Liquid level and temperature monitoring circuit diagram
Source: InternetPublisher:清宁时光 Keywords: Temperature monitoring circuit diagram monitoring circuit Updated: 2021/02/26
In the circuit, if the thermistor K273 reaches the set temperature or the sensor electrode at the liquid level 2 is no longer immersed in the liquid, the relay is turned on to heat it. This ensures that when heating is switched on there is always a minimum amount of liquid in the container.
This circuit can also be used to monitor other liquid levels. As shown in the figure, the sensor of liquid level 1 is connected to the differential amplifier, and the other contacts of the relay can be used to stop the supply of liquid when the required liquid level is reached, thereby keeping the liquid level unchanged.
Main technical data: Working voltage: 15V Adjustable temperature: 25, 60 or 95 degrees Celsius Temperature deviation at voltage fluctuation (+10~-15%) and temperature change (0~70 degrees Celsius): 1 degree Celsius. ck=" window.open(this.src)" alt="Click to see larger image" />
- DC motor drive circuit composed of L293D
- Simple phase failure protection circuit composed of intermediate relay
- One-way rotation circuit of motor controlled by contactor
- Design and analysis of wire control circuit
- An experimental model of an infrared radio alarm
- Infrared blocking alarm device
- Large range laser burglar alarm
- Range hood automatic controller
- Delayed electronic fuse
- New type of wind and rainproof automatic window that is simple and easy to make
- Mobile phone camera flash control circuit
- Switching regulated power supply circuit
- Boiler control circuit
- Paper tension control circuit
- AM radio automatic search and trigger circuit
- Photoelectric output control circuit
- Relay control circuitb
- Microwave heating component control circuit schematic diagram
- Forward and reverse control circuit of micro DC motor b
- Power supply circuit with multiple outputs (MAX1902)