C 091 D
Characteristics
Standard
Characteristics
3
2
1
3
1
General Characteristics
Number of contacts
View on termination side
of male contact insert
Contact arrangement
Contact arrangement
Electrical Characteristics
Rated voltage
2)
Rated voltage
4
2 3
2
4
1
5
3
4
5
5 Stereo
4
1
2
5
3
3
2
1
6
4
6
5
5
6
7
4
7
1
3
2
7
4
1
6
7
2
5
3
4
1
8
G
12
E
F
14
E
F
G
D C
2
6
8
7
5
3
DC
L
O N
M
K
H J
M
K
H J
L
A
B
B
A
DIN EN
61076-2-106
IEC 60130-9
1)
IEC 60664-1
UL 1977
03-a
04-a
05-a
05-b
06-a
07-a
07-b
08-a
12-a
14-a
300 V ≃
(100 V ≃)
1500 V
(840 V)
300 V ≃ 100 V ≃
(63 V ≃) (32 V ≃)
250 V
1200 V
(500 V)
300 V ≃
(63 V ≃)
1500 V
(840 V)
1 (3
3)
)
I
II, 400 ≤ CTI < 600
100 V ≃
(32 V ≃)
1200 V
(500 V)
150 V ≃
(32 V ≃)
60 V
Rated impulse withstand voltage
2)
IEC 60664-1
Pollution degree
2)
Installation category
Insulation group
Current rating
Insulation resistance
Contact resistance
Climatic Characteristics
Climatic category
Temperature range
Salt Spray Resistance
Mechanical Characteristics
IP-degree
IEC 60529
25 N
90.oz
IEC 60668-1
IEC 60668-1
DIN IEC 60068-
2-11, Test Ka
IEC 60664-1
IEC 60664-1
IEC 60664-1
IEC 60512-5-2
UL 1977
IEC 60512-3-1
IEC 60512-2-1
5 A / + 40 °C / + 104 °F
please refer also to current derating curves page 59
> 10
10
Ω
4)
<5mΩ
40 / 100 / 56
- 40 °C ... + 100 °C / - 40 °F ... + 212 °F
720h
3 A / + 40 °C /
+ 104 °F
IP 67 and IP 65 (in mated condition)
30 N
110.oz
35 N
125.oz
50 N
180.oz
55 N
200.oz
60 N
220.oz
50 N
180.oz
Insertion and withdrawal forces IEC 60512-13-2
Mechanical operation
Materials
Housing material
Dielectric material
Contact plating
Further Characteristics
Termination technique
Wire gauge
IEC 60512-9-1
Silver ≥ 500 mating cycles
Gold ≥ 1000 mating cycles
coupling ring brass, strain relief, die cast, nickel plated
thermoplastic
silver plated / gold plated
5)
solder, crimp
solder: ≤ 0,5 mm
2
/ 20 AWG
crimp: 2 - 6 pol (excluding 5S): 0,09 - 1,00 mm
2
/ 28 - 18 AWG
crimp: 5S, 7, 7S and 8-pol.: 0,09 - 0,75 mm
2
/ 28 - 20 AWG
UL 94 V0
solder: ≤ 0,25 mm² /
24 AWG
crimp: 0,09-0,25 mm²
/ 28 – 24 AWG
Flammability
Locking system
IEC 60130-9
DIN EN
61076-2-106
UL 1977
metal screw coupling; tightening torque 0,7 Nm
Conditions of acceptability
UL
Caution:
Do not connect or disconnect under load. Metal housing parts shall be securely incorporated to protected ground.
1)
Edition 2000-05
2)
values in brackets are according to DIN EN 61076-2-106
3)
designed acc. pollution degree 2; can be used under pollution degree 3 when the rules of IEC 60644-1 are fulfilled
4)
under operating conditions >10
8
Ω
5)
Remark for gold plated contacts: In order to avoid brittle inter-metallic connections, gold-plated terminals have to be tin-plated in the solder area.
IEC 60 664 ^ DIN VDE 0110 ; IEC 60 512-x ^ DIN EN 60 512-x; IEC 60 130-9 ^ DIN EN 60 130-9; IEC 61076-2-106 ^ DIN EN 61076-2-106
=
=
=
=