Home > Optoelectronic Circuits >Optoelectronic Display Circuits > SS0614 touch stepless dimming light circuit

SS0614 touch stepless dimming light circuit

Source: InternetPublisher:武林萌主 Keywords: Stepless dimming touch type dimming lamp Updated: 2020/02/17

148.SS0614<strong>Touch type</strong><strong>Stepless dimming</strong>Lamp<strong>Circuit</strong>.gif

Adopt SS. Countless dimming lights made of 614 integrated circuits also adopt a "one-line" connection method, which
can directly replace ordinary switches without changing the original indoor wiring. Touch the M button to make the voltage at both ends of the bulb
continuously adjustable between 27-200V.
    SS0614 shock absorber is manufactured
with silicon gate CMOS
process, standard
DIP-8 package,
the functions of each pin
are: ① pin V r, n,
the positive terminal of the power supply; ②
pin is the dimming control
terminal, and sending pulses at this terminal
can make the AC
output The effective voltage
value gradually decreases until it reaches . ; ③Pin is the internal phase-locked loop} U filter connected to the capacitor end; ④Pin is the grid voltage
sampling end; ⑤Pin is the touch signal input end; @Pin and ⑦Pin are both Vss, lu source negative end ; ⑧Pin is a twisted
pulse output terminal to control the conduction angle of the gate tube. The power supply voltage range used by SS061-1 is the same as 45~W.
    When in use, briefly touching M with your finger (the touch time is less than 33'/ms) can
control the light F "off" or "off"; when the touch time is greater than 332rrt, the light brightness will increase from small to large. When the touch screen changes
, the scanning period is 4 s. Stop touching and the light brightness will be fixed. At this brightness, short touch M. Turn off the light
, and the originally set brightness will be memorized by the integrated block. When the light is changed to short touch M, the bulb will
light up at this brightness. When the circuit is connected to the power supply, the phase and neutral lines must be as shown in the figure. Standard wiring, if hung upside down, cannot be
touched frequently, but it will not damage any equipment.


EEWorld
subscription