New Product
Multifunction Counter/Tachometer
H7CX-@
-N
Ultra-compact Counter Provides More
Complete Functionality.
Basic Features
• Short body with depth of only 59 mm (for 12 to 24-VDC Models with Screw Terminals).
*1
• Better readability with character height of 12 mm on 4-digit models and 10 mm
on 6-digit models.
• The present value display characters can be switched between red, green, and orange.
*2
Safety and Reliability
• New set value limit and counter functions have been added.
Other Features
• Front Panel can be changed to white or light gray.
*3
• New models with two tachometer inputs and two tachometer outputs have
been added to the series.
*4
*1.For 100 to 240-VAC Models with Screw Terminals: 78 mm, Models with Sockets: 63.7 mm
(case dimension).
*2.The H7CX-A11 and H7CX-R11 have only red characters.
*3.The Front Panel can be replaced with an optional Front Panel (except for Tachometer-only Models).
*4.Only one prescale value provided.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Refer to
Safety Precautions
on page 52.
Features
Basic Features
Ultra Short Body
The body depth has been greatly reduced. Helps in making thinner control panels.
12 to 24-VDC Models with Screw Terminals: 59 mm
100 to 240-VAC Models with Screw Terminals: 78 mm*
Models with Sockets: 63.7 mm (case dimension)
* Power supply circuit and input circuits are isolated for safety and reliability.
Safety and Reliability
Isolated Power Supply and Input Circuits
Power supply circuit and input circuits are isolated inside the Counter/
Tachometer. Previous non-isolated counters had wiring restrictions
and could be damaged if wired incorrectly. The H7CX removes these
worries.
Note:
Except 12 to 24-VDC models.
Set Value Limit
You can set an upper limit for the set value to prevent unexpected
operation of output devices caused by setting mistakes.
New models
Previous
models
Easier to Read
For better readability, the character height for the present value
display is 12 mm on models with 4 digits, the largest class in the
industry. The wide viewing angle and brightness provide excellent
visibility. The number of display segments has also been increased to
make settings easier to understand, and the present value display
can be switched between red, green, and orange so that output status
can be seen from a distance.
Model with 4 Digits
Model with 6 Digits
10 mm
(actual size)
New
Previous
models
models
Setting the upper limit of the set
value enables worry-free operation.
No overflow
For 1,000 pieces
12 mm
(actual size)
Output Counter
The output counter counts the number of times the output turns ON
(alarms can be displayed and the count can be monitored in
increments of 1,000 operations). This counter is useful in managing
the service life of the Counter/Tachometer or the load.
(Display example)
Easy to read from the top, bottom,
and sides!
Note:
The display color can be switched on all models except for the
H7CX-A11 and H7CX-R11.
The Easiest Operation
Operation is simplified by the
Up/Down Key for each digit
on 4-digit models and Up
Key for each digit on 6-digit
models.
Model with 4 Digits
Model with 6 Digits
1
H7CX-@-N
Other Features
The front color can be changed simply by
replacing the Front Panel.
The Front Panel can be replaced with an optional Front Panel (sold
separately) with a different color to match the installation site. Select
from black, white, and light gray (except for models with tachometer
function only).
Key Protection
Select from any of seven protection patterns. Use the best one for the
application.
New Functions
Many useful functions have been added, including a Twin Counter
Mode and many tachometer functions to handle even more
applications.
New Tachometer Functions
• Control with two independent inputs (independent measurements,
differential, absolute ratio, and error ratio)
• Peak/bottom hold function
• Output hysteresis setting
• Output OFF delay
• Switching the measurement method (pulse cycle/pulse width)
• Startup time
• Auto-zero time
• Averaging method/Number of averaging times
• AMD-compatible Mode
Note:
Refer to
“Model Configuration”
below, for details on applicable
functions.
Black
(Standard)
White
Light gray
Only the Front
Panel can be
replaced.
Universal NPN/PNP Input
DC 2-wire sensors can be connected for a wide range of input
devices.
Waterproof, Dust-proof Structure (UL508 Type
4X and IP66)
Worry-free application is possible in locations subject to water.
Note:
When the Y92S-29 Waterproof Packing is used.
Model Number Structure
Model Configuration
H7CX Series
H7CX-A-series Multifunction Preset Counter
H7CX-R-series Digital Tachometer
Model
Classification
Model
1-stage preset
counter
2-stage preset
counter
Function
Total and preset
counter
Batch counter
Dual counter
Twin counter
Tachometer
Preset counter
H7CX-A@-N
Yes
No
Yes
No
No
No
No
H7CX-A4W@-N
Yes
Yes
Yes
Yes
Yes
Yes
No
Preset counter/tachometer
H7CX-AW@-N/-AU@-N
Yes
Yes
Yes
Yes
Yes
Yes
Yes
*1
Tachometer
H7CX-R11@-N
No
No
No
No
No
No
Yes
H7CX-R11W@-N
Tachometer input
No
No
Yes
1 input or 2 inputs
(independent
measurements, differential,
absolute ratio value, and
error ratio value)
2-stage
Yes
1 input
Yes
2 inputs (independent
measurement) only
Settings
External connections
Display color of present value
Display digits
1-stage
11-pin socket
Red
4 or 6 digits
1-stage
11-pin socket
Red
6 digits
6 digits
Screw terminals
Red, green, or orange
4 digits
*1. Set the tachometer input mode from the function setting mode to switch to the tachometer function.
2
H7CX-@-N
Model Number Legend
(Not all possible combinations of functions are available.)
H7CX-@@@@@@-N
1 2 3 4 5 6
1. Type
Symbol
A
R
Meaning
Standard type
Tachometer
2. External connections
Symbol
None
11
Meaning
Screw terminals
11-pin socket
3. Digits
Symbol
None
4
Meaning
6 digits
4 digits
4. Settings
Symbol
None
U
W
Meaning
1-stage setting
Factory-set to 1-stage setting
Factory-set to 2-stage setting*
5. Output type
Symbol
None
S
Meaning
Contact output or contact output +
transistor output
Transistor output
6. Supply voltage
Symbol
None
D
D1
Meaning
100 to 240 VAC at 50/60 Hz
12 to 24 VDC
12 to 24 VDC/24 VAC at 50/60 Hz
* The H7CX-R11W@ is a 1-stage (2 inputs and outputs)
rather than a 2-stage Counter.
Note:
Estimates can be provided for coatings and other specifications that are not given in the datasheet. Ask your OMRON representative for details.
Ordering Information
List of Models
Type
Classification
Configuration
External
connections
Settings
Display
digits
4 digits
11-pin socket
6 digits
• 1-stage preset
counter
• Total and preset
counter
Outputs
Contact output (SPDT)
Transistor output (SPST)
Contact output (SPDT)
Contact output (SPDT)
Transistor output (SPST)
Contact output (SPDT)
Transistor output (SPST)
1-stage
4 digits
Contact output (SPDT)
Transistor output (SPST)
Contact output (SPDT)
Transistor output (SPST)
Contact output (SPDT)
6 digits
Transistor output (SPST)
Contact output (SPDT)
Transistor output (SPST)
H7CX-A
Series
• 1-stage preset
counter
• 2-stage preset
counter
• Total and preset
counter
• Batch counter
• Dual counter
• Twin counter
Power supply
voltage
100 to 240 VAC
Model
H7CX-A114-N
H7CX-A114S-N
H7CX-A11-N
H7CX-A11S-N
H7CX-A11D1-N
H7CX-A11SD1-N
H7CX-A4-N
H7CX-A4S-N
H7CX-A4D-N
H7CX-A4SD-N
H7CX-A-N
H7CX-AS-N
H7CX-AD-N
H7CX-ASD-N
H7CX-A4W-N
12 to 24 VDC/24 VAC
H7CX-A114D1-N
100 to 240 VAC
12 to 24 VDC/24 VAC
100 to 240 VAC
12 to 24 VDC
100 to 240 VAC
12 to 24 VDC
Preset counter
Contact output (SPST + SPDT) 100 to 240 VAC
Screw
terminals
4 digits
Transistor output (DPST)
12 to 24 VDC
H7CX-A4WSD-N
Contact output (SPST + SPDT)
• 1-stage preset
counter
• 2-stage preset
counter
• Total and preset
counter
• Batch counter
• Dual counter
• Twin counter
• Tachometer
2-stage
Transistor output (DPST)
Contact output (SPST + SPDT)
Transistor output (DPST)
6 digits
Contact output (SPDT) +
Transistor output (SPST)
Contact output (SPDT) +
Transistor output (SPST)
Transistor output (DPST)
1-stage
(1 input and
output)
1-stage
(2 inputs and
outputs)
100 to 240 VAC
12 to 24 VDC/24 VAC
12 to 24 VDC
100 to 240 VAC
H7CX-AW-N
H7CX-AWS-N
H7CX-AWD1-N
H7CX-AWSD1-N
H7CX-AWSD-N
H7CX-AU-N
H7CX-AUD1-N
H7CX-AUSD1-N
Preset counter/
Tachometer
12 to 24 VDC/24 VAC
100 to 240 VAC
H7CX-R11-N
Contact output (SPDT)
6 digits
Contact output (SPDT + SPST)
H7CX-R
Series
12 to 24 VDC/24 VAC
H7CX-R11D1-N
100 to 240 VAC
H7CX-R11W-N
Tachometer
• Tachometer
11-pin socket
12 to 24 VDC/24 VAC
H7CX-R11WD1-N
Note: 1.
The functions that are provided depend on the model. Check detailed specifications before ordering.
2.
Refer to page page 37 and later for information on H7CX-R Tachometers.
3
H7CX-@-N
Accessories (Order Separately)
Front Panels (Replacement Part)
Model
Y92P-CXC4G
Y92P-CXC4S
Y92P-CXC4B
Y92P-CXC6G
Y92P-CXC6S
Y92P-CXC6B
Color
Light gray (5Y7/1)
White (5Y9.2/0.5)
Black (N1.5)
Light gray (5Y7/1)
White (5Y9.2/0.5)
Black (N1.5)
6-digit Counter
12
Applicable Counters
4-digit Counter
Page
Note: 1.
You can change the color of the Front Panel when mounting the Counter. The Counter is shipped with a black (N1.5) Front Panel.
2.
"COUNTER" is printed on the front of Replacement Front Panels.
Soft Cover
Model
Y92A-48F1
---
Remarks
Page
12
Hard Cover
Model
Y92A-48
---
Remarks
Page
12
Flush Mounting Adapter
Model
Y92F-30
Remarks
Included with models with screw
terminals.
Use this Adapter to install the Counter/
Tachometer in a cutout previously made
for a DIN 72
×
72 mm device (panel
cutout: 68
×
68 mm).
12
Page
Y92F-45
Waterproof Packing
Model
Y92S-29
Remarks
Included with models with screw
terminals.
Page
12
Connection Sockets
Model
P2CF-11
P2CF-11-E
Classification
Front-connecting Socket
Front-connecting Socket (Finger-safe
Type)
Connectable
Counter/
Tachometers
---
Round crimp terminals cannot be used on
Finger-safe Sockets.
Use forked crimp terminals.
A Y92A-48G Terminal Cover can be used
with the Socket to create a finger-safe
construction.
Remarks
Page
H7CX-@11@-N
13
P3GA-11
Back-connecting Sockets
Terminal Covers for P3GA-11 Back-connecting Socket
Model
Y92A-48G
---
Remarks
Page
13
4
H7CX-A@-N
H7CX-A@-N Multifunction Preset Counter
• Easy to check the output status from a long distance with
changing display colors
*1
(red, green, and orange).
• Includes total and preset counter, batch counter, dual counter,
twin counter, and tachometer.
*2
*1. Not supported by the H7CX-A11@-N.
*2. The functions that can be selected depend on the model.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Specifications
Ratings
Item
Classification
Models
H7CX-A114@-N
Preset counter
H7CX-A11@-N
H7CX-A4@-N
H7CX-A@-N
H7CX-A4W@-N
H7CX-AW@-N/-AU@-N
Preset counter/
tachometer
Configuration
1-stage preset counter, 1-stage preset counter with total counter (selectable)*1
1-stage/2-stage preset
counter, total and preset
counter*1, batch
counter, dual counter,
and twin counter
(selectable)
1-stage/2-stage preset
counter, total and preset
counter*1, batch
counter, dual counter,
twin counter, and
tachometer (selectable)
• 100 to 240 VAC at 50/
60 Hz
• 24 VAC at 50/60 Hz or
12 to 24 VDC
• 12 to 24 VDC
Power supply
voltage*2
Ratings
Operating volt-
age fluctuation
range
Power con-
sumption
Mounting method
External connections
Degree of protection
Input signals
Maximum
counting speed
Input mode
Counter
Output mode
One-shot out-
put time
Reset system
Tachometer
Prescaling function
Decimal point adjustment
Sensor waiting time
• 100 to 240 VAC, 50/60 Hz
• 24 VAC, 50/60 Hz or 12 to 24 VDC
• 100 to 240 VAC, 50/60 Hz
• 12 to 24 VDC
85% to 110% of rated supply voltage (12 to 24 VDC: 90% to 110%)
Approx. 9.4 VA at 100 to 240 VAC, Approx. 7.2 VA/4.7 W at 24 VAC/12 to 24 VDC, Approx. 3.7 W at 12 to 24 VDC
Flush mounting or surface mounting
11-pin socket
CP1, CP2, reset, and total reset
Flush mounting
Screw terminals
CP1, CP2, reset 1, and reset 2
IEC IP66, UL508 Type 4X (indoors) for panel surface only and only when Y92S-29 Waterproof Packing is used.
30 Hz (minimum pulse width: 16.7 ms) or 5 kHz (minimum pulse width: 0.1 ms) (selectable) (ON/OFF ratio 1:1)*3
*Common setting for CP1 and CP2
Increment, decrement, increment/decrement (UP/DOWN A (command input), UP/DOWN B (individual inputs), or UP/DOWN C (quadrature inputs))
N, F, C, R, K-1, P, Q, A, K-2, D, and L.
0.01 to 99.99 s
External (minimum reset signal width: 1 ms or 20 ms, selectable), manual, and automatic reset (internal according to C, R, P, and Q mode operation)
Refer to the separate table for tachometer function ratings.
Yes (0.001 to 9.999)
Yes (rightmost 3 digits)
290 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
No-voltage inputs:
ON impedance: 1 kΩ max. (Leakage current: 12 mA at 0
Ω)
ON residual voltage: 3 V max.
OFF impedance: 100 kΩ min.
Voltage input:
High (logic) level: 4.5 to 30 VDC
Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)
No-voltage input/voltage input (selectable)
12 VDC (±10%), 100 mA (except for H7CX-A@D models) Refer to
Precautions for Correct Use
on page page 53 for details.
• Contact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1), Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value)
• Transistor output: NPN open collector, 100 mA at 30 VDC, Residual voltage: 1.5 VDC max. (approx. 1 V), Leakage current: 0.1 mA max.
7-segment, negative
transmissive LCD
Character height
Count value: 12 mm
(red)
Set value: 6 mm (green)
4 digits
−999
to 9999
(−3 digits to +4 digits)
7-segment, negative
transmissive LCD
Character height
Count value: 10 mm
(red)
Set value: 6 mm (green)
6 digits
−99999
to 999999
(−5 digits to +6 digits)
7-segment, negative
transmissive LCD
Character height
Count value: 12 mm
(red, green, or orange
selectable)
Set value: 6 mm (green)
4 digits
−999
to 9999
(−3 digits to +4 digits)
7-segment, negative
transmissive LCD
Character height
Count value: 10 mm
(red, green, or orange
selectable)
Set value: 6 mm (green)
6 digits
−99999
to 999999
(−5 digits to +6 digits)
7-segment, negative
transmissive LCD
Character height
Count value: 12 mm
(red, green, or orange
selectable)
Set value: 6 mm (green)
4 digits
−999
to 9999
(−3 digits to +4 digits)
7-segment, negative
transmissive LCD
Character height
Count value: 10 mm
(red, green, or orange
selectable)
Set value: 6 mm (green)
6 digits
−99999
to 999999
(−5 digits to +6 digits),
tachometer: 0 to 999999
Yes (0.001 to 99.999)
Yes (0.001 to 9.999)
Yes (0.001 to 99.999)
Yes (0.001 to 9.999)
Yes (0.001 to 99.999)
N, F, C, R, K-1, P, Q, A, K-2, D, L, and H.
Input method
External power supply
Control output
Display*4
Digits
Memory backup
Operating temperature
range
Storage temperature range
Operating humidity range
Case color
Attachments
EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
−10
to 55°C (−10 to 50°C if Counter/Tachometers are mounted side by side) (with no icing or condensation)
−25
to 70°C (with no icing or condensation)
25% to 85%
Black (N1.5) (Optional Front Panels are available to change the Front Panel color to light gray or white.)
---
Flush mounting adapter, waterproof packing, terminal cover
Flush mounting adapter,
waterproof packing,
terminal cover, label for
DIP switch settings
*1. 1-stage preset counter and total counter functionality.
*2. Do not use the output from an inverter as the power supply.The ripple must be 20% maximum for DC power.
*3. A response of 10 kHz (minimum pulse width: 0.05 ms) is possible if the response speed is 5 kHz and the 1-stage preset counter input mode is increment,
decrement, or increment/decrement (command input).
*4. The display is lit only when the power is ON. Nothing is displayed when power is OFF.
5