at 23°C)
Approx. 0.9
(60 Hz)
170%
(at 23°C)
Approx. 0.53
170%
(at 23°C)
Approx. 0.36
G
2
R
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of+15%/-20% (AC rated current) or ±10% (DC coil resistance).
2. AC coil resistances shown above are only reference values.
3. The operating characteristics are measured at a coil temperature of 23°C.
4. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
●
Coil: Double-winding Latching Relays
Item
Rated voltage
5 VDC
6 VDC
12 VDC
24 VDC
Set Coil
Rated current
(mA)
167
138
70.6
34.6
Coil resistance
(Ω)
30
43.5
170
694
Reset coil
Rated current
(mA)
119
100
50
25
Coil resistance
(Ω)
42
60
240
960
70% max.
70% max.
140%
(at 23°C)
Approx.
850
Approx.
600
Must set
voltage (V)
Must reset Max. voltage
voltage (V)
(V)
Power consumption
Set Coil
(mW)
Reset coil
(mW)
% of rated voltage
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
4
G2R
●
Contacts: Flux Protection Type
Classification
Number of poles
Load
Item
Contact type
Contact material
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Failure rate (P level)
(reference value) *
10 A
100 mA at 5 VDC
10 A at
250 VAC
10 A at 30
VDC
7.5 A at
250 VAC
5 A at 30
VDC
5 A at 250
VAC
5 A at 30
VDC
2 A at 250
VAC
3 A at 30
VDC
16 A at
250 VAC
16 A at 30
VDC
Standard type
Quick-connect Terminal (1single-pole type)
1-pole
2-pole
High-capacity type
1-pole
Bifurcated contact type
2-pole
PCB Power Relay
High-sensitivity type
1-pole
2-pole
Inductive
Inductive
Inductive
Inductive
Inductive
Inductive
load
load
load
load
load
load
Resistive
Resistive
Resistive
Resistive
Resistive
Resistive
(cosφ = 0.4;
(cosφ = 0.4;
(cosφ = 0.4;
(cosφ = 0.4;
(cosφ = 0.4;
(cosφ = 0.4;
load
load
load
load
load
load
L/R = 7 ms)
L/R = 7 ms)
L/R = 7 ms)
L/R = 7 ms)
L/R = 7 ms)
L/R = 7 ms)
Single
Single
8 A at 250
VAC
8 A at 30
VDC
Bifurcated
Ag-alloy (Cd free)
5 A at 250
VAC
5 A at 30
VDC
2 A at 250
VAC
3 A at 30
VDC
5 A at 250
VAC
5 A at 30
VDC
2 A at 250
VAC
3 A at 30
VDC
3 A at 250
VAC
3 A at 30
VDC
1 A at 250
VAC
1.5 A at
30 VDC
Single
10 A
380 VAC, 125 VDC
5A
5A
10 mA at 5 VDC
16 A
380 VAC, 125 VDC
16 A
100 mA at 5 VDC
5A
5A
1 mA at 5 VDC
5A
380 VAC, 125 VDC
5A
100 mA at 5 VDC
3A
3A
10 mA at 5 VDC
* This value was measured at a switching frequency of 120 operations/min.
●
Contacts: Fully Sealed Type
Classification
Number of poles
Item
Contact type
Contact material
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Failure rate (P level)
(reference value) *
8 A at 250 VAC
8 A at 30 VDC
8A
380 VAC, 125 VDC
8A
100 mA at 5 VDC
6 A at 250 VAC
4 A at 30 VDC
Load
Resistive load
(cosφ = 1)
1-pole
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Single
4 A at 250 VAC
4 A at 30 VDC
4A
380 VAC, 125 VDC
4A
10 mA at 5 VDC
Resistive load
(cosφ = 1)
Standard type (Single contact type)
2-pole
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Single
Ag-alloy (Cd free)
1.5 A at 250 VAC
2.5 A at 30 VDC
5 A at 250 VAC
5 A at 30 VDC
5A
380 VAC, 125 VDC
5A
1 mA at 5 VDC
2 A at 250 VAC
3 A at 30 VDC
Resistive load
(cosφ = 1)
Bifurcated contact type
1-pole
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Bifurcated
G
2
R
* This value was measured at a switching frequency of 120 operations/min.
●
Contacts: Latching Type
Number of poles
Item
Contact type
Contact material
Rated load
Rated carry current
Max. switching voltage
Max. switching current
Failure rate (P level)
(reference value) *
5 A at 250 VAC
5 A at 30 VDC
5A
380 VAC, 125 VDC
5A
100 mA at 5 VDC
Load
Resistive load
(cosφ = 1)
1-pole
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Single
Ag-alloy (Cd free)
3.5 A at 250 VAC
2.5 A at 30 VDC
3 A at 250 VAC
3 A at 30 VDC
3A
380 VAC, 125 VDC
3A
10 mA at 5 VDC
1.5 A at 250 VAC
2 A at 30 VDC
Resistive load
(cosφ = 1)
2-pole
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Single
* This value was measured at a switching frequency of 120 operations/min.
I would like to ask an expert on LCD timer made of microcontroller, how to implement two independent timers on one screen, including independent operations, using touch method....
2021 is almost over. Today is January 20, the Great Cold in the lunar calendar. I heard a piece of news that if Qing Dynasty China had defeated the West, the world would basically use the lunar calend...
4 flashing lights
1. Project Background
The theory of LED lights and the schematic diagram of the teaching board have been described in detail in Case 1 : Flashing Light, so I will not repeat them her...
The reason for this is that the epidemic has caused me to work remotely from home, and I have to hold three or four remote meetings every day. My colleagues reported that my microphone is noisy becaus...
With the development of AV technology, the " home theater " VA combination has become an important part of modern family entertainment life. The AV combination introduced in this article adopts the c...[Details]
In recent years, with the continuous development of Internet technology and the increasing richness of film and television content, consumers' demand for smart TV product applications has continued t...[Details]
The basic block diagram of the PDP color TV microcontroller circuit is shown in the figure below. As can be seen from the figure, the microcontroller circuit is mainly composed of MCU and working c...[Details]
The basic scheduling principle was introduced earlier. Now let's apply it to the porting of ucos. If you don't understand scheduling yet, don't rush to port it, because the slightest error in the stac...[Details]
0 Introduction
Terminal guidance radar is one of the key components of the anti-ship missile guidance system. The quality of its performance directly affects the tactical and technical indicato...[Details]
As we all know, the domestic semiconductor industry has always been relatively weak in some upstream materials and equipment fields, among which photolithography machines and photoresists are the mo...[Details]
The sensor body of the open channel flow meter is made of plastic, so it is lightweight and corrosion-resistant. The open channel flowmeter has a simple structure and no moving parts. This flowmeter ...[Details]
The ballast reference design IRPLHID2 uses the IRS2573D device, with an input voltage of 185V-265V, and can drive 1 x 70W HID lamp. It has high power factor/low total harmonic distortion, controllable...[Details]
VIAVI Introduces CX300 ComXpert for Comprehensive Testing of LMR, PMR and LTE Wireless Devices in a Single Box
VIAVI CX300 ComXpert provides lab-grade, high-precision, full-featured ...[Details]
As shown in Figure A, it is a multivibrator circuit composed of CMOS NAND gates. It consists of two inverters, a resistor and a capacitor. Figure B is its waveform. In the figure, when waveform (1) j...[Details]
Advantech MIO-5152 3.5" single board, based on the 8th generation Elkhart Lake platform, outperforms J1900 and low-voltage I5, and can reach 10 TOPS computing power. Interface upgrades support 4K t...[Details]
Let's take the previous code relocation program as an example to take a quick look at the thumb instruction set. 1.C code is modified to Thumb instruction set format For C programs, if we want to c...[Details]
Apple today released the fourth beta of iOS 15.5 and iPadOS 15.5 for developers and public beta users to test. The new software was launched a week after the third beta was released. Developers can d...[Details]
Under the trend of green travel brought by the electrification of automobiles, many safety issues have also attracted people's attention. Here we are not only talking about autonomous driving, but ...[Details]
Auto-coupling step-down starting and star-delta starting are two commonly used motor starting methods. They have different effects on the current and torque of the motor during the starting process...[Details]