Human body infrared detection alarm
Source: InternetPublisher:常思一二 Keywords: Infrared alarm delay circuit Updated: 2021/04/18
The alarm we introduced this time uses the detection of infrared rays emitted by the human body and consists of an infrared sensor, a signal amplifier circuit, a voltage comparator, a delay circuit and an audio alarm circuit. When the infrared detection sensor IC 1 detects the infrared signal radiated by the human body in front, the ② pin of IC1 outputs a weak electrical signal, which is amplified by the first-stage amplification circuit composed of the transistor VT1, etc., and then input to the operational amplifier IC2 through C2 for high-level operation. Gain, low noise amplification, at this time the signal output by IC2 pin ① is strong enough. IC3 is used as a voltage comparator. Its ⑤ pin is provided with the reference voltage by R10 and VD1. When the signal voltage output by IC2 ① pin reaches the ⑥ pin of IC3, the voltages of the two input terminals are compared. At this time, the ⑦ pin of IC3 is changed from the original High level becomes low level. IC4 is an alarm delay circuit, R14 and C6 form a delay circuit, and its time is about 1 minute. When IC3's ⑦ pin becomes low level, C6 is discharged through VD2. At this time, IC4's ② pin becomes low level. It is compared with the IC4's ③ pin reference voltage. When it is lower than its reference voltage, IC4's ①The pin changes to high level, VT2 is turned on, and the buzzer BL is energized to sound an alarm. After the infrared signal of the human body disappears, the ⑦ pin of IC3 resumes high-level output, and VD2 is cut off at this time. Since the voltage at both ends of C6 cannot suddenly change, C6 is slowly charged through R14. When the voltage at both ends of C6 is higher than its reference voltage, the ① pin of IC4 changes to low level for about 1 minute, that is, the alarm continues for 1 minute. .
The power-on delay circuit is composed of VT3, R20, and C8 , and the time is about 1 minute. Its setting is mainly to prevent the user from alarming immediately after powering on, so that the user has enough time to leave the monitoring site, and at the same time, it can prevent the user from restarting after a power outage. A false alarm is generated during an incoming call.
The device is powered by 9-12V DC power supply, which is step-down by T, full-bridge U rectifier, C10 filter, and the detection circuit is powered by IC5 78L06. This device can be used for both AC and DC, with automatic and uninterrupted conversion.
During production, a Fresnel lens is installed in front of the end of the IC 1 sensor. Because the human body's activity frequency range is 0.1-10Hz, a Fresnel lens needs to be used to multiply the human body activity frequency.
If the installation is correct, connect the power supply for debugging, let a person walk 7-10m in front of the detector, adjust R12 in the circuit, and make the sounder alarm. As long as the components are of good quality and the welding is correct, other parts can work normally without debugging.
The static working current of this machine is about 10mA. It will enter the waiting state about 1 minute after the power is turned on. As long as someone enters the monitoring area, it will alarm. It will stop alarming about 1 minute after the person leaves. If the buzzer is changed to a relay to drive other devices, it can be used for other controls.
- A small improvement on the ordinary refrigerator motor starting circuit
- Using P110C to control 6 DC motors simultaneously
- Design and production of radio remote control fan stepless speed regulator
- Hydraulic control circuit design and analysis
- Amplitude and phase detection leakage protection device designed and manufactured using PIC16C711A
- Infrared blocking alarm device
- Infrared detection alarm
- Disconnection anti-theft protection circuit
- Voltage regulation and timing dual-purpose controller
- Refrigerator Thermostat Replacement Device
- Normally closed contact anti-theft alarm circuit diagram
- Touch alarm circuit for coronary heart disease patients
- One of the delay circuits using 555 time base integrated circuit
- One of the thyristor turn-on delay circuits
- Thyristor cut-off delay circuit 6
- Conductive tube controlled charging delay circuit
- Connection of music alarm detection components
- Electric contact mercury thermometer constant temperature control circuit 3a
- Linear infrared anti-theft alarm circuit
- transistor long delay circuit