DC negative high voltage generator
Source: InternetPublisher:抄写员 Keywords: generator Updated: 2024/09/29
The DC negative high voltage generator shown in the figure is specially designed for high voltage electrostatic spraying equipment. The circuit is small in size, low in power consumption, and the output negative high voltage is stable and continuously adjustable, with a maximum output of 100,000 volts DC high voltage. It has overload protection, automatic stop, and automatic recovery functions.
Component Selection:
T1 is a 30-40W, 2×24V power transformer. T2 and T3 are black-and-white TV line drive transformers. T4 is a 17-inch black-and-white TV discrete line output transformer. VT5 can be selected from 3DDl5D, 3JL06, etc. RPl is a 20k12 multi-turn potentiometer. The silicon column withstand voltage in the voltage doubler box should be above 20kV. The capacitor is Japanese-made 510pF/30kΩ. The parameter values of other components are selected as marked in the figure.
- LC oscillator and common circuits
- LM324 op amp makes a step wave generator
- Quartz crystal sine oscillator
- Complementary symmetric astable multivibrator circuit diagram
- Analog-to-digital converter application circuit design analysis
- Field effect transistor RC bridge oscillation circuit
- 1MHz crystal calibrator
- 1kHz to 1MHz sinusoidal oscillator circuit
- TTL level oscillator
- Variable start/stop ramp oscillator