1. At full load, 100 ~ 240 Vac input, 20 MHz bandwidth oscilloscope, each output terminated with 10 µF aluminum electrolytic and 0.1 µF ceramic capacitors.
IS
C
PART NUMBER KEY
ETS135890U
X C
-
P51
- ET
- CXX
example of 13.5 Vdc, 8.9 A
Base Number
D
ED
ripple
1
efficiency
level
max
(mVp-p)
FEATURES
200
200
200
200
250
250
250
250
V
V
V
V
V
V
V
V
Reserved for Custom
Configurations
Factory
Designation
For more information, please visit the
product page
|
For information on related products, view
Dc Power Jacks
CUI Inc
│
SERIES:
ETS 150W U
│
DESCRIPTION:
AC-DC POWER SUPPLY
date
11/26/2014
│
page
2 of 5
INPUT
parameter
voltage
frequency
current
inrush current
no load power consumption
power factor correction
complies with IEC 61000-3-2 class D, at 100 Vac
harmonic standard, input power > 75W, at 240 Vac
at 230 Vac, cool start
conditions/description
min
90
47
typ
max
264
63
2.5
0.5
100
units
Vac
Hz
A
A
0.95
0.9
OUTPUT
parameter
load regulation
conditions/description
min
N
U
±5
140
140
min
typ
min
0
-20
20
0
typ
cui.com
PROTECTIONS
parameter
over voltage protection
over current protection
short circuit protection
auto restart
conditions/description
SAFETY & COMPLIANCE
parameter
isolation voltage
safety approvals
EMI/EMC
RoHS compliant
MTBF
conditions/description
TI
input to output at 10 mA for 1 second
UL/cUL (60950-1), EN 60950-1/IEC 60950-1, CSA C22 60950-1-03
O
N
yes
conditions/description
FCC Part 15 Class B, CE, CNS 13438 class B, CISPR 22 class B, EN 55022; EN 55024; EN 61000-(2, 3);
IEC 61000-4-(2, 3, 4, 5, 6, 8, 11)
40,000
hours
ENVIRONMENTAL
parameter
operating temperature
storage temperature
operating humidity
storage humidity
IS
C
D
ED
W
typ
max
units
%
%
%
max
1,800
units
Vac
max
40
85
80
90
units
°C
°C
%
%
For more information, please visit the
product page
|
For information on related products, view
Dc Power Jacks
CUI Inc
│
SERIES:
ETS 150W U
│
DESCRIPTION:
AC-DC POWER SUPPLY
date
11/26/2014
│
page
3 of 5
MECHANICAL
parameter
dimensions
input plug
conditions/description
160 x 65 x 49.5 (6.3 x 2.56 x 1.95 inch)
IEC320/C14 or IEC320/C6
min
typ
max
units
mm
MECHANICAL DRAWING
units: mm
IS
C
O
N
Standard:
IEC 320 C14 input plug
Optional:
IEC 320 C6 input plug
cui.com
D
TI
N
U
ED
For more information, please visit the
product page
|
For information on related products, view
Dc Power Jacks
CUI Inc
│
SERIES:
ETS 150W U
│
DESCRIPTION:
AC-DC POWER SUPPLY
date
11/26/2014
│
page
4 of 5
AC CORD
N
U
O
N
cui.com
D
IS
C
TI
ED
C6
C14
For more information, please visit the
product page
|
For information on related products, view
Dc Power Jacks
CUI Inc
│
SERIES:
ETS 150W U
│
DESCRIPTION:
AC-DC POWER SUPPLY
date
11/26/2014
│
page
5 of 5
REVISION HISTORY
rev.
1.0
1.01
1.02
description
initial release
updated datasheet
V-Infinity branding removed, safety and EMI/EMC data updated
date
The revision history provided is for informational purposes only and is believed to be accurate.
IS
C
O
N
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to