Railway/Transportation system applications including communications systems, informa-
tion display, lighting, control systems, ticket machines, passenger
entertainment, public address systems, door control, industrial power systems and power
generation systems.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Product Overview
These DC-DC converter modules use
advanced power processing, control and
packaging technologies to provide the
performance, flexibility, reliability and cost
effectiveness of a mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V110C12C100BL
110C
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
=
- 10 to +100
- 20 to +125
C
=
- 20 to +100
- 40 to +125
T
=
- 40 to +100
- 40 to +125
H
=
- 40 to +100
- 55 to +125
M
=
- 55 to +100
- 65 to +125
B
Output Power
V
OUT
P
OUT
3.3V
50W
5V
75W, 125W
8V
75W
12V
100W
15V
100W, 150W
24V
100W, 150W
28V
100W
36V
100W
48V
100W, 150W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Product Type
V
= Standard
S
= Enhanced
efficiency
(avail.
≤12
V
OUT
only)
Output Voltage
3V3
= 3.3V
5
= 5V
8
= 8V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
36
= 36V
48
= 48V
110V Micro Family
Page 1 of 13
Rev 4.1
06/2017
vicorpower.com
800 927.9474
110V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
54
155.5
64
56
161.7
169.4
1.3
Min
66
Typ
110
Max
154
250
65.4
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
Notes
Per EN50155 and GBT-25119
<100ms
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1
±0.20
±0.005
±5
110
Unit
%
%
% / °C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to –OUT — Absolute Maximum Ratings
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
–0.5 to 4.7
–0.5 to 7.0
–0.5 to 10.9
–0.5 to 16.1
–0.5 to 20.0
–0.5 to 31.7
–0.5 to 36.9
–0.5 to 47.4
–0.5 to 62.9
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 8.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20265)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.24
0.21
10.9
2.8
48
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
110V Micro Family
Page 2 of 13
Rev 4.1
06/2017
vicorpower.com
800 927.9474
110V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
Switch must be able to sink
≥4mA.
See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
Temperature limiting
Agency approvals
1.9
(52.8)
2.1
(58.7)
100
Min
3000
1500
500
10
2.1
(59.3)
2.3
(65.2)
115
cURus, cTÜVus, CE
2.3
(65.8)
2.5
(71.7)
Typ
Max
Unit
V
RMS
V
RMS
V
RMS
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
110V Micro Family
Page 3 of 13
Rev 4.1
06/2017
vicorpower.com
800 927.9474
110V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
3.3V
OUT
, 50W (e.g. S110C3V3C50BL, V110C3V3C50BL)
Parameter
Efficiency
S110C3V3C50BL (enhanced efficiency)
V110C3V3C50BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
81.0
78.8
4.14
Typ
85.0
79.8
124
4.3
1.7
±0.02
17.5
17.5
Max
Unit
%
157
4.46
2.7
±0.2
15.15
20.6
20.6
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
15.5
10.6
5V
OUT
, 125W (e.g. S110C5C125BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.0
6.03
Typ
86.8
120
6.25
3.1
±0.02
28.8
28.8
Max
150
6.47
6.2
±0.2
25
33.8
33.8
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
25.5
17.5
5V
OUT
, 75W (e.g. S110C5C75BL, V110C5C75BL)
Parameter
Efficiency
S110C5C75BL (enhanced efficiency)
V110C5C75BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.9
82.6
6.03
Typ
86.5
83.6
92
6.25
3.3
±0.02
17.3
17.3
Max
Unit
%
115
6.47
5.4
±0.2
15
20.3
20.3
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
15.3
10.5
8V
OUT
, 75W (e.g. S110C8C75BL, V110C8C75BL)
Parameter
S110C8C75BL (enhanced efficiency)
V110C8C75BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
85.5
83.0
9.36
Typ
87.5
84.3
280
9.7
2.6
±0.02
10.8
10.8
Max
Unit
%
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
9.56
6.56
350
10.1
3.5
±0.2
9.38
12.7
12.7
mV
Volts
Watts
%
Amps
Amps
Amps
110V Micro Family
Page 4 of 13
Rev 4.1
06/2017
vicorpower.com
800 927.9474
110V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
12V
OUT
, 100W (e.g. S110C12C100BL, V110C12C100BL)
Parameter
Efficiency
S110C12C100BL (enhanced efficiency)
V110C12C100BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
88.2
87.0
13.7
Typ
89.5
88.2
150
14.3
3.1
±0.02
9.58
9.58
Max
Unit
%
188
14.9
5.1
±0.2
8.33
11.3
11.3
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
8.49
5.83
15V
OUT
, 150W (e.g. S110C15C150BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.7
17.1
Typ
88.2
140
17.8
5.5
±0.02
11.5
11.5
Max
175
18.5
7.5
±0.2
10
13.5
13.5
Unit
%
mV
Volts
Watts
%
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
0
10.2
7.0
15V
OUT
, 100W (e.g. V110C15C100BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.5
17.1
Typ
84.5
100
17.8
4
±0.02
7.67
7.67
Max
125
18.5
5
±0.2
6.67
9.01
9.01
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
6.8
4.66
24V
OUT
, 150W (e.g. V110C24C150BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
87.2
27.2
Typ
88.7
131
28.2
4.6
±0.02
7.2
7.2
Max
164
29.2
6.0
±0.3
6.25
8.4
8.4
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwith
25°C; recycle input voltage or PC to restart (>100ms off)
[size=4] [md]## Preface In the previous article, we simulated speed data through light sensor data, and used online IDE to complete data collection and synchronous display. We experienced the quick de...
Reward post, asking for help from the big guys hidden in the forum, is there any big guy who has a sufficient level of DSP and can teach and solve related problems? It is equivalent to hiring a master...
We can see various capacitors in the power supply filter circuit, with different capacitance values of 100uF, 10uF, 100nF, and 10nF. So how are these parameters determined?For digital circuits to run ...
[size=4]The source code of the microcontroller is as follows:[/size] [size=4]/**[/size] [size=4]******************************************************************************[/size] [size=4]* @file FD...
Introduction to AND Gate Circuits From small electronic watches to complex electronic computers, many of their components are made into integrated circuits, that is, dozens, hundreds, or even tens of...