Power outage emergency light circuit (2)

Source: InternetPublisher:奥特man123 Keywords: Emergency lights BSP batteries Updated: 2021/08/31

282.Power outage<strong>Emergency light</strong><strong>Circuit</strong> (2).gif

Figure 282 shows another simple power outage
emergency light circuit . When the power grid stops supplying normal power, the mains
power is stepped down by T, rectified by VD1~VD4, filtered by C- and passed through R. and VD5 to charge the battery (;. At this time,
VT1 is closed and R. is forward-biased and conducts, and its collector is at low potential, so V, r2 is cut off, and the small light F does not light up. When the city
lu suddenly loses power, due to the isolation of VD5 , G
will not pass through R. Supply power to the base of VT1, VT]
is cut off due to a power outage, thereby releasing
the blockade of VT2, VT2 is turned on because the base passes through the ruler. It obtains bias current from the battery G
, and the emergency light E is powered on The requirements for light emission
,
    voltage regulator T, battery (G) and small lamp E are
the same as those in the seven examples. The parameters of other components are shown in the figure. There are no
special requirements.


EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

About Us Customer Service Contact Information Datasheet Sitemap LatestNews


Room 1530, 15th Floor, Building B, No.18 Zhongguancun Street, Haidian District, Beijing, Postal Code: 100190 China Telephone: 008610 8235 0740

Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号