EEWORLDEEWORLDEEWORLD

Part Number

Search

TCP312A

Description
Test Probes ProbeAC/DC;21.2A RMS 100MHz BW;BNC Interf
CategoryTopical application    Test and measurement   
File Size208KB,6 Pages
ManufacturerTektronix
Websitehttps://www.tek.com/
Download Datasheet Parametric Compare View All

TCP312A Online Shopping

Suppliers Part Number Price MOQ In stock  
TCP312A - - View Buy Now

TCP312A Overview

Test Probes ProbeAC/DC;21.2A RMS 100MHz BW;BNC Interf

TCP312A Parametric

Parameter NameAttribute value
Product CategoryTest Probes
ManufacturerTektronix
RoHSDetails
Equipment TypeCurrent Probes
TypeCurrent Probes
Bandwidth100 MHz
Tip StyleFlat
Length7.77 in
ColorBlack
Current Rating50 A
Factory Pack Quantity1
Unit Weight2.254 lbs
AC/DC Current Measurement Systems
TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet
Low DC drift and noise allows improved low-level current
measurements
3rd party safety certification
2
Requires a TDS TEKSCOPE oscilloscope or a TekConect oscilloscope
with TCA-BNC adapter
Applications
Development and analysis solutions for designers, installers, and
service personnel in telecom, data comm, computer, and
semiconductor power electronics environments for:
Power supplies (switching and linear)
The TCP300 and TCP400 Series AC/DC current measurement family is a
highly advanced current measurement system for today's current
measurement needs. When connected to Tektronix oscilloscopes with
TEKPROBE Level II, TekConnect (w/ TCA-BNC), or TekVPI (w/ TPA-BNC)
interfaces, current measurements and calculations are simple and easy.
Semiconductor devices (SCRs, IGBTs, MOSFETs, CMOS, BJTs)
Power inverters/converters
Electronic ballasts
Industrial/consumer electronics
Mobile communications (phone, satellite, relay stations)
Motor drives
Transportation systems (electronic vehicles, electric trains, locomotives,
avionics)
Key performance specifications
DC - 100 MHz, Current Probe Amplifier (TCPA300) uses:
DC - 100 MHz, 30 A DC (TCP312A)
DC - 50 MHz, 50 A DC (TCP305A)
DC - 15 MHz, 150 A DC (TCP303)
DC - 50 MHz, Current Probe Amplifier (TCPA400) Uses:
1
Derated
DC - 2 MHz, 750 A DC
1
(TCP404XL) (500 A DC Continuous)
with duty cycle
Meets today's AC/DC current measurement
applications
The TCPA300 amplifier, when used with TCP312A, TCP305A, or TCP303
probes, provides a wide range of current measurement capability and spans
the gap between low-level milliamp measurements to very high current
levels. These three probes provide current measurement capabilities of
30 A, 50 A, and 150 A DC continuous. For even higher current levels, the
TCPA400 amplifier with the TCP404XL current probe measures 500 A DC
continuous and 750 A DC continuous, derated with duty cycle.
Higher-frequency performance is available with the TCP312A w/TCPA300
providing ≥100 MHz bandwidth and a maximum current of 30 A DC.
Key features
Automatic scaling and units
2
- Oscilloscope on-screen readout of
magnitude and amps reduces measurement errors with no more hand
calculations
AC/DC input coupling
Low insertion impedance reduces device under test loading
Split-core construction allows easy circuit connection
Status indicators provide visual operating status and notification of
potential error conditions - degauss, probe open, overload, not
terminated into 50 Ω, noncompatible probe type

TCP312A Related Products

TCP312A TCP305A
Description Test Probes ProbeAC/DC;21.2A RMS 100MHz BW;BNC Interf Hand Tools TOOL, INSERT/EXTRACT
Product Category Test Probes Test Probes
Manufacturer Tektronix Tektronix
RoHS Details Details
Equipment Type Current Probes Current Probes
Type Current Probes Current Probes
Bandwidth 100 MHz 50 MHz
Tip Style Flat Flat
Length 7.77 in 7.77 in
Color Black Black
Current Rating 50 A 50 A
Factory Pack Quantity 1 1
Unit Weight 2.254 lbs 2.600 lbs
7 good habits of PCB layout engineers
In the eyes of some people, the work of PCB layout engineers is a bit boring. Every day, they have to deal with thousands of wiring on the board, various packages, and repeat the work of pulling wires...
mwkjhl PCB Design
Switching Power Supply Interest Group Task 07
[i=s]This post was last edited by maychang on 2020-9-18 10:18[/i]  Question 06:  1. We know that the Buck circuit has two working states: continuous inductor current and discontinuous inductor current...
maychang Switching Power Supply Study Group
The first to support all open source smart home protocols running simultaneously - QPG7015M
As the core of the home IoT system, the gateway supports multiple applications, security protocols, and data through the central device it is located in. For example, IoT applications that support lig...
alan000345 RF/Wirelessly
I would like to ask why the electric bicycle occasionally appears to be locked by the remote control even though it has never been locked using the remote control?
I would like to ask why my electric bicycle is occasionally locked by the remote control. I have never locked it with the remote control. The remote control has been in a drawer and has never been use...
深圳小花 MCU
【Power amplifier application】 Lamb wave signal analysis based on dry-coupled ultrasonic testing
The dry coupling ultrasonic testing method does not require the application of liquid coupling agents such as water or oil on the surface of the material to be tested. It is easy to operate and flexib...
aigtek01 Test/Measurement
Working of LM331
LM311 is a voltage-frequency conversion chip produced by National Semiconductor (NS). After National Semiconductor was acquired by Texas Instruments (TI), it became a product produced by Texas Instrum...
maychang TI Technology Forum

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号