EEWORLDEEWORLDEEWORLD

Part Number

Search

ADA750F-30-W

CategoryPower/power management   
File Size746KB,7 Pages
ManufacturerCosel
Download Datasheet Parametric View All

ADA750F-30-W Online Shopping

Suppliers Part Number Price MOQ In stock  
ADA750F-30-W - - View Buy Now

ADA750F-30-W Parametric

Parameter NameAttribute value
Product CategorySwitching Power Supplies
ManufacturerCosel
RoHSDetails
ProductSwitching Supplies
Output Voltage-Channel 124 V
Number of Outputs1 Output
Output Power750 W
Input Voltage85 VAC to 264 VAC/120 VDC to 350 VDC
Output Current-Channel 131.5 A
Commercial/MedicalCommercial
Isolation Voltage3 kV
Mounting StyleChassis
Length230 mm
Width127 mm
Height70 mm
Input Frequency50 Hz/60 Hz
Load RegulationRegulated
Factory Pack Quantity5
Unit Weight4.189 lbs
AC-DC Power Supplies Enclosed Type
Ordering information
ADA
ADA
R
ADA600F
ADA 600
1
2
3
F
4
-24
5
-O
1Series
name
2Output
wattage
3Universal
input
4Output
voltage
5Optional
*7
G :Low leakage current
E :Low leakage current
and EMI class A
F :with Fan unit
T :Vertical terminal block
J :Connector type
C :with Coating
R :Remote ON/OFF
N1:DIN rail
W:Alarms and Redundant
operation
Specification is changed at
option,refer to Instruction
Manual.
Recommended EMI/EMC Filter
NAC-20-472
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*The
EMI/EMC Filter is recommended
*to
connect with several devices.
Please refer to derating curve, because the rated load current depends on cooling method that is convection cooling or forced air.
SPECIFICATIONS
MODEL
VOLTAGE[V]
FREQUENCY[Hz]
ACIN 100V
ACIN 200V
ACIN 100V
INPUT
POWER FACTOR
ACIN 200V
ACIN 100V
*
1
INRUSH CURRENT[A]
ACIN 200V
*
1
LEAKAGE CURRENT[mA]
VOLTAGE[V]
ACIN 100V
*
2
ACIN 100V
*
2
CURRENT[A]
ACIN 200V
*
2
ACIN 200V
*
2
LINE REGULATION[mV]
LOAD REGULATION[mV]
0 to +50
C
*
3
RIPPLE[mVp-p]
OUTPUT
-10 - 0
C
*
3
0 to +50
C
*
3
RIPPLE NOISE[mVp-p]
-10 - 0
C
*
3
TEMPERATURE REGULATION[mV] 0 to +50
C
*
4
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
PROTECTION OVERVOLTAGE PROTECTION[V]
CIRCUIT AND OPERATING INDICATION
OTHERS
ALARM OUTPUT
REMOTE ON/OFF(RC)
EFFICIENCY[%]
ADA600F-24
ADA600F-30
ADA600F-36
AC85 - 264 1
f
or DC 120 - 350 (AC64 or DC90 optionally available
*
6)
50/60 (47 - 63) or DC
84typ (Io=100%)
86typ (Io=100%)
86typ (Io=100%)
86typ (Io=100%)
87typ (Io=100%)
87typ (Io=100%)
0.99typ (Io=100%)
0.98typ (Io=100%)
20typ (Io=100%) (More than 3sec.to re-start)
40typ (Io=100%) (More than 3sec.to re-start)
0.75max (60Hz, According to IEC60950 and DEN-AN) (Io=100%)
ADA600F-48
86typ (Io=100%)
89typ (Io=100%)
24
30
36
48
14 (Peak 25) convection
11 (Peak 20) convection
9 (Peak 16.5) convection
6.5 (Peak 12.5) convection
21 (Peak 25) forced air
16.5 (Peak 20) forced air
14 (Peak 16.5) forced air
10.5 (Peak 12.5) forced air
15 (Peak 31) convection
12 (Peak 24.5) convection 10 (Peak 20.5) convection 7 (Peak 15.5) convection
25 (Peak 31) forced air
20 (Peak 24.5) forced air
16.5 (Peak 20.5) forced air 12.5 (Peak 15.5) forced air
96max
120max
144max
192max
150max
180max
240max
300max
120max
160max
200max
200max
160max
230max
260max
300max
150max
190max
230max
250max
180max
250max
280max
400max
240max
300max
360max
480max
96max
120max
144max
192max
500max (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
21.6 - 27.0
27.0 - 33.0
33.0 - 41.0
41.0 - 52.8
23.5 - 24.5
29.0 - 31.0
35.0 - 37.0
47.0 - 49.0
Works over 101% of peak current and recovers automatically
31 - 34.5
40 - 48
51 - 60
64 - 76
LED (Green)
Detecting low input voltage(PF), detecting low output voltage(LV). (Optional : -W, refer to Instruction Manual 5)
Requirement for external source (Option : -R, refer to Instruction Manual 5)
*
5
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
INPUT-OUTPUT
-
RC
ISOLATION INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
5
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
*
OUTPUT
-
RC-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +71
C
, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
ENVIRONMENT
VIBRATION
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input)
SAFETY AND AGENCY APPROVALS
NOISE
CONDUCTED NOISE
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
REGULATIONS HARMONIC ATTENUATOR
Complies with IEC61000-3-2
*
8
CASE SIZE/WEIGHT
65
X
127
X
195mm [2.56
X
5
X
7.68 inches] (W
X
H
X
D) (without terminal block) /1.5kg max
OTHERS
COOLING METHOD
Convection/Forced air
*1
The value is primary surge.The current of input surge to a built-in EMI/EMC Filter (0.2ms or
less) is excluded.
*2
Peak loading for 10sec.And Duty 35% max.Refer to Instruction Manual 4.Forced air is shown
in Instruction Manual 2.3.
*3
This is the value that measured on measuring board with capacitor of 22mF within 150mm
from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to
KEISOKU-GIKEN: RM101).
*4
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
*5
Applicable when remote control (optional) is added.
*6
Derating is required.Consult us for details.
*7
Please contact us about safety approvals for the model with option.
*8
Please contact us about class C.
*
A sound may occur from power supply at pulse loading.
ADA-2
About the power consumption optimization design in embedded DSP design
Optimizing power consumption is an important but often elusive design goal for digital signal processor (DSP)-based systems. Today, DSP-based devices often combine multiple applications that were prev...
Jacktang Microcontroller MCU
About the peripheral circuit of single chip microcomputer to measure the frequency of alternating current
I want to measure the frequency of the AC power generated by the generator through a single-chip microcomputer. The basic idea is: transformer step-down - diode half-wave rectification - Schmitt trigg...
xhd1099924128 Analog electronics
Static Timing Analysis Basics and Applications
...
至芯科技FPGA大牛 FPGA/CPLD
How much do you know about the performance improvement of Wi-Fi 6 routers?
Compared to similar products, FEMs offer 40% greater energy efficiency and 20% greater coverage, and FEM products can advance connectivity by increasing the number of connected devices by 4 times at h...
alan000345 RF/Wirelessly
What is the problem with amplifier instability?
The in-phase voltage amplifier of the circuit below is unstable. When testing the transmission line at J8, the output of the first opa855 oscillates. When the input is suspended, the output is 70MHZ w...
灞波儿奔 Power technology
【RPi PICO】Breathing light
Most of the RPi PICO pins support PWM, which can easily achieve the breathing light effect.from machine import Pin, Timer, PWMLED = PWM(Pin(25))n = 0def breathing(t):global nLED.duty_u16(abs(32000- n*...
dcexpert MicroPython Open Source section

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2024 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号