MODEL TL-5955
International size reference: 2/3AA, ER14335
TECHNICAL DATA
(Typical values @+ 25ºC for batteries stored for one year or less)
Nominal capacity @ 1.3 mA, to 2 V
1.5 Ah
Rated voltage
3.6 V
Maximum recommended continuous current
75 mA
Maximum pulse current capability
150 mA
Weight
12.5 g (0.441 oz)
Volume
5.2 cc
Operating temperature range
-55 ºC to +85 ºC
Li metal content
approx. 0.5 g
U.L. Component Recognition, MH 12193
Volts
4.0
DISCHARGE CHARACTERISTICS @ +25ºC
3.5
3.0
2.5
2.0
154
Ω
~20 mA
(1.20 Ah)
1 kΩ
2.7 kΩ
~3.3 mA ~1.3 mA
(1.50Ah) (1.50 Ah)
17 kΩ
~0.2 mA
(1.50 Ah)
60 kΩ
227 kΩ
~60
µA
~16
µA
(1.45 Ah) (1.20 Ah)
1.5
TERMINATIONS & ORDERING NO.
SUFFIX- /S STANDARD
15-5955-21500
15-5955-31500
15-5955-41500
15-5955-36500
15-5955-52500
15-5955-53500
SUFFIX- /T SOLDER TABS
SUFFIX- /P AXIAL PINS
1.0
1
10
100
1000
10000
100000
Hours
SUFFIX- /PT2 RADIAL PINS
SUFFIX- /TP POLARIZED TABS
SUFFIX- /PT POLARIZED TABS
Volts
3.7
3.5
VOLTAGE VS. TEMPERATURE
Ah
CAPACITY VS. CURRENT
-30 °C
1.5
5
µA
3.3
3.1
2.9
2.7
-50
21
µA
1 mA
1.2
25 °C
0.9
55 °C
2.5 mA
5 mA
17 mA
0.6
0.3
-30
-10
10
30
50
70
90
ºC
72 °C
0.01
0.1
1
10
mA
iXtra - Long Term High Performance
Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as
warranties either expressed or implied, of future performance.
ECN 1501879
Rev. D 11/08
Page 1 of 2
TL-5955
CELL FEATURES
3.6 V Primary lithium-thionyl chloride (Li-SOCl2)
Fast voltage recovery after long term storage and/or usage
High energy density
High and stable operating voltage
Low self discharge rate
Bobbin construction
Hermetic glass-to-metal-sealing
Non-flammable electrolyte
MAIN APPLICATIONS
Utility meters (elect., water &
gas)
Automatic meter reading
RF systems
Sensors & monitoring systems
Tracking systems
Wireless security systems
Automotive electronics
Industrial electronics
Ultra Low Power (ULP)
Volts
3.5
3.4
3.3
3.2
3.1
3.0
2.9
2.8
2.7
2.6
0
VOLTAGE RESPONSE AFTER STORAGE
After 1 year
After 2 years
After 5 years
After 10 years
STORAGE CONDITIONS
Cells should be stored in a
clean & dry (less than 30 %
RH) area
Pulse applied: 15 mA for 1 sec
Storage: RT
Background current: None
200
400
600
800
1000
1200
msec
For updated information please visit
our website
www.tadiranbat.com
Volts
3.5
VOLTAGE RESPONSE
After 1 year
After 5 years
Volts
3.5
VOLTAGE RESPONSE
After 5 years
After 1 year
After 7 years
3.4
3.4
3.3
After 10 years
3.3
After 2 years
3.2
Pulse applied: 15 mA for 100 msec
Temperature: RT
Background current: 7.5
µA
0
20
40
60
80
100
120
msec
3.2
Pulse applied: 15 mA for 100 msec
Temperature: RT
Background current: 15
µA
0
20
40
60
80
100
120
msec
3.1
3.1
iXtra - Long Term High Performance
Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as
warranties either expressed or implied, of future performance.
ECN 1501879
Rev. D 11/08
Page 2 of 2