Product data sheet
Characteristics
XVEL6B4
RED STROBE BEACON INTEGRAL LED
24VAC/DC
Product availability: Non-Stock - Not normally stocked in distribution facility
Main
Commercial Status
Range of product
Product or component
type
Beacon/Indicator bk
unit type
Commercialised
Harmony XVE Optimum
Complete illuminated beacon
1 short fixing base
1 screw fixing cover
1 illuminated unit
1 base unit
Flashing
XVE
Red integral flash discharge tube
24 V AC/DC
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Signalling type
Component name
Light source
Bulb type
[Us] rated supply
voltage
Flash discharge tube
Complementary
Mounting diameter
Flash energy
Connections - terminals
Marking
Overld and short-circuit prot
[Ui] rated insulation voltage
Nominal voltage limit
Current consumption
[Uimp] rated impulse withstand voltage
Flashing frequency
CAD overall width
CAD overall height
CAD overall depth
Terminals description ISO n°1
Product weight
2.76 in (70 mm)
1J
Screw clamp terminals: <= 1 x 1.5 mm² with cable end
CE
0.63 A
250 V conforming to IEC 60947-1
0.85...1.1 Un conforming to IEC 60947-5-1
< 85 mA DC
< 145 mA AC
4 kV conforming to IEC 60947-1
1 Hz
2.76 in (70 mm)
5.08 in (129 mm)
2.76 in (70 mm)
(COM-1)PW
(GND)GROUND
0.6 lb(US) (0.27 kg)
Environment
Standards
Product certifications
EN/IEC 60947-1
EN/IEC 60947-5-1
CCC
CSA
UL
-40...158 °F (-40...70 °C)
-13...131 °F (-25...55 °C)
Class I plastic tube mounting conforming to IEC 61140
Class I aluminium tube mounting conforming to IEC 61140
TC
IP42 in vertical position conforming to IEC 60529
IP40 in any position except vertical position conforming to IEC 60529
Ambient air temperature for storage
Ambient air temperature for operation
Class of protection against electric shock
Protective treatment
IP degree of protection
Mar 1, 2016